Intra- and inter-operator reliability of three-dimensional preoperative planning in total knee arthroplasty

被引:0
|
作者
Cosendey, Killian [1 ,2 ]
Moerenhout, Kevin [1 ,2 ]
Stanovici, Julien [1 ,2 ]
Jolles, Brigitte M. [1 ,2 ,3 ]
Favre, Julien [1 ,2 ,4 ,5 ]
机构
[1] Lausanne Univ Hosp, Dept Musculoskeletal Med DAL, Ave Pierre Decker 4, CH-1005 Lausanne, Switzerland
[2] Univ Lausanne CHUV UNIL, Ave Pierre Decker 4, CH-1005 Lausanne, Switzerland
[3] Ecole Polytech Fed Lausanne EPFL, Inst Elect & Micro Engn, Lausanne, Switzerland
[4] Sense Innovat & Res Ctr, Lausanne, Switzerland
[5] Sense Innovat & Res Ctr, Sion, Switzerland
关键词
Total knee arthroplasty; Preoperative planning; Reliability; Implant size selection; Implant placement; TIBIAL COMPONENT; RISK; OVERHANG; PAIN;
D O I
10.1007/s00402-024-05438-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo characterize the intra- and inter-operator reliability of a CT-based 3D preoperative planning software.Materials and methodsThis study analyzed 30 CT scans of de-identified knees with osteoarthritis. For each scan, a case planner segmented the bones and pre-planned the TKA. Three orthopedic surgeons then reviewed each pre-planning three times at least one week apart, in a blinded manner. During the reviews, the surgeons modified the pre-plannings until they felt the plannings matched the objectives defined collegially at the beginning of the study. Reliability was assessed using the Intraclass Correlation Coefficient (ICC) and the Standard Error of Measurement (SEM).ResultsThe intra- and inter-operator reliabilities for implant size selection were almost perfect (ICC between 0.97 and 0.99). Implants of same sizes were selected in 67.1-90.0% of cases. For implant placements, almost perfect intra- and inter-operator reliability was observed in all degrees-of-freedom (ICC between 0.81 and 1.00), except in flexion-extension for the femur (intra-operator ICC between: 0.76 and 0.99; inter-operator ICC of 0.61) and the tibia (intra-operator ICC between 0.12 and 1.00; inter-operator ICC of 0.03). All implant placements SEM were below 1.3 mm or 1.7 degrees.ConclusionsThis study showed high intra- and inter-operator reliability for implant size selection and, in most of the degrees-of-freedom, also for implant placements. Further research is needed to evaluate the benefit of developing more precise means of describing the objectives of the surgical planning as well as to evaluate the possibility and relevance of adding features in the planning software to assist the operators.
引用
下载
收藏
页码:3625 / 3630
页数:6
相关论文
共 50 条
  • [31] Preoperative Planning in Primary Total Knee Arthroplasty
    Tanzer, Michael
    Makhdom, Asim M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (04) : 220 - 230
  • [32] The occlusal plane in the facial context:inter-operator repeatability of a new three-dimensional method
    Riccardo Rosati
    Alberto Rossetti
    Marcio De Menezes
    Virgilio F Ferrario
    Chiarella Sforza
    International Journal of Oral Science, 2012, (01) : 34 - 37
  • [33] Preoperative planning for revision total knee arthroplasty
    Gustke, KA
    JOURNAL OF ARTHROPLASTY, 2005, 20 (04): : 37 - 40
  • [34] Three-Dimensional Preoperative Planning Software for Hip Resurfacing Arthroplasty
    Alagha, M. Abdulhadi
    Logishetty, Kartik
    O'Hanlon, Ciaran
    Liddle, Alexander D.
    Cobb, Justin
    BIOENGINEERING-BASEL, 2023, 10 (08):
  • [35] Three-dimensional transistor arrays for intra- and inter-cellular recording
    Gu, Yue
    Wang, Chunfeng
    Kim, Namheon
    Zhang, Jingxin
    Wang, Tsui Min
    Stowe, Jennifer
    Nasiri, Rohollah
    Li, Jinfeng
    Zhang, Daibo
    Yang, Albert
    Hsu, Leo Huan-Hsuan
    Dai, Xiaochuan
    Mu, Jing
    Liu, Zheyuan
    Lin, Muyang
    Li, Weixin
    Wang, Chonghe
    Gong, Hua
    Chen, Yimu
    Lei, Yusheng
    Hu, Hongjie
    Li, Yang
    Zhang, Lin
    Huang, Zhenlong
    Zhang, Xingcai
    Ahadian, Samad
    Banik, Pooja
    Zhang, Liangfang
    Jiang, Xiaocheng
    Burke, Peter J.
    Khademhosseini, Ali
    McCulloch, Andrew D.
    Xu, Sheng
    NATURE NANOTECHNOLOGY, 2022, 17 (03) : 292 - +
  • [36] Accuracy of computed tomography-based three-dimensional preoperative planning for total wrist arthroplasty
    Matsuo, Tomoki
    Iwamoto, Takuji
    Suzuki, Taku
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (05) : 476 - 478
  • [37] The Influence of Three-Dimensional Computed Tomography Images of the Shoulder in Preoperative Planning for Total Shoulder Arthroplasty
    Scalise, Jason J.
    Codsi, Michael J.
    Bryan, Jason
    Brems, John J.
    Iannotti, Joseph P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (11): : 2438 - 2445
  • [38] Comparisons of Preoperative Three-Dimensional Planning and Surgical Reconstruction in Primary Cementless Total Hip Arthroplasty
    Hassani, Hassen
    Cherix, Stephane
    Ek, Eugene T.
    Ruediger, Hannes A.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (06): : 1273 - 1277
  • [39] Three-dimensional transistor arrays for intra- and inter-cellular recording
    Yue Gu
    Chunfeng Wang
    Namheon Kim
    Jingxin Zhang
    Tsui Min Wang
    Jennifer Stowe
    Rohollah Nasiri
    Jinfeng Li
    Daibo Zhang
    Albert Yang
    Leo Huan-Hsuan Hsu
    Xiaochuan Dai
    Jing Mu
    Zheyuan Liu
    Muyang Lin
    Weixin Li
    Chonghe Wang
    Hua Gong
    Yimu Chen
    Yusheng Lei
    Hongjie Hu
    Yang Li
    Lin Zhang
    Zhenlong Huang
    Xingcai Zhang
    Samad Ahadian
    Pooja Banik
    Liangfang Zhang
    Xiaocheng Jiang
    Peter J. Burke
    Ali Khademhosseini
    Andrew D. McCulloch
    Sheng Xu
    Nature Nanotechnology, 2022, 17 : 292 - 300
  • [40] Intra-operator and inter-operator reliability of surface electromyography in the clinical evaluation of back muscles
    Danneels, LA
    Cagnie, BJ
    Cools, AM
    Vanderstraeten, GG
    Cambier, DC
    Witvrouw, EE
    De Cuyper, HJ
    MANUAL THERAPY, 2001, 6 (03) : 145 - 153