Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

被引:5
|
作者
Kim, Jun Ho [1 ]
Abdala-Junior, Reinaldo [1 ]
Munhoz, Luciana [1 ]
Cortes, Arthur Rodriguez Gonzalez [1 ,3 ]
Watanabe, Plauto Christopher Aranha [2 ]
Costa, Claudio [1 ]
Arita, Emiko Saito [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol, Field Publ Oral Hlth & Forens Dent, Ribeirao Preto, Brazil
[3] Univ Malta, Mater Dei Hosp, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
Peri-Implantitis; Dental Implants; Cone-Beam Computed Tomography; PERIAPICAL RADIOGRAPHY; IN-VITRO; DEHISCENCE; ARTIFACTS; ACCURACY;
D O I
10.5624/isd.2020.50.2.133
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mech- anically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods : Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm x 8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm x 8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results : High intraobserver and interobserver agreement was found (P < 0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56 +/- 0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion : Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss. (Imaging Sci Dent 2020; 50: 133-9)
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [31] Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography-is this correct?
    Sabour, Siamak
    Dastjerdi, Elahe Vahid
    Moezizadeh, Maryam
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1785 - 1785
  • [32] More about accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Dongyun Wang
    Andreas Künzel
    Vladimir Golubovic
    Ilya Mihatovic
    Gordon John
    Zhuofan Chen
    Jürgen Becker
    Frank Schwarz
    Clinical Oral Investigations, 2013, 17 : 1787 - 1788
  • [33] More about accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Wang, Dongyun
    Kuenzel, Andreas
    Golubovic, Vladimir
    Mihatovic, Ilya
    John, Gordon
    Chen, Zhuofan
    Becker, Juergen
    Schwarz, Frank
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1787 - 1788
  • [34] The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review
    Sawicki, Pawel
    Zawadzki, Pawel J.
    Regulski, Piotr
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [35] Comprehensive peri-implant tissue evaluation with ultrasonography and cone-beam computed tomography: A pilot study
    Siqueira, Rafael
    Sinjab, Khaled
    Pan, Ying-Chun
    Soki, Fabiana
    Chan, Hsun-Liang
    Kripfgans, Oliver
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (07) : 777 - 785
  • [36] Comparison between cone-beam and multislice computed tomography for identification of simulated bone lesions
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Perrella, Andreia
    Fenyo-Pereira, Marlene
    Paraiso Cavalcanti, Marcelo Gusmao
    BRAZILIAN ORAL RESEARCH, 2011, 25 (04) : 362 - 368
  • [37] Evaluation of peri-implant buccal bone by computed tomography: an experimental study
    Gonzalez-Martin, Oscar
    Oteo, Carlos
    Ortega, Ricardo
    Alandez, Javier
    Sanz, Mariano
    Veltri, Mario
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (08) : 950 - 955
  • [38] Detection of peri-implant bone defects with different radiographic techniques - a human cadaver study
    Kuehl, Sebastian
    Zuercher, Silvia
    Zitzmann, Nicola U.
    Filippi, Andreas
    Payer, Michael
    Dagassan-Berndt, Dorothea
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (05) : 529 - 534
  • [39] Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study
    Silveira-Neto, Nicolau
    Flores, Mateus Ericson
    De Carli, Joao Paulo
    Costa, Max Doria
    Matos, Felipe de Souza
    Paranhos, Luiz Renato
    Sandini Linden, Maria Salete
    CLINICS, 2017, 72 (11) : 708 - 713
  • [40] Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study (vol 120, pg 69, 2015)
    Pinheiro, Lucas Rodrigues
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Umetsubo, Otavio Shoiti
    Santos Junior, Oseas
    Cavalcanti, Marcelo Gusmao
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (06): : 780 - 780