A review of air conditioning energy performance in data centers

被引:182
|
作者
Ni, Jiacheng [1 ,2 ]
Bai, Xuelian [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Three Gorges Reservoir Reg Ecoenvironm, Minist Educ, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing 400045, Peoples R China
来源
关键词
Data center; Air conditioning; Energy performance; Energy efficiency; CENTER TEMPERATURE INCREASES; AIRSIDE ECONOMIZERS; FLOW DISTRIBUTION; PERFORATED TILES; COOLING SYSTEMS; DESIGN; CONSUMPTION; ENVIRONMENTS; MANAGEMENT; DATACENTER;
D O I
10.1016/j.rser.2016.09.050
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During the last years, many countries are experiencing rapid expansions in the number and. size of data centers to keep pace with their internet and cloud computing needs. High energy consumption of the data center has gradually attracted public attention. However, there are no common efficiency standards governing the design or operation of data centers and the associated air conditioning systems. And the statistical research on air conditioning energy performance is still sorely lacking. This paper presents a summary of 100 data centers air conditioning energy performance. Energy efficiency metrics and benchmarks are also provided so that operators can use these information to track the performance of and identify opportunities to reduce energy use of air conditioning systems in their data centers. The collected data from articles and reports show that the average of HVAC system effectiveness index is 1.44. More than half of the data centers' air conditioning systems are inefficient. In total, HVAC systems account for about 38% of facility energy consumption. The range for this usage was 21% for the most efficient system and 61% for the least efficient system. Moreover it would be necessary to review some currently available energy efficiency strategies such as economizer cycles, airflow optimization, energy management, and simulations tools. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:625 / 640
页数:16
相关论文
共 50 条
  • [1] REDUCING ENERGY USAGE IN DATA CENTERS THROUGH CONTROL OF ROOM AIR CONDITIONING UNITS
    Iyengar, Madhusudan
    Schmidt, Roger
    Caricari, Joe
    [J]. 2010 12TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 2010,
  • [2] Energy saving analysis of evaporative cooling composite air conditioning system for data centers
    Han, Zongwei
    Sun, Xiaoqing
    Wei, Haotian
    Ji, Qiang
    Xue, Da
    [J]. APPLIED THERMAL ENGINEERING, 2021, 186
  • [3] Modeling of air conditioning systems for cooling of data centers
    Anton, R
    Jonsson, H
    Palm, B
    [J]. ITHERM 2002: EIGHTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, PROCEEDINGS, 2002, : 552 - 558
  • [4] Energy efficiency optimization analysis for a cooling composite air conditioning system for internet data centers
    Li, Zhao
    Tong, Jihua
    Zheng, Zhuling
    Dong, Pengli
    Yang, Shangqing
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2024, 30 (09) : 1167 - 1181
  • [5] Energy Consumption and Energy Saving Analysis of Air-Conditioning Systems of Data Centers in Typical Cities in China
    Sun, Tiezhu
    Huang, Xiaojun
    Liang, Caihang
    Liu, Riming
    Yan, Yongcheng
    [J]. SUSTAINABILITY, 2023, 15 (10)
  • [6] Energy-saving Technique Targeting Chilled-water Air Conditioning Equipment in Data Centers
    Nakata, Tatsuya
    Kaneko, Shinichiro
    Yoshii, Ari
    Sekiguchi, Keisuke
    Yanagi, Masahide
    [J]. 2014 IEEE 36TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2014,
  • [7] AIR CONDITIONING - OPTIMIZING PERFORMANCE BY REDUCING ENERGY CONSUMPTION
    Chen, Chun-Wei
    Lee, Cheng-Wen
    Lin, Yu-Wei
    [J]. ENERGY & ENVIRONMENT, 2014, 25 (05) : 1019 - 1024
  • [8] Review of thermal energy storage for air conditioning systems
    Al-Abidi, Abduljalil A.
    Bin Mat, Sohif
    Sopian, K.
    Sulaiman, M. Y.
    Lim, C. H.
    Th, Abdulrahman
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (08): : 5802 - 5819
  • [9] Review of energy management for data centers in energy internet
    Feng, Cheng
    Wang, Yi
    Chen, Qixin
    Zhang, Xuan
    Luo, Gang
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (07): : 1 - 9
  • [10] Problems and Countermeasures of Air Conditioning Systems in Internet Data Centers in Xi'an city
    Yang, Xiaohong
    Wang, Zhiwei
    Jing, Xiang
    [J]. SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 594 - 597