Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

被引:5
|
作者
Kim, Jun Ho [1 ]
Abdala-Junior, Reinaldo [1 ]
Munhoz, Luciana [1 ]
Cortes, Arthur Rodriguez Gonzalez [1 ,3 ]
Watanabe, Plauto Christopher Aranha [2 ]
Costa, Claudio [1 ]
Arita, Emiko Saito [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol, Field Publ Oral Hlth & Forens Dent, Ribeirao Preto, Brazil
[3] Univ Malta, Mater Dei Hosp, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
Peri-Implantitis; Dental Implants; Cone-Beam Computed Tomography; PERIAPICAL RADIOGRAPHY; IN-VITRO; DEHISCENCE; ARTIFACTS; ACCURACY;
D O I
10.5624/isd.2020.50.2.133
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mech- anically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods : Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm x 8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm x 8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results : High intraobserver and interobserver agreement was found (P < 0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56 +/- 0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion : Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss. (Imaging Sci Dent 2020; 50: 133-9)
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [21] Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Wang, Dongyun
    Kuenzel, Andreas
    Golubovic, Vladimir
    Mihatovic, Ilya
    John, Gordon
    Chen, Zhuofan
    Becker, Juergen
    Schwarz, Frank
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (06) : 1601 - 1609
  • [22] Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Dongyun Wang
    Andreas Künzel
    Vladimir Golubovic
    Ilya Mihatovic
    Gordon John
    Zhuofan Chen
    Jürgen Becker
    Frank Schwarz
    Clinical Oral Investigations, 2013, 17 : 1601 - 1609
  • [23] Measuring peri-implant bone lesions using low-dose cone-beam computed tomography
    Leisner, Laura Christine
    Tasaka, Akinori
    Trebing, Charlotte Theresa
    Hilgenfeld, Tim
    Kosinski, Matthias Adalbert
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    Schwindling, Franz Sebastian
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 326 - 332
  • [24] Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study
    Zhang, Chu-Nan
    Zhu, Yu
    Fan, Lin-Feng
    Zhang, Xiao
    Jiang, Yin-Hua
    Gu, Ying-Xin
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (03) : 948 - 956
  • [25] Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences
    Lins de-Azevedo-Vaz, Sergio
    Peyneau, Priscila Dias
    Ramirez-Sotelo, Laura Ricardina
    Vasconcelos, Karla de Faria
    Flores Campos, Paulo Sergio
    Haiter-Neto, Francisco
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (05): : 550 - 556
  • [26] Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography—is this correct?
    Siamak Sabour
    Elahe Vahid Dastjerdi
    Maryam Moezizadeh
    Clinical Oral Investigations, 2013, 17 : 1785 - 1785
  • [27] Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs
    Fienitz, Tim
    Schwarz, Frank
    Ritter, Lutz
    Dreiseidler, Timo
    Becker, Juergen
    Rothamel, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) : 882 - 887
  • [28] Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
    Alaa Shafiek Nomier
    Yousria Salah El-Din Gaweesh
    Maha R. Taalab
    Shaimaa Abu El Sadat
    BMC Oral Health, 22
  • [29] Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
    Nomier, Alaa Shafiek
    Gaweesh, Yousria Salah El-Din
    Taalab, Maha R. R.
    El Sadat, Shaimaa Abu
    BMC ORAL HEALTH, 2022, 22 (01)
  • [30] Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study
    Kuusisto, Niina
    Abushahba, Faleh
    Syrjanen, Stina
    Huumonen, Sisko
    Vallittu, Pekka
    Narhi, Timo
    DENTOMAXILLOFACIAL RADIOLOGY, 2023, 52 (08)