Computer simulation of CT mammography using a flat-panel imager

被引:45
|
作者
Vedula, AA [1 ]
Glick, SJ [1 ]
Gong, X [1 ]
机构
[1] Univ Massachusetts, Sch Med, Worcester, MA 01605 USA
关键词
CT; mammography; simulation; ray-tracing; projection; reconstruction; flat-panel detector;
D O I
10.1117/12.480015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Software has been developed to simulate a cone-beam CT mammography imaging system that consists of an x-ray tube and a flat-panel detector that rotate simultaneously around the pendant breast. The simulation, uses an analytical expression or ray-tracing to generate projection sets of breast phantoms at 1 keV intervals dictated by the input x-ray energy spectra. The x-ray focal spot was modeled as having a Gaussian distribution. The detector was modeled as an amorphous silicon (aSi:H) flat-panel imager that uses a structured CsI scintillator. Noise propagation through the detector was simulated by modeling statistical variations of the projection images at each energy interval as a scaled Poisson process. Scintillator blurring was simulated by using an empirically determined modulation transfer function. After introducing noise and detector blur, projection sets simulated at each energy were then combined and reconstructed using Feldkamp's cone-beam reconstruction algorithm. Using this framework, the effects of a number of acquisition and reconstruction parameters can be investigated. Some examples are shown including the impact of the kVp setting and the number of projection bangles on, the reconstructed image.
引用
收藏
页码:349 / 360
页数:12
相关论文
共 50 条
  • [1] Investigation of optimal kVp settings for CT mammography using a flat-panel imager
    Glick, SJ
    Vedantham, S
    Karellas, A
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 392 - 402
  • [2] Microcalcification detection using cone-beam CT mammography with a flat-panel imager
    Gong, X
    Vedula, AA
    Glick, SJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2183 - 2195
  • [3] Performance of cone beam CT using a flat-panel imager
    Endo, M
    Tsunoo, T
    Satoh, K
    Matsusita, S
    Kusakabe, M
    Fukuda, Y
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 815 - 821
  • [4] Performance of a volumetric CT scanner based upon a flat-panel imager
    Jaffray, DA
    Siewerdsen, JH
    Drake, DG
    [J]. MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 204 - 214
  • [5] Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography
    El-Mohri, Youcef
    Antonuk, Larry E.
    Zhao, Qihua
    Wang, Yi
    Li, Yixin
    Du, Hong
    Sawant, Amit
    [J]. MEDICAL PHYSICS, 2007, 34 (01) : 315 - 327
  • [6] ON RADIOTHERAPY DOSE VERIFICATION WITH A FLAT-PANEL IMAGER
    McDermott, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S49 - S49
  • [7] A comparison of lesion detection accuracy using digital mammography and flat-panel CT breast imaging
    Gong, X
    Vedula, AA
    Thacker, S
    Glick, SJ
    [J]. MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 860 - 869
  • [8] Monte Carlo simulation of a CsI-based flat panel imager for mammography
    Thacker, SC
    Glick, SJ
    Badan, A
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 411 - 419
  • [9] Using LROC analysis to evaluate detection accuracy of microcalcification clusters imaged with flat-panel CT mammography
    Gong, X
    Glick, SJ
    Vedula, AA
    [J]. MEDICAL IMAGING 2004: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2004, 5372 : 293 - 300
  • [10] Patient-Specific Qa for Cyberknife Using a Portable Flat-Panel Imager
    Gersh, J.
    DuBose, R.
    Shay, K.
    Fulkerson, R.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3061 - 3061