A comparison of standard two-dimensional ultrasound to three-dimensional volume sonography for routine second-trimester fetal imaging

被引:13
|
作者
Roy-Lacroix, M. E. [1 ,2 ]
Moretti, F. [1 ,3 ]
Ferraro, Z. M. [1 ,3 ,4 ]
Brosseau, L. [1 ]
Clancy, J. [1 ]
Fung-Kee-Fung, K. [1 ,3 ]
机构
[1] Univ Ottawa, Ottawa Hosp, Div Maternal Fetal Med, Dept Obstet Gynecol & Newborn Care, Ottawa, ON, Canada
[2] Univ Sherbrooke, Ctr Hosp Univ Sherbrooke, Dept Obstet & Gynecol, Sherbrooke, PQ, Canada
[3] Univ Ottawa, Fac Med, Ottawa, ON, Canada
[4] Ottawa Hosp, Res Inst, Ottawa, ON, Canada
关键词
PRENATAL-DIAGNOSIS; FEASIBILITY; ANOMALIES; TIME;
D O I
10.1038/jp.2016.212
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: In comparison with standard two-dimensional (2D) imaging of fetal structure and biometry, we aimed to evaluate the role of three-dimensional (3D) imaging as a screening tool in the mid-trimester. STUDY DESIGN: Pregnant women presenting between 18and 22 weeks for routine anatomical survey and biometric measurements were recruited. Six volumes of fetal anatomic regions were obtained and archived for later reconstruction, along with three volumes of extra-fetal structures (placenta, cervix, amniotic fluid). The 2D standard fetal images were then obtained. Offline reconstruction of 3D volumes was performed for comparative analysis (2D vs 3D). Subsequently, 3D volumes were reconstructed to mirror traditional 2D and allow biometric comparison between the two techniques. Data of 98 patients were analyzed. RESULTS: Complete visualization of vital anatomic structures was seen >= 85% of the time with 3D ultrasound. The 3D imaging improved the assessment of the four heart chambers (P=0.003), thoracic spine (P=0.008) and lumbar spine (P=0.012) views. The 2D imaging was superior for the fetal head, placenta and upper limbs. Conditional probabilities were used to assess the clinical value of 3D when standard 2D views were incomplete (mean 0.8830; 95% confidence interval 0.8059 to 0.9320). Overall diagnostic accuracy of 3D ultrasound is not superior for all fetal anatomic structures. Fetal biometric measurements assessed by both techniques demonstrated substantial to excellent agreement. CONCLUSION: The use of 3D imaging as a primary screening tool is limited and may be best utilized as a second-stage test. Overall, there is good correlation between fetal biometry assessed by either 2D or 3D technology.
引用
收藏
页码:380 / 386
页数:7
相关论文
共 50 条
  • [1] A comparison of standard two-dimensional ultrasound to three-dimensional volume sonography for routine second-trimester fetal imaging
    M E Roy-Lacroix
    F Moretti
    Z M Ferraro
    L Brosseau
    J Clancy
    K Fung-Kee-Fung
    [J]. Journal of Perinatology, 2017, 37 : 380 - 386
  • [2] Three-dimensional versus two-dimensional ultrasound for fetal nasal bone evaluation in the second trimester
    Papasozomenou, P.
    Athanasiadis, A. P.
    Zafrakas, M.
    Panteris, E.
    Loufopoulos, A.
    Assimakopoulos, E.
    Tarlatzis, B. C.
    [J]. JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2015, 28 (12): : 1432 - 1437
  • [3] Comparison of two-dimensional and three-dimensional sonography in evaluating fetal malformations
    Xu, HX
    Zhang, QP
    Lu, MD
    Xiao, XT
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 2002, 30 (09) : 515 - 525
  • [4] Normal and abnormal appearance of fetal ganglionic eminence on second-trimester three-dimensional ultrasound
    Contro, E.
    Volpe, N.
    Larcher, L.
    Dall'Asta, A.
    da Costa, M. A. Penas
    Vairo, G.
    di Pasquo, E.
    Giorgini, I.
    Ghi, T.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, : 398 - 404
  • [5] The influence of leptin on placental and fetal volume measured by three-dimensional ultrasound in the second trimester
    Woelfer, B
    Hafner, E
    Metzenbauer, M
    Schuchter, K
    Philipp, K
    [J]. PLACENTA, 2005, 26 (2-3) : 124 - 128
  • [6] Second-trimester evaluation of fetal sacrococcygeal teratoma using three-dimensional color Doppler ultrasound and magnetic resonance imaging
    Chen, CP
    Shih, JC
    Huang, JK
    Wang, WS
    Tzen, CY
    [J]. PRENATAL DIAGNOSIS, 2003, 23 (07) : 602 - 603
  • [7] Fetal biometry and estimated fetal weight in the second trimester: A comparison of intra- and interobserver agreement and variability using ultrasound and magnetic resonance imaging with two-dimensional measurements and three-dimensional whole fetal volume techniques
    Matthew, J.
    Knight, C.
    Malamateniou, C.
    Pasupathy, D.
    Rutherford, M.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 45 - 46
  • [8] Three-dimensional ultrasound assessment of fetal liver volume in normal pregnancy: A comparison of reproducibility with two-dimensional ultrasound and a search for a volume constant
    Chang, FM
    Hsu, KF
    Ko, HC
    Yao, BL
    Chang, CH
    Yu, CH
    Chen, HY
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03): : 381 - 389
  • [9] Three-dimensional ultrasonography of normal fetal heart: Comparison with two-dimensional imaging
    Department of Radiology, McGill University, Jewish General Hospital, Montreal, Que., Canada
    不详
    不详
    不详
    不详
    [J]. J. Ultrasound Med., 6 (341-348):
  • [10] Three-dimensional ultrasonography of normal fetal heart: Comparison with two-dimensional imaging
    Levental, M
    Pretorius, DH
    Sklansky, MS
    Budorick, NE
    Nelson, TR
    Lou, K
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 1998, 17 (06) : 341 - 348