Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study

被引:6
|
作者
Silveira-Neto, Nicolau [1 ]
Flores, Mateus Ericson [1 ]
De Carli, Joao Paulo [1 ]
Costa, Max Doria [2 ]
Matos, Felipe de Souza [3 ]
Paranhos, Luiz Renato [4 ]
Sandini Linden, Maria Salete [1 ]
机构
[1] Univ Passo Fundo, Dept Odontol, Passo Fundo, RS, Brazil
[2] Univ Tiradentes, Dept Odontol, Aracaju, SE, Brazil
[3] Univ Estadual Paulista, Inst Ciencia & Tecnol, Dept Odontol Restauradora, Sao Jose Dos Campos, Brazil
[4] Univ Fed Sergipe, Dept Odontol, Lagarto, SE, Brazil
关键词
Artifacts; Cone Beam Computed Tomography; Dental Implants; ACCURACY;
D O I
10.6061/clinics/2017(11)10
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: This research evaluated detail registration in peri-implant bone using two different cone beam computer tomography systems and a digital periapical radiograph. METHODS: Three different image acquisition protocols were established for each cone beam computer tomography apparatus, and three clinical situations were simulated in an ex vivo fresh pig mandible: buccal bone defect, peri-implant bone defect, and bone contact. Data were subjected to two analyses: quantitative and qualitative. The quantitative analyses involved a comparison of real specimen measures using a digital caliper in three regions of the preserved buccal bone - A, B and E (control group) - to cone beam computer tomography images obtained with different protocols (kp1, kp2, kp3, ip1, ip2, and ip3). In the qualitative analyses, the ability to register peri-implant details via tomography and digital periapical radiography was verified, as indicated by twelve evaluators. Data were analyzed with ANOVA and Tukey's test (alpha=0.05). RESULTS: The quantitative assessment showed means statistically equal to those of the control group under the following conditions: buccal bone defect B and E with kp1 and ip1, peri-implant bone defect E with kp2 and kp3, and bone contact A with kp1, kp2, kp3, and ip2. Qualitatively, only bone contacts were significantly different among the assessments, and the p3 results differed from the p1 and p2 results. The other results were statistically equivalent. CONCLUSIONS: The registration of peri-implant details was influenced by the image acquisition protocol, although metal artifacts were produced in all situations. The evaluators preferred the Kodak 9000 3D cone beam computer tomography in most cases. The evaluators identified buccal bone defects better with cone beam computer tomography and identified peri-implant bone defects better with digital periapical radiography.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 50 条
  • [31] The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review
    Sawicki, Pawel
    Zawadzki, Pawel J.
    Regulski, Piotr
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [32] Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
    Magat, Guldane
    Oncu, Elif
    Ozcan, Sevgi
    Orhan, Kaan
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2022, 48 (01) : 41 - 49
  • [33] Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review
    Costa, J. A.
    Mendes, J. M.
    Salazar, F.
    Pacheco, J. J.
    Rompante, P.
    Camara, M. I.
    ORAL RADIOLOGY, 2023, 39 (03) : 455 - 466
  • [34] Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs
    Fienitz, Tim
    Schwarz, Frank
    Ritter, Lutz
    Dreiseidler, Timo
    Becker, Juergen
    Rothamel, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) : 882 - 887
  • [35] Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review
    J. A. Costa
    J. M. Mendes
    F. Salazar
    J. J. Pacheco
    P. Rompante
    M. I. Câmara
    Oral Radiology, 2023, 39 : 455 - 466
  • [36] Diagnostic performance of cone beam computed tomography in assessing peri-implant bone loss: A systematic review
    Pelekos, Georgios
    Acharya, Aneesha
    Tonetti, Maurizio S.
    Bornstein, Michael M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (05) : 443 - 464
  • [37] Comparison of Cone-Beam Computed Tomography and Periapical Radiography in Predicting Treatment Decision for Periapical Lesions: A Clinical Study
    Balasundaram, Ashok
    Shah, Punit
    Hoen, Michael M.
    Wheater, Michelle A.
    Bringas, Josef S.
    Gartner, Arnold
    Geist, James R.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [38] Efficacy of cone-beam computed tomography with modified gray-scale range versus digital periapical radiography for the assessment of bone-implant interface gaps
    Kajan, Zahra Dalili
    Abbasi, Sara
    Khosravifard, Negar
    Sigaroudi, Ali Khalighi
    Motevasseli, Safa
    ORAL RADIOLOGY, 2022, 38 (01) : 80 - 88
  • [39] Assessment of Penetrability for Different Endodontic Irrigation Activating Techniques Using Cone-Beam Computed Tomography and Periapical Digital Radiography-An In Vitro Study
    Abdelhafeez, Manal M.
    Alharbi, Afnan S.
    Srivastava, Swati
    Abdelaziz, Rehab
    Eldwakhly, Elzahraa
    Almohareb, Rahaf A.
    Algahtani, Fahda N.
    Soliman, Mai
    APPLIED SCIENCES-BASEL, 2023, 13 (13):
  • [40] Reliability and accuracy of intraoral radiography, cone beam CT, and dental MRI for evaluation of peri-implant bone lesions at zirconia implants-an ex vivo feasibility study
    Miotk, Nikolai
    Schwindling, Franz Sebastian
    Zidan, Moussa
    Juerchott, Alexander
    Rammelsberg, Peter
    Hosseini, Zahra
    Nittka, Mathias
    Heiland, Sabine
    Bendszus, Martin
    Hilgenfeld, Tim
    JOURNAL OF DENTISTRY, 2023, 130