Intra- and inter-operator reliability of three-dimensional preoperative planning in total knee arthroplasty

被引:0
|
作者
Cosendey, Killian [1 ,2 ]
Moerenhout, Kevin [1 ,2 ]
Stanovici, Julien [1 ,2 ]
Jolles, Brigitte M. [1 ,2 ,3 ]
Favre, Julien [1 ,2 ,4 ,5 ]
机构
[1] Lausanne Univ Hosp, Dept Musculoskeletal Med DAL, Ave Pierre Decker 4, CH-1005 Lausanne, Switzerland
[2] Univ Lausanne CHUV UNIL, Ave Pierre Decker 4, CH-1005 Lausanne, Switzerland
[3] Ecole Polytech Fed Lausanne EPFL, Inst Elect & Micro Engn, Lausanne, Switzerland
[4] Sense Innovat & Res Ctr, Lausanne, Switzerland
[5] Sense Innovat & Res Ctr, Sion, Switzerland
关键词
Total knee arthroplasty; Preoperative planning; Reliability; Implant size selection; Implant placement; TIBIAL COMPONENT; RISK; OVERHANG; PAIN;
D O I
10.1007/s00402-024-05438-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo characterize the intra- and inter-operator reliability of a CT-based 3D preoperative planning software.Materials and methodsThis study analyzed 30 CT scans of de-identified knees with osteoarthritis. For each scan, a case planner segmented the bones and pre-planned the TKA. Three orthopedic surgeons then reviewed each pre-planning three times at least one week apart, in a blinded manner. During the reviews, the surgeons modified the pre-plannings until they felt the plannings matched the objectives defined collegially at the beginning of the study. Reliability was assessed using the Intraclass Correlation Coefficient (ICC) and the Standard Error of Measurement (SEM).ResultsThe intra- and inter-operator reliabilities for implant size selection were almost perfect (ICC between 0.97 and 0.99). Implants of same sizes were selected in 67.1-90.0% of cases. For implant placements, almost perfect intra- and inter-operator reliability was observed in all degrees-of-freedom (ICC between 0.81 and 1.00), except in flexion-extension for the femur (intra-operator ICC between: 0.76 and 0.99; inter-operator ICC of 0.61) and the tibia (intra-operator ICC between 0.12 and 1.00; inter-operator ICC of 0.03). All implant placements SEM were below 1.3 mm or 1.7 degrees.ConclusionsThis study showed high intra- and inter-operator reliability for implant size selection and, in most of the degrees-of-freedom, also for implant placements. Further research is needed to evaluate the benefit of developing more precise means of describing the objectives of the surgical planning as well as to evaluate the possibility and relevance of adding features in the planning software to assist the operators.
引用
下载
收藏
页码:3625 / 3630
页数:6
相关论文
共 50 条
  • [21] Liger: Interleaving Intra- and Inter-Operator Parallelism for Distributed Large Model Inference
    Du, Jiangsu
    Wei, Jinhui
    Jiang, Jiazhi
    Cheng, Shenggan
    Huang, Dan
    Chen, Zhiguang
    Lu, Yutong
    PROCEEDINGS OF THE 29TH ACM SIGPLAN ANNUAL SYMPOSIUM ON PRINCIPLES AND PRACTICE OF PARALLEL PROGRAMMING, PPOPP 2024, 2024, : 42 - 54
  • [22] High intra- and inter-observer reliability of planning implant size in MRI-based patient-specific instrumentation for total knee arthroplasty
    Schoenmakers, Daphne A. L.
    Theeuwen, Dieuwertje M. J.
    Schotanus, Martijn G. M.
    Jansen, Edwin J. P.
    van Haaren, Emil H.
    Hendrickx, Roel P. M.
    Kort, Nanne P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (02) : 573 - 578
  • [23] High intra- and inter-observer reliability of planning implant size in MRI-based patient-specific instrumentation for total knee arthroplasty
    Daphne A. L. Schoenmakers
    Dieuwertje M. J. Theeuwen
    Martijn G. M. Schotanus
    Edwin J. P. Jansen
    Emil H. van Haaren
    Roel P. M. Hendrickx
    Nanne P. Kort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2021, 29 : 573 - 578
  • [24] Intra- and Inter-Operator Variability in HR-pQCT Scan Positioning.
    Bonaretti, Serena
    Holets, Margaret
    Derrico, Nicholas P.
    Nishiyama, Kyle
    Liu, Danmei
    Boutroy, Stephanie
    Chapurlat, Roland
    McKay, Heather
    Shane, Elizabeth
    Bouxsein, Mary
    Lang, Thomas
    Khosla, Sundeep
    Burghardt, Andrew
    JOURNAL OF BONE AND MINERAL RESEARCH, 2014, 29 : S437 - S437
  • [25] Performance Characteristics, Intra- & Inter-Operator Agreement of Transient Elastography in Pediatric NAFLD
    Mandelia, Chetan
    Worley, Sarah
    Kabbany, Mohammad Nasser
    Selvakumar, Praveen Kumar Conjeevaram
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2022, 74 (01): : E19 - E20
  • [26] The occlusal plane in the facial context: inter-operator repeatability of a new three-dimensional method
    Riccardo Rosati
    Alberto Rossetti
    Marcio De Menezes
    Virgilio F Ferrario
    Chiarella Sforza
    International Journal of Oral Science, 2012, 4 : 34 - 37
  • [27] The Reliability of Preoperative Total Knee Arthroplasty Planning -a Comparison of Two Calibration Markers
    Grevenstein, David
    Oppermann, Johannes
    Spies, Christian Karl
    Paul, Christian
    Eysel, Peer
    Ott, Nadine
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2024, 162 (02): : 179 - 184
  • [28] The occlusal plane in the facial context: inter-operator repeatability of a new three-dimensional method
    Rosati, Riccardo
    Rossetti, Alberto
    De Menezes, Marcio
    Ferrario, Virgilio F.
    Sforza, Chiarella
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2012, 4 (01) : 34 - 37
  • [29] The occlusal plane in the facial context:inter-operator repeatability of a new three-dimensional method
    Riccardo Rosati
    Alberto Rossetti
    Marcio De Menezes
    Virgilio F Ferrario
    Chiarella Sforza
    International Journal of Oral Science, 2012, 4 (01) : 34 - 37
  • [30] Inter-operator Variability in Defining Uterine Position Using Three-dimensional Ultrasound Imaging
    Baker, Mariwan
    Jensen, Jorgen Arendt
    Behrens, Claus F.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 840 - 843