Effect of range modulation on neutron dose equivalent exposures around a passive scattering proton therapy treatment nozzle

被引:0
|
作者
Polf, J [1 ]
Newhauser, W [1 ]
机构
[1] MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX USA
关键词
D O I
10.1118/1.1998668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of our study was to examine the influence of range modulation on the neutron dose equivalent exposures outside the treatment volume around a large‐field passively scattered proton therapy treatment nozzle. Method and Materials: In this study, the neutron dose equivalent spectra per proton (H(E/p)) and total neutron dose equivalent per therapeutic absorbed dose (H/D) were calculated using Monte Carlo simulations of the neutron fluence and the energy dependent neutron fluence‐to‐dose equivalent conversion factor for NCRP 38. (H(E)/p) and H/D were calculated at 54 locations around a passively scattered proton therapy treatment nozzle for varying amounts of range modulation. Results: As the step thickness of the range modulator wheel increased from 1.0 to 12.0 cm, the peak values of H(E)/p increased from 1⋅10−17 to 2⋅10−17 mSv/Gy at 50 cm from isocenter along the beam's central axis. In general, H/D increased with increasing range modulation at all locations studied, and the maximum H/D exposures shifted upstream of isocenter and away from the end of the nozzle. Conclusion: Several important findings can be summarized from the presented work. First, with increasing thickness of the RMW step, the high‐energy peak in the H(E)/p spectra shifted to higher energies. Second, at 90° with respect to the proton beam axis, the high‐energy peak occurs at substantially lower neutron energies. Also, the H/D values around the treatment nozzle increased as the modulation of the beam increased. Finally, the H/D values change significantly with distance from isocenter and angle with respect to the incident beam axis, due in part to the effects of the nozzle components on the neutron fluence downstream of the end of the nozzle. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2164 / 2164
页数:1
相关论文
共 50 条
  • [31] Reduction of superficial radiation dose with bolus in passive scattering proton beam therapy
    Kim, Yeon-Joo
    Kim, Chankyu
    Lee, Se Byeong
    Kim, Jae-Sung
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 69 - 76
  • [32] An Assessment of the Secondary Neutron Dose in the Passive Scattering Proton Beam Facility of the National Cancer Center
    Han, Sang-Eun
    Cho, Gyuseong
    Lee, Se Byeong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (04) : 801 - 809
  • [33] The development of a treatment control system for a passive scattering proton therapy installation
    Hofverberg, P.
    Bergerot, J. -M.
    Trimaud, R.
    Herault, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1002
  • [34] Relative Biological Effectiveness of Passive-Scattering Proton Therapy Using a Range Modulation Wheel at the Nagoya Proton Therapy Center: An In Vitro Study With 4 Cell Lines
    Iwata, H.
    Ogino, H.
    Iwana, M.
    Shibata, H.
    Yasui, K.
    Ueno, T.
    Toshito, T.
    Omachi, C.
    Mizoe, J.
    Shibamoto, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S642 - S642
  • [35] Monte Carlo Simulations of Neutron Ambient Dose Equivalent in a Novel Proton Therapy Facility Design
    Titt, Uwe
    Pera, Enzo
    Gillin, Michael T.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2020, 6 (04) : 29 - 37
  • [36] CONTRIBUTION TO NEUTRON FLUENCE AND NEUTRON ABSORBED DOSE FROM DOUBLE SCATTERING PROTON THERAPY SYSTEM COMPONENTS
    Perez-Andujar, A.
    Newhauser, W. D.
    DeLuca, P. M., Jr.
    NUCLEAR TECHNOLOGY, 2009, 168 (03) : 728 - 735
  • [37] Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy
    Wang, Xudong
    Charlton, Michael A.
    Esquivel, Carlos
    Eng, Tony Y.
    Li, Ying
    Papanikolaou, Nikos
    MEDICAL PHYSICS, 2013, 40 (09)
  • [38] AMBIENT DOSE EQUIVALENT VERSUS EFFECTIVE DOSE FOR QUANTIFYING STRAY RADIATION EXPOSURES TO A PATIENT RECEIVING PROTON THERAPY FOR PROSTATE CANCER
    Fontenot, Jonas D.
    Taddei, Phillip
    Zheng, Yuanshui
    Mirkovic, Dragan
    Newhauser, Wayne D.
    NUCLEAR TECHNOLOGY, 2009, 168 (01) : 173 - 177
  • [39] Evaluation of Secondary Neutron Dose Equivalent to a Point Representing a Fetus During Pencil Beam Scanning Proton Therapy Treatment of the Mother
    Hecksel, D.
    Pankuch, M.
    Gao, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E495 - E496
  • [40] 3D Printer Application in Proton Therapy: A Novel Method to Deliver Passive-Scattering Proton Beams with a Fixed Range and Modulation for SRS and SRT
    Ding, X.
    Witztum, A.
    Liang, X.
    Reiche, M.
    Lin, H.
    Teo, B.
    Yin, L.
    Fiene, J.
    McDonough, J.
    Kassaee, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 514 - 514