Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

被引:5
|
作者
Kim, Jun Ho [1 ]
Abdala-Junior, Reinaldo [1 ]
Munhoz, Luciana [1 ]
Cortes, Arthur Rodriguez Gonzalez [1 ,3 ]
Watanabe, Plauto Christopher Aranha [2 ]
Costa, Claudio [1 ]
Arita, Emiko Saito [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol, Field Publ Oral Hlth & Forens Dent, Ribeirao Preto, Brazil
[3] Univ Malta, Mater Dei Hosp, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
Peri-Implantitis; Dental Implants; Cone-Beam Computed Tomography; PERIAPICAL RADIOGRAPHY; IN-VITRO; DEHISCENCE; ARTIFACTS; ACCURACY;
D O I
10.5624/isd.2020.50.2.133
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mech- anically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods : Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm x 8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm x 8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results : High intraobserver and interobserver agreement was found (P < 0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56 +/- 0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion : Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss. (Imaging Sci Dent 2020; 50: 133-9)
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [41] Assessment of peri-implant defects at titanium and zirconium dioxide implants by means of periapical radiographs and cone beam computed tomography: An in-vitro examination
    Steiger-Ronay, Valerie
    Krcmaric, Zvonimir
    Schmidlin, Patrick R.
    Sahrmann, Philipp
    Wiedemeier, Daniel B.
    Benic, Goran I.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1195 - 1201
  • [42] Stability changes of dental implants according to the simulated peri-implant bone defects
    Park, Chan-Jin
    Lee, Mi-Ran
    Cho, Lee-Ra
    Yi, Yang-Jin
    Jung, Ho-Nyun
    ASBM7: ADVANCED BIOMATERIALS VII, 2007, 342-343 : 57 - +
  • [43] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Yanhua Lan
    Xiaoyuan Huang
    Mingxing Fan
    Huazhen Yu
    Zhijian Xie
    Yiqun Zhou
    Clinical Oral Investigations, 2022, 26 : 6347 - 6359
  • [44] Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard
    Corpas, Livia dos Santos
    Jacobs, Reinhilde
    Quirynen, Marc
    Huang, Yan
    Naert, Ignace
    Duyck, Joke
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) : 492 - 499
  • [45] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Lan, Yanhua
    Huang, Xiaoyuan
    Fan, Mingxing
    Yu, Huazhen
    Xie, Zhijian
    Zhou, Yiqun
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (10) : 6347 - 6359
  • [46] Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implantsAn in vitro study
    Hilgenfeld, Tim
    Juerchott, Alexander
    Deisenhofer, Ulrich Karl
    Krisam, Johannes
    Rammelsberg, Peter
    Heiland, Sabine
    Bendszus, Martin
    Schwindling, Franz Sebastian
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) : 922 - 930
  • [47] Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
    Magat, Guldane
    Oncu, Elif
    Ozcan, Sevgi
    Orhan, Kaan
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2022, 48 (01) : 41 - 49
  • [48] Quantitative measurement of peri-implant bone defects using optical coherence tomography
    Kim, Sulhee
    Kang, Se-Ryong
    Park, Hee-Jung
    Kim, Bome
    Kim, Tae-Il
    Yi, Won-Jin
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (02): : 84 - 91
  • [49] Detection Accuracy of Bone Defects Depending on Exposure Settings of Cone Beam Computed Tomography
    Vassilopoulos, Spyridon, I
    Bobetsis, Yiorgos A.
    Mastoris, Michalis
    Pepelassi, Eudoxie
    Nikopoulou-Karagianni, Keti
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2020, 40 (02) : E65 - E72
  • [50] Comparison of cone-beam computed tomography with multislice computed tomography in detection of small osseous condylar defects
    Jones, Elizabeth M.
    Papio, Melissa
    Tee, Boon Ching
    Beck, Frank M.
    Fields, Henry W.
    Sun, Zongyang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (01) : 130 - 139