Computer simulation of CT mammography using a flat-panel imager

被引:45
|
作者
Vedula, AA [1 ]
Glick, SJ [1 ]
Gong, X [1 ]
机构
[1] Univ Massachusetts, Sch Med, Worcester, MA 01605 USA
关键词
CT; mammography; simulation; ray-tracing; projection; reconstruction; flat-panel detector;
D O I
10.1117/12.480015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Software has been developed to simulate a cone-beam CT mammography imaging system that consists of an x-ray tube and a flat-panel detector that rotate simultaneously around the pendant breast. The simulation, uses an analytical expression or ray-tracing to generate projection sets of breast phantoms at 1 keV intervals dictated by the input x-ray energy spectra. The x-ray focal spot was modeled as having a Gaussian distribution. The detector was modeled as an amorphous silicon (aSi:H) flat-panel imager that uses a structured CsI scintillator. Noise propagation through the detector was simulated by modeling statistical variations of the projection images at each energy interval as a scaled Poisson process. Scintillator blurring was simulated by using an empirically determined modulation transfer function. After introducing noise and detector blur, projection sets simulated at each energy were then combined and reconstructed using Feldkamp's cone-beam reconstruction algorithm. Using this framework, the effects of a number of acquisition and reconstruction parameters can be investigated. Some examples are shown including the impact of the kVp setting and the number of projection bangles on, the reconstructed image.
引用
收藏
页码:349 / 360
页数:12
相关论文
共 50 条
  • [11] Relative dosimetry using active matrix flat-panel imager (AMFPI) technology
    El-Mohri, Y
    Antonuk, LE
    Yorkston, J
    Jee, KW
    Maolinbay, M
    Lam, KL
    Siewerdsen, JH
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1530 - 1541
  • [12] Evaluation of a hybrid direct-indirect active matrix flat-panel imager using Monte Carlo simulation
    Dow, Scott
    Howansky, Adrian
    Lubinsky, Anthony R.
    Zhao, Wei
    [J]. JOURNAL OF MEDICAL IMAGING, 2020, 7 (03)
  • [13] Flat-panel imager utilizing a-Si array technology
    Teranuma, O
    Izumi, Y
    Takahashi, M
    Sato, T
    Uehara, K
    Okada, H
    Yamane, Y
    [J]. IEICE TRANSACTIONS ON ELECTRONICS, 2004, E87C (11) : 1948 - 1953
  • [14] Se-based flat-panel detector for screening mammography
    Polischuk, B
    Savard, S
    Loustauneau, V
    Hansroul, M
    Cadieux, S
    Vaqué, A
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 582 - 589
  • [15] Musculoskeletal applications of flat-panel volume CT
    Benjamin Reichardt
    Ammar Sarwar
    Soenke H. Bartling
    Arnold Cheung
    Michael Grasruck
    Christianne Leidecker
    Miriam A. Bredella
    Thomas J. Brady
    Rajiv Gupta
    [J]. Skeletal Radiology, 2008, 37 : 1069 - 1076
  • [16] Musculoskeletal applications of flat-panel volume CT
    Reichardt, Benjamin
    Sarwar, Ammar
    Bartling, Soenke H.
    Cheung, Arnold
    Grasruck, Michael
    Leidecker, Christianne
    Bredella, Miriam A.
    Brady, Thomas J.
    Gupta, Rajiv
    [J]. SKELETAL RADIOLOGY, 2008, 37 (12) : 1069 - 1076
  • [17] The use of flat-panel detectors for CT imaging
    Kalender, WA
    [J]. RADIOLOGE, 2003, 43 (05): : 379 - 387
  • [18] A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    Groh, BA
    Siewerdsen, JH
    Drake, DG
    Wong, JW
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 967 - 975
  • [19] Simulation of Motion Artifacts in Offset Flat-Panel Cone-Beam CT
    Hansis, Eberhard
    Shao, Lingxiong
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2471 - 2475
  • [20] Feasibility of automatic marker detection with an a-Si flat-panel imager
    Nederveen, AJ
    Lagendijk, JJW
    Hofman, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 1219 - 1230