Oscillometric blood pressure measurement: Description of the method used

被引:0
|
作者
Wonka, F
机构
来源
关键词
non-invasive blood pressure measurement; oscillometric blood pressure measurement; development trends; evaluation algorithms; performance and function;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There is no general valid and thus no recognized standard method of evaluation for oscillometric blood pressure measurement. This applies in particular to the determination of blood pressure parameters - systolic, diastolic and mean blood pressure - using a cuff pressure oscillogram. For this reason - and given that today's users are faced with an overwhelming choice of oscillometric blood pressure measuring devices - performance and function are very topical issues. The status and importance of oscillometric blood pressure measurement are inferred from an analysis of trends in the development of non-invasive blood pressure measurement. Oscillometric measurement is described from the point of view of signal analysis, and methods for identifying blood pressure parameters are presented. A check list has been compiled in the form of a questionnaire to help the user assess the performance and function of oscillometric blood pressure measuring devices. Instructions for use are given to avoid handling errors.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] The oscillometric method - A description of the algorithm used by 24-hour ambulatory blood pressure monitors
    Mieke, S
    [J]. NIEREN-UND HOCHDRUCKKRANKHEITEN, 1996, 25 (08) : 341 - 342
  • [2] Oscillometric blood pressure measurement used for calibration of the arterial tonometry method contributes significantly to error
    Hansen, S.
    Staber, Bl.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (09) : 781 - 787
  • [4] A New Noise Reduction Method for Oscillometric Blood Pressure Measurement
    Choi, Hyun-Seok
    Myoung, Hyoun-Seok
    Lee, Hyo-Ki
    Park, Ho-Dong
    Lee, Kyoung-Joung
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 270 - +
  • [5] A New Algorithm of Blood Pressure Measurement Based on Oscillometric Method
    Luo, Cong
    Li, Tingyu
    Quan, Xiaoli
    Gu, Liangling
    Zhao, Mingfu
    [J]. 2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1710 - +
  • [6] Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement
    Yarows, SA
    Patel, K
    Brook, R
    [J]. BLOOD PRESSURE MONITORING, 2001, 6 (03) : 145 - 147
  • [7] A new methodology of blood pressure measurement through the oscillometric method
    Chabane, Lilia
    Tahar, Omari
    Benlatreche, Mohamed Salah
    Bereksi-Reguig, Fethi
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (10)
  • [8] STANDARD ALGORITHM OF BLOOD-PRESSURE MEASUREMENT BY THE OSCILLOMETRIC METHOD
    YAMAKOSHI, K
    TANAKA, S
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (02) : 204 - 204
  • [9] Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement
    Yarows, SA
    Patek, K
    Brook, R
    [J]. JOURNAL OF HYPERTENSION, 2000, 18 : S55 - S56
  • [10] OSCILLOMETRIC MEASUREMENT OF ARTERIAL BLOOD PRESSURE
    BENSON, H
    HERD, JA
    [J]. CIRCULATION, 1969, 40 (4S3) : II43 - &