Flat-panel cone-beam computed tomography for image-guided radiation therapy

被引:1063
|
作者
Jaffray, DA [1 ]
Siewerdsen, JH [1 ]
Wong, JW [1 ]
Martinez, AA [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
关键词
cone-beam computed tomography; linear accelerator; image guidance; flat-panel detectors;
D O I
10.1016/S0360-3016(02)02884-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Geometric uncertainties in the process of radiation planning and delivery constrain dose escalation and induce normal tissue complications. An imaging system has been developed to generate high-resolution, soft-tissue images of the patient at the time of treatment for the purpose of guiding therapy and reducing such uncertainties. The performance of the imaging system is evaluated and the application to image-guided radiation therapy is discussed. Methods and Materials: A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography (CT) has been integrated with a medical linear accelerator. Kilovoltage X-rays are generated by a conventional X-ray tube mounted on a retractable arm at 90degrees to the treatment source. A 41 X 41 cm(2) flat-panel X-ray detector is mounted opposite the kV tube. The entire imaging system operates under computer control, with a single application providing calibration, image acquisition, processing, and cone-beam CT reconstruction. Cone-beam CT imaging involves acquiring multiple kV radiographs as the gantry rotates through 360degrees of rotation. A filtered back-projection algorithm is employed to reconstruct the volumetric images. Geometric nonidealities in the rotation of the gantry system are measured and corrected during reconstruction. Qualitative evaluation of imaging performance is performed using an anthropomorphic head phantom and a coronal contrast phantom. The influence of geometric nonidealities is examined. Results: Images of the head phantom were acquired and illustrate the submillimeter spatial resolution that is achieved with the cone-beam approach. High-resolution sagittal and coronal views demonstrate nearly isotropic spatial resolution. Flex corrections on the order of 0.2 cm were required to compensate gravity-induced flex in the support arms of the source and detector, as well as slight axial movements of the entire gantry structure. Images reconstructed without flex correction suffered from loss of detail, misregistration, and streak artifacts. Reconstructions of the contrast phantom demonstrate the soft-tissue imaging capability of the system. A contrast of 47 Hounsfield units was easily detected in a 0.1-cm-thick reconstruction for an imaging exposure of 1.2 R (in-air, in absence of phantom). The comparison with a conventional CT scan of the phantom further demonstrates the spatial resolution advantages of the cone-beam CT approach. Conclusions: A kV cone-beam CT imaging system based on a large-area, flat-panel detector has been successfully adapted to a medical linear accelerator. The system is capable of producing images of soft tissue with excellent spatial resolution at acceptable imaging doses. Integration of this technology with the medical accelerator will result in an ideal platform for high-precision, image-guided radiation therapy. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1337 / 1349
页数:13
相关论文
共 50 条
  • [1] Commissioning experience with cone-beam computed tomography for image-guided radiation therapy
    Lehmann, Joerg
    Perks, Julian
    Semon, Sheldon
    Harse, Rick
    Purdy, James A.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (03): : 21 - 36
  • [2] Cone-beam computed tomography with a flat-panel imager: Effects of image lag
    Siewerdsen, JH
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 1999, 26 (12) : 2635 - 2647
  • [3] Planar cone-beam computed tomography with a flat-panel detector
    Kim, S. H.
    Kim, D. W.
    Youn, H.
    Kim, D.
    Kam, S.
    Jeon, H.
    Kim, H. K.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [4] Cone-beam CT with flat-panel detectors: Applications in diagnostic and image-guided procedures
    Siewerdsen, I
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2057 - 2058
  • [5] Flat-panel cone-beam CT: A novel imaging technology for image-guided procedures
    Siewerdsen, JH
    Jaffray, DA
    Edmundson, GK
    Sanders, WP
    Wong, J
    Martinez, AA
    [J]. MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 : 435 - 444
  • [6] Cone-beam CT with a flat-panel detector: From image science to image-guided surgery
    Siewerdsen, Jeffrey H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S241 - S250
  • [7] Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy
    Brunner, Stephen
    Nett, Brian E.
    Tolakanahalli, Ranjini
    Chen, Guang-Hong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04): : 1015 - 1030
  • [8] Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    Jaffray, DA
    Siewerdsen, JH
    [J]. MEDICAL PHYSICS, 2000, 27 (06) : 1311 - 1323
  • [9] Optimization of four-dimensional cone-beam computed tomography in image-guided radiation therapy of the lung
    Ahmad, Moiz
    Pan, Tinsu
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [10] Flat-panel cone-beam CT on a mobile isocentric C-arm for image-guided brachytherapy
    Jaffray, DA
    Siewerdsen, JH
    Edmundson, G
    Wong, J
    Martinez, A
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 209 - 217