Intra- and inter-operator reliability of three-dimensional preoperative planning in total knee arthroplasty

被引:0
|
作者
Cosendey, Killian [1 ,2 ]
Moerenhout, Kevin [1 ,2 ]
Stanovici, Julien [1 ,2 ]
Jolles, Brigitte M. [1 ,2 ,3 ]
Favre, Julien [1 ,2 ,4 ,5 ]
机构
[1] Lausanne Univ Hosp, Dept Musculoskeletal Med DAL, Ave Pierre Decker 4, CH-1005 Lausanne, Switzerland
[2] Univ Lausanne CHUV UNIL, Ave Pierre Decker 4, CH-1005 Lausanne, Switzerland
[3] Ecole Polytech Fed Lausanne EPFL, Inst Elect & Micro Engn, Lausanne, Switzerland
[4] Sense Innovat & Res Ctr, Lausanne, Switzerland
[5] Sense Innovat & Res Ctr, Sion, Switzerland
关键词
Total knee arthroplasty; Preoperative planning; Reliability; Implant size selection; Implant placement; TIBIAL COMPONENT; RISK; OVERHANG; PAIN;
D O I
10.1007/s00402-024-05438-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo characterize the intra- and inter-operator reliability of a CT-based 3D preoperative planning software.Materials and methodsThis study analyzed 30 CT scans of de-identified knees with osteoarthritis. For each scan, a case planner segmented the bones and pre-planned the TKA. Three orthopedic surgeons then reviewed each pre-planning three times at least one week apart, in a blinded manner. During the reviews, the surgeons modified the pre-plannings until they felt the plannings matched the objectives defined collegially at the beginning of the study. Reliability was assessed using the Intraclass Correlation Coefficient (ICC) and the Standard Error of Measurement (SEM).ResultsThe intra- and inter-operator reliabilities for implant size selection were almost perfect (ICC between 0.97 and 0.99). Implants of same sizes were selected in 67.1-90.0% of cases. For implant placements, almost perfect intra- and inter-operator reliability was observed in all degrees-of-freedom (ICC between 0.81 and 1.00), except in flexion-extension for the femur (intra-operator ICC between: 0.76 and 0.99; inter-operator ICC of 0.61) and the tibia (intra-operator ICC between 0.12 and 1.00; inter-operator ICC of 0.03). All implant placements SEM were below 1.3 mm or 1.7 degrees.ConclusionsThis study showed high intra- and inter-operator reliability for implant size selection and, in most of the degrees-of-freedom, also for implant placements. Further research is needed to evaluate the benefit of developing more precise means of describing the objectives of the surgical planning as well as to evaluate the possibility and relevance of adding features in the planning software to assist the operators.
引用
下载
收藏
页码:3625 / 3630
页数:6
相关论文
共 50 条
  • [41] Intra- and inter-operator variation in TV image analysis of nuclei in oral smears.
    Rawashdeh, M
    Potts, AJ
    Cowpe, JG
    Walker, R
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1192 - 1192
  • [42] Intra- and inter-rater reliability of a three-dimensional classification system for intertrochanteric fracture using computed tomography
    Wada, Keizo
    Mikami, Hiroshi
    Toki, Shunichi
    Amari, Rui
    Takai, Michihiro
    Sairyo, Koichi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (11): : 2682 - 2685
  • [43] The value of three-dimensional computerised planning of total hip arthroplasty
    Sariali, Elhadi
    Mauprivez, Raphael
    Catonne, Yves
    SWISS MEDICAL WEEKLY, 2011, 141 : 6S - 6S
  • [44] Intra- and inter-operator reliability of measuring compressive stiffness of the patellar tendon in volleyball players using a handheld digital palpation device
    van Dam, Lotte
    Terink, Rieneke
    van den Akker-scheek, Inge
    Zwerver, Johannes
    PLOS ONE, 2024, 19 (06):
  • [45] Evaluation of the reproducibility of preoperative three-dimensional computed tomography planning for posterolateral approach total hip arthroplasty
    Kaneoka, Takehiro
    Imagama, Takashi
    Okazaki, Tomoya
    Matsuki, Yuta
    Kawakami, Takehiro
    Yamazaki, Kazuhiro
    Sakai, Takashi
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (02) : 146 - 153
  • [46] Preoperative planning to prevent instability in total knee arthroplasty
    Bobbins, GM
    Masri, BA
    Garbuz, DS
    Duncan, CP
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (04) : 611 - +
  • [47] Accuracy of digital preoperative planning for total knee arthroplasty
    Vanin, N.
    Kenaway, M.
    Panzica, M.
    Jagodzinski, M.
    Meller, R.
    Krettek, C.
    Hankemeier, S.
    TECHNOLOGY AND HEALTH CARE, 2010, 18 (4-5) : 335 - 340
  • [48] Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging
    Tong, SD
    Cardinal, HN
    McLoughlin, RF
    Downey, DB
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (05): : 673 - 681
  • [49] Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging
    Imaging Research Laboratories, J. P. Robarts Research Institute, London, Ont., Canada
    不详
    不详
    不详
    Ultrasound Med. Biol., 5 (673-681):
  • [50] Preoperative three-dimensional computer planning for reverse total shoulder arthroplasty and bone grafting for severe glenoid deformity
    Tashjian, Robert Z.
    Beck, Lindsay
    Stertz, Irene
    Chalmers, Peter N.
    SHOULDER & ELBOW, 2021, 13 (05) : 492 - 501