Influence of beam efficiency through the patient-specific collimator on secondary neutron dose equivalent in double scattering and uniform scanning modes of proton therapy

被引:23
|
作者
Hecksel, D. [1 ]
Anferov, V. [2 ]
Fitzek, M. [1 ]
Shahnazi, K. [1 ]
机构
[1] Indiana Univ, Sch Med, Midwest Proton Radiotherapy Inst, Bloomington, IN 47408 USA
[2] Indiana Univ, Cyclotron Facil, Bloomington, IN 47408 USA
关键词
proton therapy; neutrons; dose equivalent; MONTE-CARLO SIMULATIONS; PROSTATE-CANCER; STRAY RADIATION; 2ND CANCER; RISK; RADIOTHERAPY; EXPOSURES; IRRADIATION; MOTHER; SYSTEM;
D O I
10.1118/1.3431575
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Conventional proton therapy facilities use double scattering nozzles, which are optimized for delivery of a few fixed field sizes. Similarly, uniform scanning nozzles are commissioned for a limited number of field sizes. However, cases invariably occur where the treatment field is significantly different from these fixed field sizes. The purpose of this work was to determine the impact of the radiation field conformity to the patient-specific collimator on the secondary neutron dose equivalent. Methods: Using a WENDI-II neutron detector, the authors experimentally investigated how the neutron dose equivalent at a particular point of interest varied with different collimator sizes, while the beam spreading was kept constant. The measurements were performed for different modes of dose delivery in proton therapy, all of which are available at the Midwest Proton Radiotherapy Institute (MPRI): Double scattering, uniform scanning delivering rectangular fields, and uniform scanning delivering circular fields. The authors also studied how the neutron dose equivalent changes when one changes the amplitudes of the scanned field for a fixed collimator size. Results: The secondary neutron dose equivalent was found to decrease linearly with the collimator area for all methods of dose delivery. The relative values of the neutron dose equivalent for a collimator with a 5 cm diameter opening using 88 MeV protons were 1.0 for the double scattering field, 0.76 for rectangular uniform field, and 0.6 for the circular uniform field. Furthermore, when a single circle wobbling was optimized for delivery of a uniform field 5 cm in diameter, the secondary neutron dose equivalent was reduced by a factor of 6 compared to the double scattering nozzle. Additionally, when the collimator size was kept constant, the neutron dose equivalent at the given point of interest increased linearly with the area of the scanned proton beam. Conclusions: The results of these experiments suggest that the patient-specific collimator is a significant contributor to the secondary neutron dose equivalent to a distant organ at risk. Improving conformity of the radiation field to the patient-specific collimator can significantly reduce secondary neutron dose equivalent to the patient. Therefore, it is important to increase the number of available generic field sizes in double scattering systems as well as in uniform scanning nozzles. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3431575]
引用
收藏
页码:2910 / 2917
页数:8
相关论文
共 26 条
  • [1] Comparasion of Entrance Dose of Uniform Scanning and Double Scattering Modes in Proton Therapy
    Zhao, Z.
    Li, Z.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] The Effect of Proton Therapy Beam Scanning Pattern Size On Secondary Neutron Dose Equivalent
    Hecksel, D.
    Anferov, V.
    Shahnazi, K.
    Fitzek, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Utility of a patient-specific aperture collimator and multi-leaf collimator in line scanning proton therapy
    Ko, Mincheol
    Jeon, Chanil
    Ahn, Sung Hwan
    Han, Youngyih
    Chung, Kwangzoo
    Cho, Sungkoo
    Jo, Kwanghyun
    Shin, Eun Hyuk
    Lee, Sehyoung
    Lee, Woojin
    Oh, Yoonjin
    Kim, Juhye
    Kang, Seokyoon
    Park, Hee Chul
    Lee, Kisung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 85 (09) : 751 - 762
  • [4] Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams
    Zheng, Yuanshui
    Liu, Yaxi
    Zeidan, Omar
    Schreuder, Andries Niek
    Keole, Sameer
    MEDICAL PHYSICS, 2012, 39 (06) : 3484 - 3492
  • [5] Neutron Dose Equivalent Evaluation for Pencil Beam Scanning Proton Therapy with Apertures
    Geng, C.
    Schuemann, J.
    Moteabbed, M.
    Paganetti, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3466 - 3466
  • [6] Analytic Dose Verification for Patient-Specific Proton Pencil Beam Scanning Plans
    Chang, C.
    Mah, D.
    MEDICAL PHYSICS, 2015, 42 (06) : 3359 - 3359
  • [7] Potential Reduction in Out-Of-Field Dose in Pencil Beam Scanning Proton Therapy Through Use of a Patient-Specific Aperture
    Dowdell, S.
    Clasie, B.
    Depauw, N.
    Metcalfe, P.
    Rosenfeld, A.
    Kooy, H.
    Flanz, J.
    Paganetti, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3872 - 3872
  • [8] Efficient double-scattering proton therapy with a patient-specific bolus
    Zou, Wei
    Burgdorf, Brendan
    Yue, Ning J.
    Yin, Lingshu
    Zhang, Miao
    Khan, Atif
    Jabbour, Salma K.
    McDonough, James
    Dong, Lei
    Teo, Boon-Keng Kevin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 50 : 1 - 6
  • [9] An Evaluation and Quantification of Secondary Neutron Radiation Dose Due to Double Scatter and Pencil Beam Scanning Proton Therapy
    Glick, A.
    Diffenderfer, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [10] Evaluation of Secondary Neutron Dose Equivalent to a Point Representing a Fetus During Pencil Beam Scanning Proton Therapy Treatment of the Mother
    Hecksel, D.
    Pankuch, M.
    Gao, M.