Validating cone-beam computed tomography for peri-implant bone morphometric analysis

被引:28
|
作者
Huang, Yan [1 ,2 ,3 ]
Van Dessel, Jeroen [1 ,2 ]
Depypere, Maarten [4 ]
EzEldeen, Mostafa [1 ,2 ]
Iliescu, Alexandru Andrei [5 ]
Dos Santos, Emanuela [6 ]
Lambrichts, Ivo [7 ]
Liang, Xin [8 ]
Jacobs, Reinhilde [1 ,2 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[2] Univ Hosp Leuven, Leuven, Belgium
[3] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Chengdu 610064, Peoples R China
[4] Katholieke Univ Leuven, ESAT PSI, Leuven, Belgium
[5] UMF Craiova, Fac Dent, Craiova, Romania
[6] Pontificia Univ Catolica Parana, Sch Dent, Curitiba, Parana, Brazil
[7] Hasselt Univ, Biomed Res Inst, Diepenbeek, Belgium
[8] Dalian Med Univ, Sch Stomatol, Dalian, Peoples R China
来源
BONE RESEARCH | 2014年 / 2卷
关键词
TRABECULAR BONE; CT; OSTEOPOROSIS; ARCHITECTURE; MICROSTRUCTURE; STANDARD; BIOPSIES;
D O I
10.1038/boneres.2014.10
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n=27 vs. without implants n=9) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 mu m) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (similar to 6 mu m) to obtain high contrast 2D images. By using CT An imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb. Th and Tb. Sp, lower BV/TV and Tb.N were found on CBCT images (P<0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r=0.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] The Accuracy of Cone-Beam Computed Tomography for Evaluating Bone Density and Cortical Bone Thickness at the Implant Site: Micro-Computed Tomography and Histologic Analysis
    Suttapreyasri, Srisurang
    Suapear, Pradipat
    Leepong, Narit
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (08) : 2026 - 2031
  • [42] Morphometric study of the greater palatine canal: cone-beam computed tomography
    O. Rapado-González
    J. A. Suárez-Quintanilla
    X. L. Otero-Cepeda
    A. Fernández-Alonso
    M. M. Suárez-Cunqueiro
    Surgical and Radiologic Anatomy, 2015, 37 : 1217 - 1224
  • [43] Morphometric study of the greater palatine canal: cone-beam computed tomography
    Rapado-Gonzalez, O.
    Suarez-Quintanilla, J. A.
    Otero-Cepeda, X. L.
    Fernandez-Alonso, A.
    Suarez-Cunqueiro, M. M.
    SURGICAL AND RADIOLOGIC ANATOMY, 2015, 37 (10) : 1217 - 1224
  • [44] Evaluation of peri-implant buccal bone by computed tomography: an experimental study
    Gonzalez-Martin, Oscar
    Oteo, Carlos
    Ortega, Ricardo
    Alandez, Javier
    Sanz, Mariano
    Veltri, Mario
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (08) : 950 - 955
  • [45] Impact of cone-beam computed tomography on implant planning and on prediction of implant size
    de Mello Pedroso, Ludmila Assuncao
    Garcia, Robson Rodrigues
    Rodrigues Leles, Jose Luiz
    Leles, Claudio Rodrigues
    Garcia Santos Silva, Maria Alves
    BRAZILIAN ORAL RESEARCH, 2014, 28 (01): : 46 - 53
  • [46] Morphometric analysis - Cone beam computed tomography to predict bone quality and quantity
    Hohlweg-Majert, B.
    Metzger, M. C.
    Kummer, T.
    Schulze, D.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2011, 39 (05) : 330 - 334
  • [47] Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study
    Silveira-Neto, Nicolau
    Flores, Mateus Ericson
    De Carli, Joao Paulo
    Costa, Max Doria
    Matos, Felipe de Souza
    Paranhos, Luiz Renato
    Sandini Linden, Maria Salete
    CLINICS, 2017, 72 (11) : 708 - 713
  • [48] Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences
    Lins de-Azevedo-Vaz, Sergio
    Peyneau, Priscila Dias
    Ramirez-Sotelo, Laura Ricardina
    Vasconcelos, Karla de Faria
    Flores Campos, Paulo Sergio
    Haiter-Neto, Francisco
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (05): : 550 - 556
  • [49] Quantitative Evaluation of Bone-Related Factors at the Implant Site by Cone-Beam Computed Tomography
    Vasegh Z.
    Safi Y.
    Amid R.
    Ahsaie M.G.
    Amiri M.J.
    Minooei Z.
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (01) : 33 - 43
  • [50] Efficacy of Cone-Beam Computed Tomography in Evaluating Bone Quality for Optimum Implant Treatment Planning
    Liu, Jie
    Chen, Huan-Yu
    DoDo, Hamza
    Yousef, Hadil
    Firestone, Allen R.
    Chaudhry, Jahanzeb
    Johnston, William M.
    Lee, Damian J.
    Emam, Hany A.
    Kim, Do-Gyoon
    IMPLANT DENTISTRY, 2017, 26 (03) : 405 - 411