Intra- and inter-operator reliability of three-dimensional preoperative planning in total knee arthroplasty

被引:0
|
作者
Cosendey, Killian [1 ,2 ]
Moerenhout, Kevin [1 ,2 ]
Stanovici, Julien [1 ,2 ]
Jolles, Brigitte M. [1 ,2 ,3 ]
Favre, Julien [1 ,2 ,4 ,5 ]
机构
[1] Lausanne Univ Hosp, Dept Musculoskeletal Med DAL, Ave Pierre Decker 4, CH-1005 Lausanne, Switzerland
[2] Univ Lausanne CHUV UNIL, Ave Pierre Decker 4, CH-1005 Lausanne, Switzerland
[3] Ecole Polytech Fed Lausanne EPFL, Inst Elect & Micro Engn, Lausanne, Switzerland
[4] Sense Innovat & Res Ctr, Lausanne, Switzerland
[5] Sense Innovat & Res Ctr, Sion, Switzerland
关键词
Total knee arthroplasty; Preoperative planning; Reliability; Implant size selection; Implant placement; TIBIAL COMPONENT; RISK; OVERHANG; PAIN;
D O I
10.1007/s00402-024-05438-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo characterize the intra- and inter-operator reliability of a CT-based 3D preoperative planning software.Materials and methodsThis study analyzed 30 CT scans of de-identified knees with osteoarthritis. For each scan, a case planner segmented the bones and pre-planned the TKA. Three orthopedic surgeons then reviewed each pre-planning three times at least one week apart, in a blinded manner. During the reviews, the surgeons modified the pre-plannings until they felt the plannings matched the objectives defined collegially at the beginning of the study. Reliability was assessed using the Intraclass Correlation Coefficient (ICC) and the Standard Error of Measurement (SEM).ResultsThe intra- and inter-operator reliabilities for implant size selection were almost perfect (ICC between 0.97 and 0.99). Implants of same sizes were selected in 67.1-90.0% of cases. For implant placements, almost perfect intra- and inter-operator reliability was observed in all degrees-of-freedom (ICC between 0.81 and 1.00), except in flexion-extension for the femur (intra-operator ICC between: 0.76 and 0.99; inter-operator ICC of 0.61) and the tibia (intra-operator ICC between 0.12 and 1.00; inter-operator ICC of 0.03). All implant placements SEM were below 1.3 mm or 1.7 degrees.ConclusionsThis study showed high intra- and inter-operator reliability for implant size selection and, in most of the degrees-of-freedom, also for implant placements. Further research is needed to evaluate the benefit of developing more precise means of describing the objectives of the surgical planning as well as to evaluate the possibility and relevance of adding features in the planning software to assist the operators.
引用
下载
收藏
页码:3625 / 3630
页数:6
相关论文
共 50 条
  • [1] Preoperative planning of total knee arthroplasty: reliability of axial alignment using a three-dimensional planning approach
    Tiefenboeck, Stefan
    Sesselmann, Stefan
    Taylor, Dominic
    Forst, Raimund
    Seehaus, Frank
    ACTA RADIOLOGICA, 2022, 63 (08) : 1051 - 1061
  • [2] Intra- and inter-operator reliability assessment of a novel extramedullary accelerometer-based smart cutting guide for total knee arthroplasty: an in vivo study
    Giulio Maria Marcheggiani Muccioli
    Domenico Alesi
    Arcangelo Russo
    Mirco Lo Presti
    Iacopo Sassoli
    Matteo La Verde
    Stefano Zaffagnini
    International Orthopaedics, 2023, 47 : 83 - 87
  • [3] Intra- and inter-operator reliability assessment of a novel extramedullary accelerometer-based smart cutting guide for total knee arthroplasty: an in vivo study
    Muccioli, Giulio Maria Marcheggiani
    Alesi, Domenico
    Russo, Arcangelo
    Lo Presti, Mirco
    Sassoli, Iacopo
    La Verde, Matteo
    Zaffagnini, Stefano
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (01) : 83 - 87
  • [4] Intra- and interobserver reliability and agreement in three-dimensional computed tomography measurements of component positions after total knee arthroplasty
    Yoshino, Kensuke
    Hagiwara, Shigeo
    Nakamura, Junichi
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Ohtori, Seiji
    KNEE, 2019, 26 (05): : 1102 - 1110
  • [5] Intra- and inter-observer reliability of implant positioning evaluation on a CT-based three-dimensional postoperative matching system for total knee arthroplasty
    Watanabe, Shotaro
    Akagi, Ryuichiro
    Shiko, Yuki
    Ono, Yoshimasa
    Kawasaki, Yohei
    Ohdera, Toshihiro
    Ohtori, Seiji
    Sasho, Takahisa
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [6] Individualizing a Total Knee Arthroplasty with Three-Dimensional Planning
    Dossett, Harold Gene
    Deckey, David G.
    Clarke, Henry D.
    Spangehl, Mark J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS, 2024, 8 (03):
  • [7] Interobserver and Intraobserver Reliability of Three-Dimensional Preoperative Planning Software in Total Hip Arthroplasty
    Wako, Yasushi
    Nakamura, Junichi
    Miura, Michiaki
    Kawarai, Yuya
    Sugano, Masahiko
    Nawata, Kento
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 601 - 607
  • [8] Interobserver and Intraobserver Reliability of Computed Tomography-Based Three-Dimensional Preoperative Planning for Primary Total Knee Arthroplasty
    Miura, Michiaki
    Hagiwara, Shigeo
    Nakamura, Junichi
    Wako, Yasushi
    Kawarai, Yuya
    Ohtori, Seiji
    JOURNAL OF ARTHROPLASTY, 2018, 33 (05): : 1572 - 1578
  • [9] Intra- and inter-operator variability of refractometric total proteins measurement of canine plasma
    Venier, F.
    Jamont, W.
    McLennan, K.
    Rosa, C.
    JOURNAL OF THE SOUTH AFRICAN VETERINARY ASSOCIATION, 2022, 93 (02) : 173 - 175
  • [10] Intra- and inter‐observer reliability of implant positioning evaluation on a CT-based three‐dimensional postoperative matching system for total knee arthroplasty
    Shotaro Watanabe
    Ryuichiro Akagi
    Yuki Shiko
    Yoshimasa Ono
    Yohei Kawasaki
    Toshihiro Ohdera
    Seiji Ohtori
    Takahisa Sasho
    BMC Musculoskeletal Disorders, 22