Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging

被引:134
|
作者
Tong, SD
Cardinal, HN
McLoughlin, RF
Downey, DB
Fenster, A
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] London Hlth Sci Ctr, Dept Radiol, London, ON, Canada
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1998年 / 24卷 / 05期
基金
英国医学研究理事会;
关键词
three-dimensional ultrasound; sonography; imaging; prostate; volume; variability; reliability; planimetry; HWL method; transrectal ultrasound;
D O I
10.1016/S0301-5629(98)00039-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We describe the results of a study to evaluate the intra- and inter-observer variability and reliability of prostate volume measurements made from transrectal ultrasound (TRUS) images, using either the (optimal) height-width-length (HWL) method (V = pi/6 HWL) with two-dimensional (2D) TRUS images (obtained as cross-sections of three-dimensional [3D] TRUS images) or manual planimetry of 3D TRUS images (the 3D US method). In this study, eight observers measured 15 prostate images, twice via each method, and an analysis of variance (ANOVA) was performed. This analysis shows that, with the 3D US method, intra-observer prostate volume estimates have 5.1% variability and 99% reliability, and inter-observer estimates have 11.4% variability and 96% reliability, With the HWL method, intra-observer estimates have 15.5% variability and 93 % reliability, and inter-observer estimates have 21.9% variability and 87% reliability. Thus, in vivo prostate volume estimates from manual planimetry of 3D TRUS images have much lower variability and higher reliability than HWL estimates from 2D TRUS images. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:673 / 681
页数:9
相关论文
共 50 条
  • [31] Fetal biometry and estimated fetal weight in the second trimester: A comparison of intra- and interobserver agreement and variability using ultrasound and magnetic resonance imaging with two-dimensional measurements and three-dimensional whole fetal volume techniques
    Matthew, J.
    Knight, C.
    Malamateniou, C.
    Pasupathy, D.
    Rutherford, M.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 45 - 46
  • [32] Inter- and intra-observer variation of fetal volume measurements with three-dimensional ultrasound in the first trimester of pregnancy
    Smeets, Nicol A. C.
    van de Ven, Joost
    Oei, S. Guid
    JOURNAL OF PERINATAL MEDICINE, 2011, 39 (05) : 539 - 543
  • [33] Prenatal diagnosis of sirenomelia by two-dimensional and three-dimensional skeletal imaging ultrasound
    Rong Liu
    Xin-lin Chen
    Xiao-hong Yang
    Hui-jing Ma
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2015, 35 : 928 - 931
  • [34] Prenatal Diagnosis of Sirenomelia by Two-Dimensional and Three-Dimensional Skeletal Imaging Ultrasound
    刘蓉
    陈欣林
    杨小红
    马慧静
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2015, 35 (06) : 928 - 931
  • [35] Three-dimensional photoacoustic imaging with a clinical two-dimensional matrix ultrasound transducer
    Erpelding, Todd N.
    Wang, Yu
    Jankovic, Ladislav
    Guo, Zijian
    Robert, Jean-Luc
    David, Guillaume
    Kim, Chulhong
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011, 2011, 7899
  • [36] Prenatal Diagnosis of Sirenomelia by Two-Dimensional and Three-Dimensional Skeletal Imaging Ultrasound
    刘蓉
    陈欣林
    杨小红
    马慧静
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2015, (06) : 928 - 931
  • [37] Prenatal diagnosis of sirenomelia by two-dimensional and three-dimensional skeletal imaging ultrasound
    Liu, Rong
    Chen, Xin-lin
    Yang, Xiao-hong
    Ma, Hui-jing
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2015, 35 (06) : 928 - 931
  • [38] Intra- and inter-observer reliability using a noninvasive ultrasound cardiac output monitor in healthy anesthetized children
    Dhanani, Sonny
    Barrowman, Nick J.
    Ward, Roxanne E.
    Murto, Kimmo T.
    PEDIATRIC ANESTHESIA, 2011, 21 (08) : 858 - 864
  • [39] Two-Dimensional and Three-Dimensional Ultrasound of Artificial Skin
    Wortsman, Ximena
    Navarrete, Nelson
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (01) : 225 - 230
  • [40] A three-dimensional ultrasound prostate imaging system
    Tong, S
    Downey, DB
    Cardinal, HN
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (06): : 735 - 746