Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging

被引:134
|
作者
Tong, SD
Cardinal, HN
McLoughlin, RF
Downey, DB
Fenster, A
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] London Hlth Sci Ctr, Dept Radiol, London, ON, Canada
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1998年 / 24卷 / 05期
基金
英国医学研究理事会;
关键词
three-dimensional ultrasound; sonography; imaging; prostate; volume; variability; reliability; planimetry; HWL method; transrectal ultrasound;
D O I
10.1016/S0301-5629(98)00039-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We describe the results of a study to evaluate the intra- and inter-observer variability and reliability of prostate volume measurements made from transrectal ultrasound (TRUS) images, using either the (optimal) height-width-length (HWL) method (V = pi/6 HWL) with two-dimensional (2D) TRUS images (obtained as cross-sections of three-dimensional [3D] TRUS images) or manual planimetry of 3D TRUS images (the 3D US method). In this study, eight observers measured 15 prostate images, twice via each method, and an analysis of variance (ANOVA) was performed. This analysis shows that, with the 3D US method, intra-observer prostate volume estimates have 5.1% variability and 99% reliability, and inter-observer estimates have 11.4% variability and 96% reliability, With the HWL method, intra-observer estimates have 15.5% variability and 93 % reliability, and inter-observer estimates have 21.9% variability and 87% reliability. Thus, in vivo prostate volume estimates from manual planimetry of 3D TRUS images have much lower variability and higher reliability than HWL estimates from 2D TRUS images. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:673 / 681
页数:9
相关论文
共 50 条
  • [41] Intra- and inter-operator reliability of three-dimensional preoperative planning in total knee arthroplasty
    Cosendey, Killian
    Moerenhout, Kevin
    Stanovici, Julien
    Jolles, Brigitte M.
    Favre, Julien
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (08) : 3625 - 3630
  • [42] Reliability and validity of two methods of three-dimensional cervical volume measurement
    Farrell, T
    Cairns, M
    Leslie, J
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) : 49 - 52
  • [43] Reliability and validity of tissue volume measurement by three-dimensional ultrasound: an experimental model
    Martins, W. P.
    Ferriani, R. A.
    Barra, D. A.
    Dos Reis, R. M.
    Bortolieiro, M. A. V.
    Nastri, C. O.
    Mauad Filho, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (02) : 210 - 214
  • [44] INTRA- AND INTER-OBSERVER VARIABILITY OF INTERNAL TARGET VOLUME DELINEATION AND VOLUME CHANGES OF LUNG TUMOURS ON REPEATED CT SCANS
    Petoukhova, A.
    Steyn, T.
    Kalidien, Y.
    Kouwenhoven, E.
    de Haan, P.
    Wiggenraad, R.
    Verbeek-de Kanter, A.
    van de Vaart, P.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S353 - S354
  • [45] Assessment of Intra- and Inter-observer Measurement Variability in a Radiographic Metacarpophalangeal Joint Osteophytosis Scoring System for the Horse
    Lacitignola, Luca
    Imperante, Annarita
    Staffieri, Francesco
    De Siena, Rocco
    De Luca, Pasquale
    Muci, Arianna
    Crovace, Antonio
    VETERINARY SCIENCES, 2020, 7 (02)
  • [46] Intra- and inter-observer variability in measurement of target lesions: implication on response evaluation according to RECIST 1.1
    Muenzel, Daniela
    Engels, Heinz-Peter
    Bruegel, Melanie
    Kehl, Victoria
    Rummeny, Ernst J.
    Metz, Stephan
    RADIOLOGY AND ONCOLOGY, 2012, 46 (01) : 8 - 18
  • [47] Prenatal diagnosis of duplicated gallbladder: two-dimensional and three-dimensional ultrasound imaging and reconstruction
    Pacheco, G. H. A. S.
    Castro, P. T.
    Tonni, G.
    Werner, H.
    Araujo, E.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2025,
  • [48] A comparison of standard two-dimensional ultrasound to three-dimensional volume sonography for routine second-trimester fetal imaging
    Roy-Lacroix, M. E.
    Moretti, F.
    Ferraro, Z. M.
    Brosseau, L.
    Clancy, J.
    Fung-Kee-Fung, K.
    JOURNAL OF PERINATOLOGY, 2017, 37 (04) : 380 - 386
  • [49] A comparison of standard two-dimensional ultrasound to three-dimensional volume sonography for routine second-trimester fetal imaging
    M E Roy-Lacroix
    F Moretti
    Z M Ferraro
    L Brosseau
    J Clancy
    K Fung-Kee-Fung
    Journal of Perinatology, 2017, 37 : 380 - 386
  • [50] Three-dimensional transistor arrays for intra- and inter-cellular recording
    Gu, Yue
    Wang, Chunfeng
    Kim, Namheon
    Zhang, Jingxin
    Wang, Tsui Min
    Stowe, Jennifer
    Nasiri, Rohollah
    Li, Jinfeng
    Zhang, Daibo
    Yang, Albert
    Hsu, Leo Huan-Hsuan
    Dai, Xiaochuan
    Mu, Jing
    Liu, Zheyuan
    Lin, Muyang
    Li, Weixin
    Wang, Chonghe
    Gong, Hua
    Chen, Yimu
    Lei, Yusheng
    Hu, Hongjie
    Li, Yang
    Zhang, Lin
    Huang, Zhenlong
    Zhang, Xingcai
    Ahadian, Samad
    Banik, Pooja
    Zhang, Liangfang
    Jiang, Xiaocheng
    Burke, Peter J.
    Khademhosseini, Ali
    McCulloch, Andrew D.
    Xu, Sheng
    NATURE NANOTECHNOLOGY, 2022, 17 (03) : 292 - +