Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

被引:5
|
作者
Kim, Jun Ho [1 ]
Abdala-Junior, Reinaldo [1 ]
Munhoz, Luciana [1 ]
Cortes, Arthur Rodriguez Gonzalez [1 ,3 ]
Watanabe, Plauto Christopher Aranha [2 ]
Costa, Claudio [1 ]
Arita, Emiko Saito [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol, Field Publ Oral Hlth & Forens Dent, Ribeirao Preto, Brazil
[3] Univ Malta, Mater Dei Hosp, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
Peri-Implantitis; Dental Implants; Cone-Beam Computed Tomography; PERIAPICAL RADIOGRAPHY; IN-VITRO; DEHISCENCE; ARTIFACTS; ACCURACY;
D O I
10.5624/isd.2020.50.2.133
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mech- anically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods : Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm x 8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm x 8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results : High intraobserver and interobserver agreement was found (P < 0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56 +/- 0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion : Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss. (Imaging Sci Dent 2020; 50: 133-9)
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [11] Evaluation of peri-implant bone defects on cone-beam computed tomography and the diagnostic accuracy of detecting these defects on panoramic images
    Oshima, Takayuki
    Asaumi, Rieko
    Ogura, Shin
    Kawai, Taisuke
    IMAGING SCIENCE IN DENTISTRY, 2024, 54 (02) : 171 - 180
  • [12] Evaluation of the accuracy of cone beam computed tomography (CBCT) in the detection of peri-implant fenestration
    Gholampour, Atefeh
    Mollaei, Melika
    Ehsani, Hodis
    Ghobadi, Fatemeh
    Hosseinnataj, Abolfazl
    Yazdani, Mehdi
    BMC ORAL HEALTH, 2024, 24 (01):
  • [13] Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection
    Saberi, Bardia Vadiati
    Khosravifard, Negar
    Ghandari, Farnaz
    Hadinezhad, Arash
    IMAGING SCIENCE IN DENTISTRY, 2019, 49 (04) : 265 - 272
  • [14] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Mehmet Hakan Kurt
    Nilsun Bağış
    Cengiz Evli
    Cemal Atakan
    Kaan Orhan
    International Journal of Implant Dentistry, 6
  • [15] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Kurt, Mehmet Hakan
    Bagis, Nilsun
    Evli, Cengiz
    Atakan, Cemal
    Orhan, Kaan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [16] Effectiveness of Periapical Radiography Versus Cone Beam Computed Tomography with Different Kilovoltage Settings in the Detection of Chemically Created Peri-implant Bone Defects: An In Vitro Study
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Paraiso Cavalcanti, Marcelo Gusmao
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 741 - 750
  • [17] Effect of Cone-Beam Computed Tomography Field of View and Acquisition Frame on the Detection of Chemically Simulated Peri-Implant Bone Loss In Vitro
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Cavalcanti, Marcelo Gusmao
    JOURNAL OF PERIODONTOLOGY, 2015, 86 (10) : 1159 - 1165
  • [18] Diagnostic performance of cone beam computed tomography in assessing peri-implant bone loss: A systematic review
    Pelekos, Georgios
    Acharya, Aneesha
    Tonetti, Maurizio S.
    Bornstein, Michael M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (05) : 443 - 464
  • [19] Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study
    Pinheiro, Lucas Rodrigues
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Umetsubo, Otavio Shoiti
    Santos, Oseas, Jr.
    Paraiso Cavalcanti, Marcelo Gusmao
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (01): : 69 - 77
  • [20] Higher Resolution in Cone Beam Computed Tomography Is Accompanied by Improved Bone Detection in Peri-implant Bone Despite Metal Artifact Presence
    Kerkfeld, Valentin
    Meyer, Ulrich
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1331 - 1338