Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review

被引:9
|
作者
Costa, J. A. [1 ]
Mendes, J. M. [2 ]
Salazar, F. [2 ]
Pacheco, J. J. [2 ]
Rompante, P. [2 ]
Camara, M. I. [1 ]
机构
[1] CESPU, Univ Inst Hlth Sci IUCS, Med & Oral Surg Dept, P-4585116 Gandra, Portugal
[2] CESPU, Univ Inst Hlth Sci IUCS, UNIPRO Oral Pathol & Rehabil Res Unit, P-4585116 Gandra, Portugal
关键词
CBCT; Cone-beam computed tomography; Dental implant; Peri-implant; Bone loss; PERIAPICAL RADIOGRAPHY; BUCCAL BONE; ACCURACY;
D O I
10.1007/s11282-023-00683-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of this work was to perform an integrative review of the inspection of peri-implant bone defects using cone beam computed tomography (CBCT). An electronic search was performed in the PubMed database using the following scientific terms: CBCT or Cone Beam computed tomography; dental implant; peri-implant; bone loss; defects. The survey identified 267 studies, of which 18 were considered relevant to this study. These studies provided important data taking into account the accuracy of cone beam computed tomography in the detection and measurement of peri-implant bone defects such as fenestrations, dehiscence and intraosseous circumferential defects. The effectiveness of CBCT in aiding in geometric bone calculations and in the diagnosis of peri-implant defects was influenced by factors such as artefacts, defect size, bone wall thickness, implant material, adjustment of acquisition parameters and observer experience. A not insignificant number of studies compared intraoral radiography to CBCT in the detection of peri-implant bone loss. CBCT was clearly superior to intraoral radiography in the detection of all peri-implant bone defects, except for defects located in the interproximal zone. In general, studies have shown that peri-implant bone measurements adjacent to the implant surface can be correctly determined, as well as the diagnosis of peri-implant bone defects with an average discrepancy of less than 1 mm from the actual measurement of the defect.
引用
收藏
页码:455 / 466
页数:12
相关论文
共 50 条
  • [41] Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences
    Lins de-Azevedo-Vaz, Sergio
    Peyneau, Priscila Dias
    Ramirez-Sotelo, Laura Ricardina
    Vasconcelos, Karla de Faria
    Flores Campos, Paulo Sergio
    Haiter-Neto, Francisco
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (05): : 550 - 556
  • [42] Evaluation of a metal artifact reduction algorithm and an optimization filter in the estimation of peri-implant dehiscence defects by using cone beam computed tomography: an in-vitro study
    Bayrak, Seval
    Orhan, Kaan
    Cakmak, Emine Sebnem Kursun
    Gorurgoz, Cansu
    Odabasi, Onur
    Yilmaz, Dervis
    Atakan, Cemal
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2020, 130 (02): : 209 - 216
  • [43] Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri-implant bone defects
    Song, Dandan
    Shujaat, Sohaib
    Vasconcelos, Karla de Faria
    Huang, Yan
    Politis, Constantinus
    Lambrichts, Ivo
    Jacobs, Reinhilde
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [44] Dental Implant Monitoring Using Resonance Frequency Analysis (RFA) and Cone Beam Computed Tomography (CBCT) Measurement
    Genisa, Maya
    Shuib, Solehuddin
    Rajion, Zainul Ahmad
    Mohamad, Dasmawati
    Arief, Erry Mochamad
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2020, 11 (05) : 1015 - 1024
  • [45] Assessment of peri-implant defects at titanium and zirconium dioxide implants by means of periapical radiographs and cone beam computed tomography: An in-vitro examination
    Steiger-Ronay, Valerie
    Krcmaric, Zvonimir
    Schmidlin, Patrick R.
    Sahrmann, Philipp
    Wiedemeier, Daniel B.
    Benic, Goran I.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1195 - 1201
  • [46] Assessment of bone density in edentulous maxillae using cone beam computed tomography (CBCT)
    Mansuy, Charlotte
    Saliba-Serre, Berengere
    Ruquet, Michel
    Raskin, Anne
    Hue, Olivier
    Silvestri, Frederic
    Mense, Chloe
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2024, 125 (05)
  • [47] Audiological correlates of cone beam computed tomography (CBCT) in cochlear implant recipients
    Rahman, Tayseer Taha Abdel
    Kader, Hesham Abd El Aty Abdel
    Aziz, Tougan Taha Abdel
    HEARING BALANCE AND COMMUNICATION, 2019, 17 (04) : 249 - 256
  • [48] Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study (vol 120, pg 69, 2015)
    Pinheiro, Lucas Rodrigues
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Umetsubo, Otavio Shoiti
    Santos Junior, Oseas
    Cavalcanti, Marcelo Gusmao
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (06): : 780 - 780
  • [49] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Yanhua Lan
    Xiaoyuan Huang
    Mingxing Fan
    Huazhen Yu
    Zhijian Xie
    Yiqun Zhou
    Clinical Oral Investigations, 2022, 26 : 6347 - 6359
  • [50] Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard
    Corpas, Livia dos Santos
    Jacobs, Reinhilde
    Quirynen, Marc
    Huang, Yan
    Naert, Ignace
    Duyck, Joke
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) : 492 - 499