Validating cone-beam computed tomography for peri-implant bone morphometric analysis

被引:28
|
作者
Huang, Yan [1 ,2 ,3 ]
Van Dessel, Jeroen [1 ,2 ]
Depypere, Maarten [4 ]
EzEldeen, Mostafa [1 ,2 ]
Iliescu, Alexandru Andrei [5 ]
Dos Santos, Emanuela [6 ]
Lambrichts, Ivo [7 ]
Liang, Xin [8 ]
Jacobs, Reinhilde [1 ,2 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Leuven, Belgium
[3] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Chengdu 610064, Peoples R China
[4] Katholieke Univ Leuven, ESAT PSI, Leuven, Belgium
[5] UMF Craiova, Fac Dent, Craiova, Romania
[6] Pontificia Univ Catolica Parana, Sch Dent, Curitiba, Parana, Brazil
[7] Hasselt Univ, Biomed Res Inst, Diepenbeek, Belgium
[8] Dalian Med Univ, Sch Stomatol, Dalian, Peoples R China
来源
BONE RESEARCH | 2014年 / 2卷
关键词
TRABECULAR BONE; CT; OSTEOPOROSIS; ARCHITECTURE; MICROSTRUCTURE; STANDARD; BIOPSIES;
D O I
10.1038/boneres.2014.10
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n=27 vs. without implants n=9) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 mu m) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (similar to 6 mu m) to obtain high contrast 2D images. By using CT An imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb. Th and Tb. Sp, lower BV/TV and Tb.N were found on CBCT images (P<0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r=0.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2014, (02) : 103 - 109
  • [2] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2014, 2 (02) : 103 - 109
  • [3] Validating cone-beam computed tomography for peri-implant bone morphometric analysis
    Yan Huang
    Jeroen Van Dessel
    Maarten Depypere
    Mostafa EzEldeen
    Alexandru Andrei Iliescu
    Emanuela Dos Santos
    Ivo Lambrichts
    Xin Liang
    Reinhilde Jacobs
    Bone Research, 2
  • [4] Measuring peri-implant bone lesions using low-dose cone-beam computed tomography
    Leisner, Laura Christine
    Tasaka, Akinori
    Trebing, Charlotte Theresa
    Hilgenfeld, Tim
    Kosinski, Matthias Adalbert
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    Schwindling, Franz Sebastian
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 326 - 332
  • [5] Efficacy of two radiographic algorithms for detection of peri-implant bone defects on cone-beam computed tomography scans
    Yousefi, Faezeh
    Heidari, Ali
    Ehsani, Azita
    Farhadian, Maryam
    Ehsani, Marzieh
    BMC ORAL HEALTH, 2025, 25 (01):
  • [6] The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review
    Sawicki, Pawel
    Zawadzki, Pawel J.
    Regulski, Piotr
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [7] Comprehensive peri-implant tissue evaluation with ultrasonography and cone-beam computed tomography: A pilot study
    Siqueira, Rafael
    Sinjab, Khaled
    Pan, Ying-Chun
    Soki, Fabiana
    Chan, Hsun-Liang
    Kripfgans, Oliver
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (07) : 777 - 785
  • [8] Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review
    Costa, J. A.
    Mendes, J. M.
    Salazar, F.
    Pacheco, J. J.
    Rompante, P.
    Camara, M. I.
    ORAL RADIOLOGY, 2023, 39 (03) : 455 - 466
  • [9] Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review
    J. A. Costa
    J. M. Mendes
    F. Salazar
    J. J. Pacheco
    P. Rompante
    M. I. Câmara
    Oral Radiology, 2023, 39 : 455 - 466
  • [10] Evaluation of peri-implant bone defects on cone-beam computed tomography and the diagnostic accuracy of detecting these defects on panoramic images
    Oshima, Takayuki
    Asaumi, Rieko
    Ogura, Shin
    Kawai, Taisuke
    IMAGING SCIENCE IN DENTISTRY, 2024, 54 (02) : 171 - 180