Performance of cone beam CT using a flat-panel imager

被引:1
|
作者
Endo, M [1 ]
Tsunoo, T [1 ]
Satoh, K [1 ]
Matsusita, S [1 ]
Kusakabe, M [1 ]
Fukuda, Y [1 ]
机构
[1] Natl Inst Radiol Sci, Chiba 2638555, Japan
关键词
cone beam CT; flat-panel imager; image characteristics; scatter rejection;
D O I
10.1117/12.430960
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An active matrix flat-panel imager (FPI) is a good candidate for the 2-dimensional detector of cone beam CT (CBCT), because it has a wider dynamic range and less geometrical distortion than video-fluoroscopic system so far employed. However the performance of FPI-based CBCT has not been sufficiently examined yet. The aim of this work is to examine the performance of CBCT using a FPI with several phantoms. An X-ray tube, a phantom and a FPI were aligned on an experimental table. The FPI was PaxScan2520 provided by Varian Medical Systems. It has an active area of approximately 180x240mm and the pixel size is 127 micrometer. Csl is used as a scintillator. The phantom was rotated with I-degree steps while 360 projection frames (1408x1888 active pixels each frame) were collected. 2x2 pixels were combined into a single pixel to reduce noise. 512x512x512 voxels were reconstructed with the Feldkamp method. The comparison was made between reconstructed images with or without scatter rejecting grid. The uniformity and linearity of reconstruction value was drastically improved with the grid. Scatter rejection using a thin-vane collimator was also examined, and it showed more effective than the grid.
引用
收藏
页码:815 / 821
页数:7
相关论文
共 50 条
  • [1] Microcalcification detection using cone-beam CT mammography with a flat-panel imager
    Gong, X
    Vedula, AA
    Glick, SJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2183 - 2195
  • [2] A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    Groh, BA
    Siewerdsen, JH
    Drake, DG
    Wong, JW
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 967 - 975
  • [3] Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    Jaffray, DA
    Siewerdsen, JH
    [J]. MEDICAL PHYSICS, 2000, 27 (06) : 1311 - 1323
  • [4] Cone-beam computed tomography on a medical linear accelerator using a flat-panel imager
    Jaffray, DA
    Siewerdsen, JH
    Groh, B
    Drake, DG
    Wong, JW
    Martinez, AA
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 558 - 560
  • [5] Computer simulation of CT mammography using a flat-panel imager
    Vedula, AA
    Glick, SJ
    Gong, X
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 349 - 360
  • [6] Lag correction for flat-panel cone-beam CT in SPECT/CT
    Wang, Jiong
    Hansis, Eberhard
    van de Haar, Peter
    Sowards-Emmerd, David
    Bredno, Joerg
    Shao, Lingxiong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [7] Performance of a volumetric CT scanner based upon a flat-panel imager
    Jaffray, DA
    Siewerdsen, JH
    Drake, DG
    [J]. MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 204 - 214
  • [8] Cone-beam computed tomography with a flat-panel imager: Effects of image lag
    Siewerdsen, JH
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 1999, 26 (12) : 2635 - 2647
  • [9] Geometric Calibration of Cone-beam CT with a Flat-panel Detector
    Wu, Dufan
    Li, Liang
    Zhang, Li
    Xing, Yuxiang
    Chen, Zhiqiang
    Xiao, Yongshun
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2952 - 2955
  • [10] Using a flat-panel detector in high resolution cone beam CT for dental imaging
    Baba, R
    Ueda, K
    Okabe, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) : 285 - 290