ASSESSING IMAGE QUALITY AND ESTIMATING THE GLANDULAR AVERAGE DOSE IN SOME MAMMOGRAPHY LABS

被引:0
|
作者
Mossang, D.
Dadulescu, E.
机构
关键词
breast cancer; mammography; quality control; average glandular dose; IMPLEMENTATION; PROGRAM;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Mammography is the safest method of detecting breast cancer but, at the same time, the most exacting radiological examination which implies getting high quality images and a minimum dose per breast. The present study was carried out in six mammography laboratories, from which only one has partially implemented a programme of quality control. There were evaluated the phantom image, film contrast, background optical density (OD), density difference (DD), radiation beam quality, and the entrance surface air kerma was measured. The glandular average dose was also estimated. Compared to the reference lab, all the other five labs failed all the tests, obtaining unacceptable results both for the phantom image and for the contrast, for the OD and DD. The average glandular doses estimated for the standard breast varied between 1.4 and 7.7 mSv, being in four out of the six hospitals, statistically significant (p < 0.001), lower or higher than those currently accepted by international authorities (3mSv). Such simple quality control procedures will improve the chances of accurate diagnosis and reduce the probability of false negatives. This is particularly important for early detection and treatment of breast cancer which is the highest type of cancer among females.
引用
收藏
页码:95 / 106
页数:12
相关论文
共 50 条
  • [1] Average glandular dose and phantom image quality in mammography
    Oliveira, M.
    Noguelra, M. S.
    Guedes, E.
    Andrade, M. C.
    Peixoto, J. E.
    Joana, G. S.
    Castro, J. G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 574 - 577
  • [2] Optimization of image quality and average glandular dose in CR mammography
    Satoh, Kimihiko
    Kuwabara, Takao
    Yasuda, Hiroaki
    Arakawa, Satoshi
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [3] Effect of filter on average glandular dose and image quality in digital mammography
    Songsaeng, C.
    Krisanachinda, A.
    Theerakul, K.
    [J]. 13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [4] Evaluation of Image Quality and Average Glandular Dose Using the Resolution Testing Phantom in Mammography
    Chao, Y. T.
    Chen, C. Y.
    Dong, S. L.
    [J]. 1ST GLOBAL CONFERENCE ON BIOMEDICAL ENGINEERING & 9TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 47 : 144 - 146
  • [5] RADIATION QUALITY IN ASSESSING GLANDULAR DOSE IN FILM SCREEN MAMMOGRAPHY
    SERVOMAA, A
    TAPIOVAARA, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09): : 1247 - 1248
  • [6] Optimizing the anode-filter combination in the sense of image quality and average glandular dose in digital mammography
    Varjonen, Mari
    Stroemmer, Pekka
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [7] Optimizing the target-filter combination in digital mammography in the sense of image quality and average glandular dose
    Varjonen, Mari
    Strommer, Pekka
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 570 - 576
  • [8] Patient Specific Average Glandular Dose in Mammography
    Patel, V.
    Highnam, R.
    Tromans, C.
    Pizzutiello, R. J.
    Destounis, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] NORMALIZED AVERAGE GLANDULAR DOSE IN MAGNIFICATION MAMMOGRAPHY
    LIU, B
    GOODSITT, M
    CHAN, HP
    [J]. RADIOLOGY, 1995, 197 (01) : 27 - 32
  • [10] A Mammography Phantom to Measure Mean Glandular Dose and Image Quality
    Lopez-Pineda, E.
    Ruiz-Trejo, C.
    Brandan, M. E.
    [J]. MEDICAL PHYSICS, 2014, 41 (06)