Percutaneous bone biopsy using a flat-panel cone beam computed tomography virtual navigation system

被引:4
|
作者
Liu, Juan-Fang [1 ]
Jiao, De-Chao [1 ]
Ren, Jian-Zhuang [1 ]
Zhang, Wen-Guang [1 ]
Han, Xin-Wei [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Intervent Radiol, Zhengzhou, Henan, Peoples R China
关键词
NEEDLE-BIOPSY; CT; GUIDANCE; LESIONS;
D O I
10.15537/smj.2018.5.21872
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To assess the clinical role of flat-panel cone beam CT (CBCT) in performing percutaneous needle biopsy (PNB) of bone lesions. Flat-panel cone beam CT systems have been used as a guidance tool for performing percutaneous biopsy. Real-time fluoroscopy and virtual navigation systems help simplify needle path planning and shorten procedure times. Methods: From March 2012 to March 2016, 80 patients with 80 bone lesions were retrospectively enrolled in the study in Zhengzhou city of China. Technical success, diagnostic accuracy, puncture performance, procedure time, complications, and effective radiation exposure were calculated. Results: All biopsies were technically successful (100%). Sufficient tissue for histopathological analysis was obtained in 75 of 80 cases. The sensitivity of PNB of bone lesions was 95.5%, the specificity was 83.3%, and accuracy was 93.7%. The mean scoring of puncture performance was 3.9 +/- 1.3. The mean total procedure time was 13.20 +/- 4.4 min, resulting in a mean exposure dose of 11.3 +/- 5.1 mSv. The complication rate was 8.7%. Conclusion: Percutaneous bone biopsy using CBCT is a safe and effective method that simplifies needle path planning and shortens procedure times.
引用
收藏
页码:519 / 523
页数:5
相关论文
共 50 条
  • [1] Planar cone-beam computed tomography with a flat-panel detector
    Kim, S. H.
    Kim, D. W.
    Youn, H.
    Kim, D.
    Kam, S.
    Jeon, H.
    Kim, H. K.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [2] Noise Characterization of a Clinical Flat-Panel Cone-Beam Computed Tomography (CBCT) System
    Vedantham, S.
    Gounis, M.
    van der Bom, M.
    Karellas, A.
    Wakhloo, A.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [3] Cone-beam computed tomography on a medical linear accelerator using a flat-panel imager
    Jaffray, DA
    Siewerdsen, JH
    Groh, B
    Drake, DG
    Wong, JW
    Martinez, AA
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 558 - 560
  • [4] Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    Jaffray, DA
    Siewerdsen, JH
    [J]. MEDICAL PHYSICS, 2000, 27 (06) : 1311 - 1323
  • [5] Cone-beam computed tomography with a flat-panel imager: Effects of image lag
    Siewerdsen, JH
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 1999, 26 (12) : 2635 - 2647
  • [6] Flat panel cone beam computed tomography of the sinuses
    Zoumalan, Richard A.
    Lebowitz, Richard A.
    Wang, Edwin
    Yung, Kathryn
    Babb, James S.
    Jacobs, Joseph B.
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2009, 140 (06) : 841 - 844
  • [7] Flat-panel cone-beam computed tomography for image-guided radiation therapy
    Jaffray, DA
    Siewerdsen, JH
    Wong, JW
    Martinez, AA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1337 - 1349
  • [8] View-dependent geometric calibration for offset flat-panel cone beam computed tomography systems
    Van-Giang Nguyen
    [J]. OPTICAL ENGINEERING, 2016, 55 (04)
  • [9] Aging of imaging properties of a CMOS flat-panel detector for dental cone-beam computed tomography
    Kim, D. W.
    Han, J. C.
    Yun, S.
    Kim, H. K.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [10] Optimal x-ray imaging geometry for flat-panel cone-beam computed tomography
    Siewerdsen, JH
    Jaffray, DA
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 106 - 107