REDUCING ENERGY USAGE IN DATA CENTERS THROUGH CONTROL OF ROOM AIR CONDITIONING UNITS

被引:0
|
作者
Iyengar, Madhusudan [1 ]
Schmidt, Roger [1 ]
Caricari, Joe [2 ]
机构
[1] IBM Corp, New York, NY USA
[2] Grubb Ellis Management Serv, New York, NY USA
关键词
data center; cooling; thermal management; raised floor; energy efficiency;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Information Technology data centers consume a large amount of electricity in the US and world-wide. Cooling has been found to contribute about one third of this energy use. The two primary contributors to the data center cooling energy use are the refrigeration chiller and the Computer Room Air Conditioning units (CRACs). There have been recent changes in specifications for the data center environmental envelopes as mandated by ASHRAE (American Society for Heating Refrigeration and Air Conditioning Engineers), one of which specifically pertains to the upper and lower bound of air temperatures at the inlet to servers that are housed in data center rooms. These changes have been put in place in part to address the desire for greater cooling energy efficiency of these facilities. This paper primarily focuses on the methodologies to reduce the energy usage of room air conditioning devices by exploiting these recent changes in standards for the equipment environmental envelope. A 22000 square foot (6706 m(2)) data center with 739 kilo Watt of IT load is used as a representative example for numerical CFD analyses using a commercial software package to demonstrate methodologies to reduce the cooling energy use of Information Technology data centers. Several test case simulations are used to enable the calculation of room level air temperature fields for varying design conditions such as different numbers of operational CRACs or the volumetric air flow rate setting of the CRACs. Computation of cooling energy is carried out using available vendor equipment information. The relationship between the reduction in energy usage in CRAC units and the server inlet air temperatures are quantified and a systematic methodology for CRAC shut off is proposed. The relative magnitude of reduction in data center cooling energy use from shutting off CRACs or reducing CRAC motor speeds is also compared with scenarios involving increases in refrigeration chiller plant water temperature set point.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Optimal and Distributed Automatic Discrete Control of Air Conditioning Units in Data Centers
    Bermudez, S. A.
    Hamann, H. F.
    Klein, L. J.
    Marianno, F. J.
    Claassen, A.
    [J]. 2015 31ST ANNUAL SEMICONDUCTOR THERMAL MEASUREMENT, MODELING & MANAGEMENT SYMPOSIUM (SEMI-THERM), 2015, : 13 - 18
  • [2] A review of air conditioning energy performance in data centers
    Ni, Jiacheng
    Bai, Xuelian
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 67 : 625 - 640
  • [3] Energy and economic analysis of the bypass method for the computer room air conditioning units of a small data center
    Erden, Hamza Salih
    Turkmen, Ismail
    [J]. JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2022, 37 (04): : 1883 - 1898
  • [4] Control and monitoring of air-conditioning units through cloud storage and control operations
    Aravind, Chockalingam Vaithilingam
    Majrani, Mohsen
    [J]. INTERNATIONAL JOURNAL OF GRID AND UTILITY COMPUTING, 2021, 12 (5-6) : 499 - 506
  • [5] Centralized monitoring and control of air conditioning units
    Sanikommu, Nimala
    Joshi, A. S.
    [J]. JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2009, 68 (11): : 934 - 939
  • [6] Reducing the Operational Cost of Cloud Data Centers through Renewable Energy
    Lagana, Demetrio
    Mastroianni, Carlo
    Meo, Michela
    Renga, Daniela
    [J]. ALGORITHMS, 2018, 11 (10)
  • [7] Dynamic Energy Storage Control for Reducing Electricity Cost in Data Centers
    Zhang, Shuben
    Yang, Jian
    Shi, Youkang
    Wu, Xiaomin
    Ran, Yongyi
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2015, 2015
  • [8] Energy saving analysis of evaporative cooling composite air conditioning system for data centers
    Han, Zongwei
    Sun, Xiaoqing
    Wei, Haotian
    Ji, Qiang
    Xue, Da
    [J]. APPLIED THERMAL ENGINEERING, 2021, 186
  • [9] Airflow distribution through perforated tiles in close proximity to computer room air-conditioning units
    Rambo, Jeffrey
    Nelson, Graham
    Joshi, Yogendra
    [J]. ASHRAE TRANSACTIONS 2007 VOL 113, PT 2, 2007, 113 : 124 - 135
  • [10] Modeling of air conditioning systems for cooling of data centers
    Anton, R
    Jonsson, H
    Palm, B
    [J]. ITHERM 2002: EIGHTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, PROCEEDINGS, 2002, : 552 - 558