Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study

被引:6
|
作者
Silveira-Neto, Nicolau [1 ]
Flores, Mateus Ericson [1 ]
De Carli, Joao Paulo [1 ]
Costa, Max Doria [2 ]
Matos, Felipe de Souza [3 ]
Paranhos, Luiz Renato [4 ]
Sandini Linden, Maria Salete [1 ]
机构
[1] Univ Passo Fundo, Dept Odontol, Passo Fundo, RS, Brazil
[2] Univ Tiradentes, Dept Odontol, Aracaju, SE, Brazil
[3] Univ Estadual Paulista, Inst Ciencia & Tecnol, Dept Odontol Restauradora, Sao Jose Dos Campos, Brazil
[4] Univ Fed Sergipe, Dept Odontol, Lagarto, SE, Brazil
关键词
Artifacts; Cone Beam Computed Tomography; Dental Implants; ACCURACY;
D O I
10.6061/clinics/2017(11)10
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: This research evaluated detail registration in peri-implant bone using two different cone beam computer tomography systems and a digital periapical radiograph. METHODS: Three different image acquisition protocols were established for each cone beam computer tomography apparatus, and three clinical situations were simulated in an ex vivo fresh pig mandible: buccal bone defect, peri-implant bone defect, and bone contact. Data were subjected to two analyses: quantitative and qualitative. The quantitative analyses involved a comparison of real specimen measures using a digital caliper in three regions of the preserved buccal bone - A, B and E (control group) - to cone beam computer tomography images obtained with different protocols (kp1, kp2, kp3, ip1, ip2, and ip3). In the qualitative analyses, the ability to register peri-implant details via tomography and digital periapical radiography was verified, as indicated by twelve evaluators. Data were analyzed with ANOVA and Tukey's test (alpha=0.05). RESULTS: The quantitative assessment showed means statistically equal to those of the control group under the following conditions: buccal bone defect B and E with kp1 and ip1, peri-implant bone defect E with kp2 and kp3, and bone contact A with kp1, kp2, kp3, and ip2. Qualitatively, only bone contacts were significantly different among the assessments, and the p3 results differed from the p1 and p2 results. The other results were statistically equivalent. CONCLUSIONS: The registration of peri-implant details was influenced by the image acquisition protocol, although metal artifacts were produced in all situations. The evaluators preferred the Kodak 9000 3D cone beam computer tomography in most cases. The evaluators identified buccal bone defects better with cone beam computer tomography and identified peri-implant bone defects better with digital periapical radiography.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 50 条
  • [1] A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects
    Dave, Meetal
    Davies, Jonathan
    Wilson, Ron
    Palmer, Richard
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (06) : 671 - 678
  • [2] Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection
    Saberi, Bardia Vadiati
    Khosravifard, Negar
    Ghandari, Farnaz
    Hadinezhad, Arash
    IMAGING SCIENCE IN DENTISTRY, 2019, 49 (04) : 265 - 272
  • [3] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Mehmet Hakan Kurt
    Nilsun Bağış
    Cengiz Evli
    Cemal Atakan
    Kaan Orhan
    International Journal of Implant Dentistry, 6
  • [4] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Kurt, Mehmet Hakan
    Bagis, Nilsun
    Evli, Cengiz
    Atakan, Cemal
    Orhan, Kaan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [5] Effectiveness of Periapical Radiography Versus Cone Beam Computed Tomography with Different Kilovoltage Settings in the Detection of Chemically Created Peri-implant Bone Defects: An In Vitro Study
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Paraiso Cavalcanti, Marcelo Gusmao
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 741 - 750
  • [6] Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study
    Zhang, Chu-Nan
    Zhu, Yu
    Fan, Lin-Feng
    Zhang, Xiao
    Jiang, Yin-Hua
    Gu, Ying-Xin
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (03) : 948 - 956
  • [7] A Comparison of Cone Beam Computed Tomography and Panoramic Radiography in the Detection of Mechanical Created Peri-implant Bone Defects
    Naje, Ahmed R.
    F-Al Drobie, Ban
    Falah, Ali
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2019, 7 (01): : 222 - 225
  • [8] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Yanhua Lan
    Xiaoyuan Huang
    Mingxing Fan
    Huazhen Yu
    Zhijian Xie
    Yiqun Zhou
    Clinical Oral Investigations, 2022, 26 : 6347 - 6359
  • [9] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Lan, Yanhua
    Huang, Xiaoyuan
    Fan, Mingxing
    Yu, Huazhen
    Xie, Zhijian
    Zhou, Yiqun
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (10) : 6347 - 6359
  • [10] Assessment of peri-implant defects at titanium and zirconium dioxide implants by means of periapical radiographs and cone beam computed tomography: An in-vitro examination
    Steiger-Ronay, Valerie
    Krcmaric, Zvonimir
    Schmidlin, Patrick R.
    Sahrmann, Philipp
    Wiedemeier, Daniel B.
    Benic, Goran I.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1195 - 1201