Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review

被引:9
|
作者
Costa, J. A. [1 ]
Mendes, J. M. [2 ]
Salazar, F. [2 ]
Pacheco, J. J. [2 ]
Rompante, P. [2 ]
Camara, M. I. [1 ]
机构
[1] CESPU, Univ Inst Hlth Sci IUCS, Med & Oral Surg Dept, P-4585116 Gandra, Portugal
[2] CESPU, Univ Inst Hlth Sci IUCS, UNIPRO Oral Pathol & Rehabil Res Unit, P-4585116 Gandra, Portugal
关键词
CBCT; Cone-beam computed tomography; Dental implant; Peri-implant; Bone loss; PERIAPICAL RADIOGRAPHY; BUCCAL BONE; ACCURACY;
D O I
10.1007/s11282-023-00683-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of this work was to perform an integrative review of the inspection of peri-implant bone defects using cone beam computed tomography (CBCT). An electronic search was performed in the PubMed database using the following scientific terms: CBCT or Cone Beam computed tomography; dental implant; peri-implant; bone loss; defects. The survey identified 267 studies, of which 18 were considered relevant to this study. These studies provided important data taking into account the accuracy of cone beam computed tomography in the detection and measurement of peri-implant bone defects such as fenestrations, dehiscence and intraosseous circumferential defects. The effectiveness of CBCT in aiding in geometric bone calculations and in the diagnosis of peri-implant defects was influenced by factors such as artefacts, defect size, bone wall thickness, implant material, adjustment of acquisition parameters and observer experience. A not insignificant number of studies compared intraoral radiography to CBCT in the detection of peri-implant bone loss. CBCT was clearly superior to intraoral radiography in the detection of all peri-implant bone defects, except for defects located in the interproximal zone. In general, studies have shown that peri-implant bone measurements adjacent to the implant surface can be correctly determined, as well as the diagnosis of peri-implant bone defects with an average discrepancy of less than 1 mm from the actual measurement of the defect.
引用
收藏
页码:455 / 466
页数:12
相关论文
共 50 条
  • [1] Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review
    J. A. Costa
    J. M. Mendes
    F. Salazar
    J. J. Pacheco
    P. Rompante
    M. I. Câmara
    Oral Radiology, 2023, 39 : 455 - 466
  • [2] Evaluation of the accuracy of cone beam computed tomography (CBCT) in the detection of peri-implant fenestration
    Gholampour, Atefeh
    Mollaei, Melika
    Ehsani, Hodis
    Ghobadi, Fatemeh
    Hosseinnataj, Abolfazl
    Yazdani, Mehdi
    BMC ORAL HEALTH, 2024, 24 (01):
  • [3] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2014, (02) : 103 - 109
  • [4] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2014, 2 (02) : 103 - 109
  • [5] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Huang, Yan
    Van Dessel, Jeroen
    Depypere, Maarten
    EzEldeen, Mostafa
    Iliescu, Alexandru Andrei
    Dos Santos, Emanuela
    Lambrichts, Ivo
    Liang, Xin
    Jacobs, Reinhilde
    BONE RESEARCH, 2014, 2
  • [6] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2
  • [7] A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects
    Dave, Meetal
    Davies, Jonathan
    Wilson, Ron
    Palmer, Richard
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (06) : 671 - 678
  • [8] A Comparison of Cone Beam Computed Tomography and Panoramic Radiography in the Detection of Mechanical Created Peri-implant Bone Defects
    Naje, Ahmed R.
    F-Al Drobie, Ban
    Falah, Ali
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2019, 7 (01): : 222 - 225
  • [9] Diagnostic performance of cone beam computed tomography in assessing peri-implant bone loss: A systematic review
    Pelekos, Georgios
    Acharya, Aneesha
    Tonetti, Maurizio S.
    Bornstein, Michael M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (05) : 443 - 464
  • [10] Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study
    Kuusisto, Niina
    Abushahba, Faleh
    Syrjanen, Stina
    Huumonen, Sisko
    Vallittu, Pekka
    Narhi, Timo
    DENTOMAXILLOFACIAL RADIOLOGY, 2023, 52 (08)