Microcalcification detection using cone-beam CT mammography with a flat-panel imager

被引:69
|
作者
Gong, X [1 ]
Vedula, AA [1 ]
Glick, SJ [1 ]
机构
[1] Univ Massachusetts, Dept Radiol, Sch Med, Worcester, MA 01655 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 11期
关键词
D O I
10.1088/0031-9155/49/11/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to investigate microcalcification delectability using CT mammography with a flat-panel imager. To achieve this, a computer simulation was developed to model an amorphous-silicon, CsI based flat-panel imager system using a linear cascaded model. The breast was modelled as a hemi-ellipsoid shape with composition of 50% adipose and 50% glandular tissue. Microcalcifications were modelled as small spheres having a composition of calcium carbonate. The results show that with a mean glandular dose equivalent to that typically used in two-view screening mammography, CT mammography with a flat-panel detector is capable of providing images where most microcalcifications are detectable. A receiver operating characteristic (ROC) study was conducted by five physicist observers viewing simulated CT mammography reconstructions. The results suggest that the microcalcification with its diameter equal to or greater than 0.175 mm can be detected with an average area under the ROC curve (AUC) greater than 0.95 using 0.1 or 0.2 mm pixelized detectors. The results also indicate that the optimal pixel size of the detector is around 0.2 mm for microcalcification detection, based on the trade-off between detectability of microcalcifications and the time required for data acquisition and reconstruction.
引用
收藏
页码:2183 / 2195
页数:13
相关论文
共 50 条
  • [1] Performance of cone beam CT using a flat-panel imager
    Endo, M
    Tsunoo, T
    Satoh, K
    Matsusita, S
    Kusakabe, M
    Fukuda, Y
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 815 - 821
  • [2] A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    Groh, BA
    Siewerdsen, JH
    Drake, DG
    Wong, JW
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 967 - 975
  • [3] Cone-beam computed tomography on a medical linear accelerator using a flat-panel imager
    Jaffray, DA
    Siewerdsen, JH
    Groh, B
    Drake, DG
    Wong, JW
    Martinez, AA
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 558 - 560
  • [4] Computer simulation of CT mammography using a flat-panel imager
    Vedula, AA
    Glick, SJ
    Gong, X
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 349 - 360
  • [5] Geometric Calibration of Cone-beam CT with a Flat-panel Detector
    Wu, Dufan
    Li, Liang
    Zhang, Li
    Xing, Yuxiang
    Chen, Zhiqiang
    Xiao, Yongshun
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2952 - 2955
  • [6] Lag correction for flat-panel cone-beam CT in SPECT/CT
    Wang, Jiong
    Hansis, Eberhard
    van de Haar, Peter
    Sowards-Emmerd, David
    Bredno, Joerg
    Shao, Lingxiong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [7] Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    Jaffray, DA
    Siewerdsen, JH
    [J]. MEDICAL PHYSICS, 2000, 27 (06) : 1311 - 1323
  • [8] Cone-beam computed tomography with a flat-panel imager: Effects of image lag
    Siewerdsen, JH
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 1999, 26 (12) : 2635 - 2647
  • [9] Simulation of Motion Artifacts in Offset Flat-Panel Cone-Beam CT
    Hansis, Eberhard
    Shao, Lingxiong
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2471 - 2475
  • [10] Using LROC analysis to evaluate detection accuracy of microcalcification clusters imaged with flat-panel CT mammography
    Gong, X
    Glick, SJ
    Vedula, AA
    [J]. MEDICAL IMAGING 2004: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2004, 5372 : 293 - 300