Image Quality and Mean Glandular Dose in Mexican Mammography Services Measured with an Object-Insert/TL Mammography Kit

被引:1
|
作者
Lopez-Pineda, Eduardo [1 ]
Ruiz-Trejo, Cesar [1 ]
Brandan, Maria-Ester [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Fis, Cd Mx, Mexico
关键词
DOSIMETRY; PHANTOM;
D O I
10.1063/1.4954124
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Thirty mammography systems were evaluated using an Object-insert/TL kit (composed of an image quality and a dosimetric phantom) to assess image quality and mean glandular dose. All systems complied with the minimum score for object visibility in the image phantom, but most of the images showed artifacts. The average of the mean glandular dose was 1.7 +/- 0.7 mGy, and three systems delivered doses higher than the 3 mGy reference value. A weak correlation was found between image quality and dose, possibly reflecting the lack of quality control in the evaluated equipment.
引用
收藏
页数:5
相关论文
共 24 条
  • [1] A Mammography Phantom to Measure Mean Glandular Dose and Image Quality
    Lopez-Pineda, E.
    Ruiz-Trejo, C.
    Brandan, M. E.
    [J]. MEDICAL PHYSICS, 2014, 41 (06)
  • [2] Historical trends in image quality and mean glandular dose in digital mammography
    Mackenzie, Alistair
    Khan, Riyad
    Young, Kenneth C.
    [J]. 15TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI2020), 2020, 11513
  • [3] Image quality, threshold contrast and mean glandular dose in CR mammography
    Jakubiak, R. R.
    Gamba, H. R.
    Neves, E. B.
    Peixoto, J. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (18): : 6565 - 6583
  • [4] Mammography equipment performance, image quality and mean glandular dose in Malta
    Borg, M.
    Badr, I.
    Royle, G. J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 156 (02) : 168 - 183
  • [5] Average glandular dose and phantom image quality in mammography
    Oliveira, M.
    Noguelra, M. S.
    Guedes, E.
    Andrade, M. C.
    Peixoto, J. E.
    Joana, G. S.
    Castro, J. G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 574 - 577
  • [6] Clinical image quality assessment and mean glandular dose for full field digital mammography
    Nassar, Joyce
    Rizk, Chadia
    Fares, Georges
    Tohme, Carla
    Braidy, Chady
    Farah, Jad
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (01)
  • [7] Optimization of image quality and average glandular dose in CR mammography
    Satoh, Kimihiko
    Kuwabara, Takao
    Yasuda, Hiroaki
    Arakawa, Satoshi
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [8] Effect of filter on average glandular dose and image quality in digital mammography
    Songsaeng, C.
    Krisanachinda, A.
    Theerakul, K.
    [J]. 13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [9] ASSESSING IMAGE QUALITY AND ESTIMATING THE GLANDULAR AVERAGE DOSE IN SOME MAMMOGRAPHY LABS
    Mossang, D.
    Dadulescu, E.
    [J]. ROMANIAN REPORTS IN PHYSICS, 2011, 63 (01) : 95 - 106
  • [10] MEAN GLANDULAR DOSE IN SIX DIGITAL MAMMOGRAPHY SERVICES IN SANTIAGO, CHILE: PRELIMINARY REFERENCE LEVELS
    Leyton, Fernando
    Nogueira, Maria Do Socorro
    Dantas, Marcelino
    Paz Duran, Maria
    Ubeda, Carlos
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 115 - 120