Performance of cone beam CT using a flat-panel imager

被引:1
|
作者
Endo, M [1 ]
Tsunoo, T [1 ]
Satoh, K [1 ]
Matsusita, S [1 ]
Kusakabe, M [1 ]
Fukuda, Y [1 ]
机构
[1] Natl Inst Radiol Sci, Chiba 2638555, Japan
关键词
cone beam CT; flat-panel imager; image characteristics; scatter rejection;
D O I
10.1117/12.430960
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An active matrix flat-panel imager (FPI) is a good candidate for the 2-dimensional detector of cone beam CT (CBCT), because it has a wider dynamic range and less geometrical distortion than video-fluoroscopic system so far employed. However the performance of FPI-based CBCT has not been sufficiently examined yet. The aim of this work is to examine the performance of CBCT using a FPI with several phantoms. An X-ray tube, a phantom and a FPI were aligned on an experimental table. The FPI was PaxScan2520 provided by Varian Medical Systems. It has an active area of approximately 180x240mm and the pixel size is 127 micrometer. Csl is used as a scintillator. The phantom was rotated with I-degree steps while 360 projection frames (1408x1888 active pixels each frame) were collected. 2x2 pixels were combined into a single pixel to reduce noise. 512x512x512 voxels were reconstructed with the Feldkamp method. The comparison was made between reconstructed images with or without scatter rejecting grid. The uniformity and linearity of reconstruction value was drastically improved with the grid. Scatter rejection using a thin-vane collimator was also examined, and it showed more effective than the grid.
引用
收藏
页码:815 / 821
页数:7
相关论文
共 50 条
  • [41] Cone-beam CT with a flat-panel detector: From image science to image-guided surgery
    Siewerdsen, Jeffrey H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S241 - S250
  • [42] Can a Flat Panel Cone Beam CT Imager Pass the American College of Radiology CT Accreditation Requirements for Head Scans?
    Shapiro, E.
    Star-Lack, J.
    Sun, M.
    Tognina, C.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [43] Percutaneous bone biopsy using a flat-panel cone beam computed tomography virtual navigation system
    Liu, Juan-Fang
    Jiao, De-Chao
    Ren, Jian-Zhuang
    Zhang, Wen-Guang
    Han, Xin-Wei
    [J]. SAUDI MEDICAL JOURNAL, 2018, 39 (05) : 519 - 523
  • [44] Office-based cone-beam and digital tomosynthesis systems using flat-panel technology should not be referred to as CT units
    Bushong, Stewart Carlyle
    Balter, Stephen
    Orton, Colin G.
    [J]. MEDICAL PHYSICS, 2011, 38 (01) : 1 - 4
  • [45] Patient-Specific Qa for Cyberknife Using a Portable Flat-Panel Imager
    Gersh, J.
    DuBose, R.
    Shay, K.
    Fulkerson, R.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3061 - 3061
  • [46] Technical Note: Skin thickness measurements using high-resolution flat-panel cone-beam dedicated breast CT
    Shi, Linxi
    Vedantham, Srinivasan
    Karellas, Andrew
    O'Connell, Avice M.
    [J]. MEDICAL PHYSICS, 2013, 40 (03)
  • [47] Relative dosimetry using active matrix flat-panel imager (AMFPI) technology
    El-Mohri, Y
    Antonuk, LE
    Yorkston, J
    Jee, KW
    Maolinbay, M
    Lam, KL
    Siewerdsen, JH
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1530 - 1541
  • [48] Image quality of flat panel cone-beam CT
    Rose, G
    Wiegert, J
    Schäfer, D
    Fiedler, K
    Conrads, N
    Timmer, J
    Rasche, V
    Noordhoek, N
    Klotz, E
    Koppe, R
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 677 - 683
  • [49] Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography
    El-Mohri, Youcef
    Antonuk, Larry E.
    Zhao, Qihua
    Wang, Yi
    Li, Yixin
    Du, Hong
    Sawant, Amit
    [J]. MEDICAL PHYSICS, 2007, 34 (01) : 315 - 327
  • [50] PERFORMANCE EVALUATION OF A HIGH-RESOLUTION, FLAT-PANEL, FLUOROSCOPIC AND RADIOGRAPHIC DIGITAL IMAGER
    ANTONUK, LE
    ELMOHRI, Y
    SIEWERDSEN, JH
    YORKSTON, J
    HUANG, W
    [J]. RADIOLOGY, 1995, 197 : 358 - 358