Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging

被引:134
|
作者
Tong, SD
Cardinal, HN
McLoughlin, RF
Downey, DB
Fenster, A
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] London Hlth Sci Ctr, Dept Radiol, London, ON, Canada
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1998年 / 24卷 / 05期
基金
英国医学研究理事会;
关键词
three-dimensional ultrasound; sonography; imaging; prostate; volume; variability; reliability; planimetry; HWL method; transrectal ultrasound;
D O I
10.1016/S0301-5629(98)00039-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We describe the results of a study to evaluate the intra- and inter-observer variability and reliability of prostate volume measurements made from transrectal ultrasound (TRUS) images, using either the (optimal) height-width-length (HWL) method (V = pi/6 HWL) with two-dimensional (2D) TRUS images (obtained as cross-sections of three-dimensional [3D] TRUS images) or manual planimetry of 3D TRUS images (the 3D US method). In this study, eight observers measured 15 prostate images, twice via each method, and an analysis of variance (ANOVA) was performed. This analysis shows that, with the 3D US method, intra-observer prostate volume estimates have 5.1% variability and 99% reliability, and inter-observer estimates have 11.4% variability and 96% reliability, With the HWL method, intra-observer estimates have 15.5% variability and 93 % reliability, and inter-observer estimates have 21.9% variability and 87% reliability. Thus, in vivo prostate volume estimates from manual planimetry of 3D TRUS images have much lower variability and higher reliability than HWL estimates from 2D TRUS images. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:673 / 681
页数:9
相关论文
共 50 条
  • [21] Three-dimensional ultrasound imaging of the prostate
    Tong, SD
    Cardinal, HN
    Downey, DB
    Fenster, A
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 113 - 123
  • [22] Three-dimensional ultrasound imaging of the prostate
    Fenster, A
    Downey, DB
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 2 - 11
  • [23] Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning
    Fiorino, C
    Reni, M
    Bolognesi, A
    Cattaneo, GM
    Calandrino, R
    RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) : 285 - 292
  • [24] BLADDER VOLUME DETERMINATION: TWO-DIMENSIONAL VERSUS THREE-DIMENSIONAL TRANSVAGINAL ULTRASOUND
    Liang, Ching-Chung
    Wei, Tien-Yung
    Chang, Shuenn-Dhy
    Hsieh, Ching-Chang
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2009, 48 (03): : 258 - 261
  • [25] Semiautomatic three-dimensional segmentation of the prostate using two-dimensional ultrasound images
    Wang, YQ
    Cardinal, HN
    Downey, DB
    Fenster, A
    MEDICAL PHYSICS, 2003, 30 (05) : 887 - 897
  • [26] NORMAL VALUES AND INTER-OBSERVER VARIABILITY FOR TWO-DIMENSIONAL ECHOCARDIOGRAPHIC MEASUREMENTS OF THE LEFT-VENTRICLE
    MELTZER, RS
    BASTIAANS, OL
    MCGHIE, J
    ROELANDT, J
    CLINICAL RESEARCH, 1980, 28 (03): : A616 - A616
  • [27] Measurement of Three-Dimensional Back Shape of Normal Adults Using a Novel Three-Dimensional Imaging Mobile Surface Topography System (MSTS): An Intra- and Inter-Rater Reliability Study
    Kandasamy, Gok
    Bettany-Saltikov, Josette
    Van Schaik, Paul
    HEALTHCARE, 2023, 11 (23)
  • [28] Evaluation of Intra- and Inter-observer Measurement Variability of a Radiographic Stifle Osteoarthritis Scoring System in Dogs
    Wessely, Marlis
    Bruehschwein, Andreas
    Schnabl-Feichter, Eva
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2017, 30 (06) : 377 - 384
  • [29] Accuracy of three-dimensional transvaginal ultrasound in uterus volume measurements;: Comparison with two-dimensional ultrasound
    Yaman, C
    Jesacher, K
    Pölz, W
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (12): : 1681 - 1684
  • [30] A comparison of three-dimensional ultrasound, two-dimensional ultrasound and dissections for determination of lesion volume in tendons
    Ferrari, M
    Weller, R
    Pfau, T
    Payne, RC
    Wilson, AM
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (06): : 797 - 804