Modeling of air conditioning systems for cooling of data centers

被引:4
|
作者
Anton, R [1 ]
Jonsson, H [1 ]
Palm, B [1 ]
机构
[1] Royal Inst Technol, Div Appl Thermodynam & Refrigerat, Dept Energy Technol, SE-10044 Stockholm, Sweden
关键词
cooling capacity; model; design; air mass flow and evaporator;
D O I
10.1109/ITHERM.2002.1012504
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cooling of data centers has emerged as an area of increasing importance in the field of electronics thermal management. As the packaging and power densities are steadily increasing, so will the need for efficient and reliable cooling systems. In this paper, a model of an air conditioning unit is described. The model offers considerable flexibility in terms of the ability to choose between different designs of heat exchangers (evaporators and condensers), and working media, and hence the model offers the possibility to optimize the design. The model is developed using EES (Engineering Equation Solver), a programming environment that provides the thermo-physical properties for the working media used. The heat transfer and pressure drop in the components are modeled using an integral approach, i.e. the overall behavior of each component is modeled. This approach has been proven to give adequate accuracy.
引用
收藏
页码:552 / 558
页数:7
相关论文
共 50 条
  • [1] Energy saving analysis of evaporative cooling composite air conditioning system for data centers
    Han, Zongwei
    Sun, Xiaoqing
    Wei, Haotian
    Ji, Qiang
    Xue, Da
    [J]. APPLIED THERMAL ENGINEERING, 2021, 186
  • [2] Research status and development trends of evaporative cooling air-conditioning technology in data centers
    Chu, Junjie
    Huang, Xiang
    [J]. Energy and Built Environment, 2023, 4 (01): : 86 - 110
  • [3] Energy efficiency optimization analysis for a cooling composite air conditioning system for internet data centers
    Li, Zhao
    Tong, Jihua
    Zheng, Zhuling
    Dong, Pengli
    Yang, Shangqing
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2024, 30 (09) : 1167 - 1181
  • [4] Problems and Countermeasures of Air Conditioning Systems in Internet Data Centers in Xi'an city
    Yang, Xiaohong
    Wang, Zhiwei
    Jing, Xiang
    [J]. SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 594 - 597
  • [5] OPTIMIZATION OF OUTSIDE AIR COOLING IN DATA CENTERS
    Kumari, Niru
    Shih, Rocky
    McReynolds, Alan
    Sharma, Ratnesh
    Christian, Tom
    Bash, Cullen
    [J]. PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 519 - 525
  • [6] Optimization of Water Consumption in Hybrid Evaporative Cooling Air Conditioning Systems for Data Center Cooling Applications
    Ndukaife, Theodore A.
    Nnanna, A. G. Agwu
    [J]. HEAT TRANSFER ENGINEERING, 2019, 40 (07) : 559 - 573
  • [7] Data Analysis and Modeling of Chilled Water Loops in Air Conditioning Systems
    Zhao, Zhida
    Yu, Nanyang
    Yu, Tao
    Zhang, Haofei
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2017, 2017
  • [8] Modeling of automobile air conditioning systems
    Li, Chung-Lun
    Chung, Shung-Luen
    Lee, Jing-Nang
    [J]. CCDC 2009: 21ST CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-6, PROCEEDINGS, 2009, : 974 - +
  • [9] Fault diagnosis based operation risk evaluation for air conditioning systems in data centers
    Zhu, Xu
    Du, Zhimin
    Jin, Xinqiao
    Chen, Zhijie
    [J]. BUILDING AND ENVIRONMENT, 2019, 163
  • [10] A review of air conditioning energy performance in data centers
    Ni, Jiacheng
    Bai, Xuelian
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 67 : 625 - 640