Effect of range modulation on neutron dose equivalent exposures around a passive scattering proton therapy treatment nozzle

被引:0
|
作者
Polf, J [1 ]
Newhauser, W [1 ]
机构
[1] MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX USA
关键词
D O I
10.1118/1.1998668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of our study was to examine the influence of range modulation on the neutron dose equivalent exposures outside the treatment volume around a large‐field passively scattered proton therapy treatment nozzle. Method and Materials: In this study, the neutron dose equivalent spectra per proton (H(E/p)) and total neutron dose equivalent per therapeutic absorbed dose (H/D) were calculated using Monte Carlo simulations of the neutron fluence and the energy dependent neutron fluence‐to‐dose equivalent conversion factor for NCRP 38. (H(E)/p) and H/D were calculated at 54 locations around a passively scattered proton therapy treatment nozzle for varying amounts of range modulation. Results: As the step thickness of the range modulator wheel increased from 1.0 to 12.0 cm, the peak values of H(E)/p increased from 1⋅10−17 to 2⋅10−17 mSv/Gy at 50 cm from isocenter along the beam's central axis. In general, H/D increased with increasing range modulation at all locations studied, and the maximum H/D exposures shifted upstream of isocenter and away from the end of the nozzle. Conclusion: Several important findings can be summarized from the presented work. First, with increasing thickness of the RMW step, the high‐energy peak in the H(E)/p spectra shifted to higher energies. Second, at 90° with respect to the proton beam axis, the high‐energy peak occurs at substantially lower neutron energies. Also, the H/D values around the treatment nozzle increased as the modulation of the beam increased. Finally, the H/D values change significantly with distance from isocenter and angle with respect to the incident beam axis, due in part to the effects of the nozzle components on the neutron fluence downstream of the end of the nozzle. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2164 / 2164
页数:1
相关论文
共 50 条
  • [41] A novel approach to the optimization of beam current modulation for proton therapy beam using passive scattering
    Lu, H
    Kooy, H
    MEDICAL PHYSICS, 2005, 32 (06) : 2138 - 2138
  • [42] Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault
    Zheng, Yuanshui
    Newhauser, Wayne
    Klein, Eric
    Low, Daniel
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22): : 6943 - 6957
  • [43] Ambient neutron dose equivalent during proton therapy using wobbling scanning system: Measurements and calculations
    Lin, Yung-Chieh
    Lee, Chung-Chi
    Chao, Tsi-Chian
    Tsai, Hui-Yu
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 290 - 294
  • [44] Comparison between proton and neutron dose distributions from single-scattering and dual-scattering systems in ocular proton therapy
    Koch, N
    Newhauser, W
    MEDICAL PHYSICS, 2005, 32 (06) : 2028 - 2028
  • [45] Influence of beam efficiency through the patient-specific collimator on secondary neutron dose equivalent in double scattering and uniform scanning modes of proton therapy
    Hecksel, D.
    Anferov, V.
    Fitzek, M.
    Shahnazi, K.
    MEDICAL PHYSICS, 2010, 37 (06) : 2910 - 2917
  • [46] Neutron dose equivalent measurement for typical cranial and spinal treatments at MD Anderson Proton Treatment Center
    Wang, X.
    Gillin, M.
    Sahoo, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S144 - S145
  • [47] Quantification of Dose Uncertainties in DIR-Based Accumulated Dose Estimation On Prostate Passive-Scattering Proton Therapy
    Abe, Y.
    Kadoya, N.
    Arai, K.
    Takayama, Y.
    Kato, T.
    Kimura, K.
    Ono, T.
    Nakamura, T.
    Wada, H.
    Kikuchi, Y.
    Jingu, K.
    MEDICAL PHYSICS, 2017, 44 (06) : 3123 - 3123
  • [48] A SPHEROIDALLY SYMMETRIC TREATMENT OF NEUTRON-PROTON ELASTIC SCATTERING SHRINKAGE EFFECT
    ALMEIDA, SP
    LI, MC
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (04): : 636 - &
  • [49] Evaluation of the dosimetric effect of scattered protons in clinical practice in passive scattering proton therapy
    Kim, Chankyu
    Kim, Yeon-Joo
    Lee, Nuri
    Ahn, Sang Hee
    Kim, Kwang Hyeon
    Kim, Haksoo
    Shin, Dongho
    Lim, Young Kyung
    Jeong, Jong Hwi
    Kim, Dae Yong
    Shin, Wook-Geun
    Min, Chul Hee
    Lee, Se Byeong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 104 - 118
  • [50] Perturbation to dose distribution caused by utilizing an MLC instead of a brass aperture in passive scattering proton therapy
    Goulart, D.
    Maughan, R.
    McDonough, J.
    Bloch, P.
    Avery, S.
    Ainsley, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2481 - 2481