Effect of range modulation on neutron dose equivalent exposures around a passive scattering proton therapy treatment nozzle

被引:0
|
作者
Polf, J [1 ]
Newhauser, W [1 ]
机构
[1] MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX USA
关键词
D O I
10.1118/1.1998668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of our study was to examine the influence of range modulation on the neutron dose equivalent exposures outside the treatment volume around a large‐field passively scattered proton therapy treatment nozzle. Method and Materials: In this study, the neutron dose equivalent spectra per proton (H(E/p)) and total neutron dose equivalent per therapeutic absorbed dose (H/D) were calculated using Monte Carlo simulations of the neutron fluence and the energy dependent neutron fluence‐to‐dose equivalent conversion factor for NCRP 38. (H(E)/p) and H/D were calculated at 54 locations around a passively scattered proton therapy treatment nozzle for varying amounts of range modulation. Results: As the step thickness of the range modulator wheel increased from 1.0 to 12.0 cm, the peak values of H(E)/p increased from 1⋅10−17 to 2⋅10−17 mSv/Gy at 50 cm from isocenter along the beam's central axis. In general, H/D increased with increasing range modulation at all locations studied, and the maximum H/D exposures shifted upstream of isocenter and away from the end of the nozzle. Conclusion: Several important findings can be summarized from the presented work. First, with increasing thickness of the RMW step, the high‐energy peak in the H(E)/p spectra shifted to higher energies. Second, at 90° with respect to the proton beam axis, the high‐energy peak occurs at substantially lower neutron energies. Also, the H/D values around the treatment nozzle increased as the modulation of the beam increased. Finally, the H/D values change significantly with distance from isocenter and angle with respect to the incident beam axis, due in part to the effects of the nozzle components on the neutron fluence downstream of the end of the nozzle. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2164 / 2164
页数:1
相关论文
共 50 条
  • [11] Ambient neutron and photon dose equivalent H*(10) around a pencil beam scanning proton therapy facility
    Sharma, Dayananda Shamurailatpam
    Patro, Kartikeswar C. H.
    Padannayel, Noufal Manthala
    Arjunan, Manikandan
    Krishnan, Ganapathy
    Thiyagarajan, Rajesh
    Chilukuri, Srinivas
    Jalali, Rakesh
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1102):
  • [12] Dosimetric impact of range uncertainty in passive scattering proton therapy
    Liu, Ruirui
    Sun, Baozhou
    Zhang, Tiezhi
    Williamson, Jeffery F.
    O'Sullivan, Joseph A.
    Zhao, Tianyu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (05): : 6 - 14
  • [13] Effects of choice of the MLC material on neutron dose equivalent outside of the treatment field in proton therapy
    Goulart, D.
    Maughan, R.
    McDonough, J.
    Avery, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2198 - 2198
  • [14] A Time Dependent Model of a Passive Scattering Proton Therapy Nozzle Using TOPAS
    Chequers, M. H.
    Granville, D.
    Suzuki, K.
    Sawakuchi, G. O.
    MEDICAL PHYSICS, 2012, 39 (06) : 3718 - 3719
  • [15] Commissioning a passive-scattering proton therapy nozzle for accurate SOBP delivery
    Engelsman, M.
    Lu, H. -M.
    Herrup, D.
    Bussiere, M.
    Kooy, H. M.
    MEDICAL PHYSICS, 2009, 36 (06) : 2172 - 2180
  • [16] Effect of DIR uncertainty on prostate passive-scattering proton therapy dose accumulation
    Abe, Yoshitomo
    Kadoya, Noriyuki
    Arai, Kazuhiro
    Takayama, Yoshiki
    Kato, Takahiro
    Kimura, Kanako
    Ono, Takashi
    Nakamura, Tatsuya
    Wada, Hitoshi
    Kikuchi, Yasuhiro
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 : 113 - 120
  • [17] Scattered neutron dose equivalent to a fetus from proton therapy of the mother
    Roy, SC
    Sandison, GA
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 997 - 998
  • [18] Measurement of neutron dose equivalent to proton therapy patients outside of the proton radiation field
    Yan, X
    Titt, U
    Koehler, AM
    Newhauser, WD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 429 - 434
  • [19] Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies
    Yonai, Shunsuke
    Matsufuji, Naruhiro
    Kanai, Tatsuaki
    Matsui, Yuki
    Matsushita, Kaoru
    Yamashita, Haruo
    Numano, Masumi
    Sakae, Takeji
    Terunuma, Toshiyuki
    Nishio, Teiji
    Kohno, Ryosuke
    Akagi, Takashi
    MEDICAL PHYSICS, 2008, 35 (11) : 4782 - 4792
  • [20] Feasibility studies of a passive scatter proton therapy nozzle without a range modulator wheel
    Harvey, Mark C.
    Polf, Jerimy C.
    Smith, Alfred R.
    Mohan, Radhe
    MEDICAL PHYSICS, 2008, 35 (06) : 2243 - 2252