Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study

被引:6
|
作者
Silveira-Neto, Nicolau [1 ]
Flores, Mateus Ericson [1 ]
De Carli, Joao Paulo [1 ]
Costa, Max Doria [2 ]
Matos, Felipe de Souza [3 ]
Paranhos, Luiz Renato [4 ]
Sandini Linden, Maria Salete [1 ]
机构
[1] Univ Passo Fundo, Dept Odontol, Passo Fundo, RS, Brazil
[2] Univ Tiradentes, Dept Odontol, Aracaju, SE, Brazil
[3] Univ Estadual Paulista, Inst Ciencia & Tecnol, Dept Odontol Restauradora, Sao Jose Dos Campos, Brazil
[4] Univ Fed Sergipe, Dept Odontol, Lagarto, SE, Brazil
关键词
Artifacts; Cone Beam Computed Tomography; Dental Implants; ACCURACY;
D O I
10.6061/clinics/2017(11)10
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: This research evaluated detail registration in peri-implant bone using two different cone beam computer tomography systems and a digital periapical radiograph. METHODS: Three different image acquisition protocols were established for each cone beam computer tomography apparatus, and three clinical situations were simulated in an ex vivo fresh pig mandible: buccal bone defect, peri-implant bone defect, and bone contact. Data were subjected to two analyses: quantitative and qualitative. The quantitative analyses involved a comparison of real specimen measures using a digital caliper in three regions of the preserved buccal bone - A, B and E (control group) - to cone beam computer tomography images obtained with different protocols (kp1, kp2, kp3, ip1, ip2, and ip3). In the qualitative analyses, the ability to register peri-implant details via tomography and digital periapical radiography was verified, as indicated by twelve evaluators. Data were analyzed with ANOVA and Tukey's test (alpha=0.05). RESULTS: The quantitative assessment showed means statistically equal to those of the control group under the following conditions: buccal bone defect B and E with kp1 and ip1, peri-implant bone defect E with kp2 and kp3, and bone contact A with kp1, kp2, kp3, and ip2. Qualitatively, only bone contacts were significantly different among the assessments, and the p3 results differed from the p1 and p2 results. The other results were statistically equivalent. CONCLUSIONS: The registration of peri-implant details was influenced by the image acquisition protocol, although metal artifacts were produced in all situations. The evaluators preferred the Kodak 9000 3D cone beam computer tomography in most cases. The evaluators identified buccal bone defects better with cone beam computer tomography and identified peri-implant bone defects better with digital periapical radiography.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 50 条
  • [41] Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences
    Lins de-Azevedo-Vaz, Sergio
    Peyneau, Priscila Dias
    Ramirez-Sotelo, Laura Ricardina
    Vasconcelos, Karla de Faria
    Flores Campos, Paulo Sergio
    Haiter-Neto, Francisco
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (05): : 550 - 556
  • [42] Measuring peri-implant bone lesions using low-dose cone-beam computed tomography
    Leisner, Laura Christine
    Tasaka, Akinori
    Trebing, Charlotte Theresa
    Hilgenfeld, Tim
    Kosinski, Matthias Adalbert
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    Schwindling, Franz Sebastian
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 326 - 332
  • [43] Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
    Alaa Shafiek Nomier
    Yousria Salah El-Din Gaweesh
    Maha R. Taalab
    Shaimaa Abu El Sadat
    BMC Oral Health, 22
  • [44] Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
    Nomier, Alaa Shafiek
    Gaweesh, Yousria Salah El-Din
    Taalab, Maha R. R.
    El Sadat, Shaimaa Abu
    BMC ORAL HEALTH, 2022, 22 (01)
  • [45] Accuracy of cone beam computed tomography and panoramic and periapical radiography for detection of apical periodontitis
    Estrela, Carlos
    Bueno, Mike Reis
    Leles, Claudio Rodrigues
    Azevedo, Bruno
    Azevedo, Jose Ribamar
    JOURNAL OF ENDODONTICS, 2008, 34 (03) : 273 - 279
  • [46] Accuracy of Cone-beam Computed Tomography and Periapical Radiography in Apical Periodontitis Diagnosis
    Lopez, Fernanda Ullmann
    Poli Kopper, Patricia Maria
    Cucco, Carolina
    Bona, Alvaro Della
    Poli de Figueiredo, Jose Antonio
    Vier-Pelisser, Fabiana Vieira
    JOURNAL OF ENDODONTICS, 2014, 40 (12) : 2057 - 2060
  • [47] An evaluation of the periapical status of teeth with necrotic pulps using periapical radiography and cone- beam computed tomography
    Abella, F.
    Patel, S.
    Duran-Sindreu, F.
    Mercade, M.
    Bueno, R.
    Roig, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (04) : 387 - 396
  • [48] Comparative Evaluation of Periapical Lesions Using Periapical Index Adapted for Panoramic Radiography and Cone Beam Computed Tomography
    Keser, Gaye
    Pekiner, Filiz Namdar
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2018, 8 (01): : 50 - 55
  • [49] Prognosis of root canal treatment in teeth with preoperative apical periodontitis: a study with cone-beam computed tomography and digital periapical radiography
    Restrepo-Restrepo, F. A.
    Canas-Jimenez, S. J.
    Romero-Albarracin, R. D.
    Villa-Machado, P. A.
    Perez-Cano, M. I.
    Tobon-Arroyave, S. I.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (11) : 1533 - 1546
  • [50] Pericervical Dentin Metrics in Mandibular First Molars Determined with Digital Periapical Radiography and Cone-beam Computed Tomography
    Boveda, Carlos
    Kishen, Anil
    Millan, Beatriz
    Camejo, Maria, V
    Gomez-Sosa, Jose Francisco
    JOURNAL OF ENDODONTICS, 2024, 50 (05) : 637 - 643