Effect of clothing on sphygmomanometric and oscillometric blood pressure measurement in hypertensive subjects

被引:8
|
作者
Eder, M. J. C. [1 ]
Holzgreve, H. [2 ]
Liebl, M. E. [3 ]
Bogner, J. R. [1 ]
机构
[1] Univ Munich, Klinikum Innenstadt, Med Poliklin, D-80336 Munich, Germany
[2] Kardiol Praxis, Munich, Germany
[3] Abt Orthopad, Med Klin, Berlin, Germany
关键词
hypertension; blood pressure measurement; oscillometry; sphygmomanometry; clothes;
D O I
10.1055/s-2008-1077254
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objective: The few studies published on this subject have shown that blood pressure measurements give similar results whether the patients' arm is covered by clothing or not. But it has not been clarified whether this is also true in the case of hypertensive persons, Yet, in practice the correct measurement is of critical importance in the diagnosis of hypertension. Methods: 203 hypertensive patients were examined with the auscultatory sphygmomanometry and the automatic oscillometry by measuring the pressure three times with each method. These tests were carried out in a randomized sequence on a covered arm (the patient's own clothing of maximally 2 mm thickness), the bare arm and the arm covered with a standardized cotton sleeve (2 mm). The auscultatory sphygmomanometry was done blinded (non-sleeved, sleeved, standardized). Results: Calculation of confidence intervals for the mean differences of the three settings (bare, clothing and standard sleeve) and equivalence testing demonstrated that a garment or cloth on the arm under the manometer cuffs did not significantly effect the blood pressure within the predefined interval of equivalence of 4 mm Hg. Thus, measuring blood pressure with the cuff over the person's sleeve does not significantly effect the result. Conclusion: This study shows that measuring blood pressure in hypertensive persons with or without a cloth sleeve (maximally 2 mm thick) does not result in any statistically significant difference. This simplifies the blood pressure measurement that have to be taken frequently on hypertensive persons.
引用
收藏
页码:1288 / 1292
页数:5
相关论文
共 50 条
  • [21] The oscillometric blood pressure measurement - mathematical modeling
    Juroszek, Barbara
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (12): : 304 - 307
  • [22] Oscillometric blood pressure measurement: progress and problems
    van Montfrans, GA
    BLOOD PRESSURE MONITORING, 2001, 6 (06) : 287 - 290
  • [23] Automated Oscillometric Blood Pressure Measurement in Children
    Chiolero, Arnaud
    Bovet, Pascal
    Stergiou, George S.
    JOURNAL OF CLINICAL HYPERTENSION, 2014, 16 (06): : 468 - 468
  • [24] COMPARISON OF INTRAARTERIAL AND AUTOMATED OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENT METHODS IN POSTOPERATIVE HYPERTENSIVE PATIENTS
    LOUBSER, PG
    MEDICAL INSTRUMENTATION, 1986, 20 (05): : 255 - 259
  • [25] Comparison of a wrist cuff oscillometric blood pressure measurement device with an upper arm-cuff oscillometric device in obese subjects
    de Senarclens, Olivier
    Feihl, Francois
    Giusti, Vittorio
    Engelberger, Rolf P.
    Rodieux, Frederique
    Gomez, Patrick
    Liaudet, Lucas
    Waeber, Bernard
    JOURNAL OF HYPERTENSION, 2006, 24 : 173 - 173
  • [26] The Effect of Clothes on Blood Pressure Measurement in Normotensive and Hypertensive Subjects in a Real-Life Setting
    Velarde, Edwin Castillo
    Roca-Sanchez-Moreno, Jorge
    Munoz, Alison Nunez
    Rivera, Alessandra Guillen
    Babilonia, Mary Hidalgo
    Meneses, Jherson Garcia
    Turpo, Lisseth Mamani
    Horna, Willian Cepeda
    KIDNEY & BLOOD PRESSURE RESEARCH, 2024, 49 (01): : 295 - 301
  • [27] Self measurement of blood pressure contribute to improve the education of hypertensive subjects
    Hanon, O
    Mourad, JJ
    Mounier-Vehier, C
    Laria, P
    Fauvel, JP
    Marquand, A
    Dimitrov, Y
    Girerd, X
    JOURNAL OF HYPERTENSION, 2001, 19 (08) : A19 - A19
  • [28] Self measurement of blood pressure contributes to improve the education of hypertensive subjects
    Hanon, O
    Mourad, JJ
    Mounier-Vehier, C
    Iaria, P
    Fauvel, JP
    Marquand, A
    Dimitrov, Y
    Girerd, X
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2001, 94 (08): : 879 - 883
  • [29] COMPARISON OF BLOOD-PRESSURE MEASUREMENTS BY SEMIAUTOMATIC CUFF-OSCILLOMETRIC AND SPHYGMOMANOMETRIC MICROPHONE METHODS WITH INTRAARTERIAL VALUES
    KLAUS, D
    WETZCHEWALD, D
    SAUL, F
    OBERMEIER, G
    LAMBERS, F
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1991, 20 (04) : 160 - 169
  • [30] Clothing and blood pressure measurement precision
    Ishak, Anthony
    Juraschek, Stephen P.
    Cluett, Jennifer
    JOURNAL OF HYPERTENSION, 2021, 39 (02) : 381 - 382