Energy Consumption and Energy Saving Analysis of Air-Conditioning Systems of Data Centers in Typical Cities in China

被引:1
|
作者
Sun, Tiezhu [1 ,2 ,3 ]
Huang, Xiaojun [1 ]
Liang, Caihang [2 ]
Liu, Riming [1 ]
Yan, Yongcheng [3 ]
机构
[1] Hualan Design & Consulting Grp, Nanning 530011, Peoples R China
[2] Guilin Univ Elect Technol, Sch Mechanoelect Engn, Guilin 541004, Peoples R China
[3] Xian Polytech Univ, Sch Urban Planning & Municipal Engn, Xian 710660, Peoples R China
关键词
data center; air-conditioning; PUE; meteorological data statistics; energy saving potential;
D O I
10.3390/su15107826
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The energy consumption status and energy saving potential of the air-conditioning systems of data centers in seven typical cities in China (Xinjiang, Beijing, Jinan, Shanghai, Nanning, Guilin, and Haikou), representing diverse climate regions, were studied. The power usage effectiveness (PUE) and cooling load factor (CLF) were taken as the evaluation indicators. First, the energy consumption situations of the existing air-conditioning systems were analyzed using an internship survey. Second, the meteorological data throughout the year for the seven cities were statistically analyzed. Then, two energy saving renovation schemes were proposed. The operating hours under different operating modes in the seven cities were calculated, and the PUE and energy saving potential of the two energy saving schemes were evaluated by taking the production of 15 degrees C chilled water as an example. This study provides an overall picture of the energy utilization status in the current Chinese data center market and provides solutions for improving the design of air-conditioning systems, with energy saving benefits.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] AIR-CONDITIONING SYSTEMS FOR ENERGY SAVING
    TOCHIMOTO, K
    MIYAZAKI, K
    TAKAKUSAGI, A
    [J]. JAPAN TELECOMMUNICATIONS REVIEW, 1979, 21 (04): : 391 - 401
  • [2] Testing for Energy Recovery Ventilators and Energy Saving Analysis with Air-Conditioning Systems
    Yang, Peng
    Li, Li
    Wang, Jianqin
    Huang, Guilin
    Peng, Jingli
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 438 - 445
  • [3] AIR-CONDITIONING AND PARTICLE FILTRATION SYSTEMS FOR ENERGY SAVING
    TAKENAMI, T
    OHMI, T
    FUKUDA, S
    [J]. SOLID STATE TECHNOLOGY, 1989, 32 (04) : 161 - 168
  • [4] Energy-saving technology of air-conditioning systems for datacenters
    [J]. Udagawa, Y, 1600, Nippon Telegraph and Telephone Corp. (12):
  • [5] Numerical analysis of an air-conditioning energy-saving mechanism
    Huang, K. David
    Nguyen Anh Tuan
    [J]. BUILDING SIMULATION, 2010, 3 (01) : 63 - 73
  • [6] Energy saving strategies in air-conditioning for museums
    Ascione, Fabrizio
    Bellia, Laura
    Capozzoli, Alfonso
    Minichiello, Francesco
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (04) : 676 - 686
  • [7] Numerical analysis of an air-conditioning energy-saving mechanism
    K. David Huang
    Nguyen Anh Tuan
    [J]. Building Simulation, 2010, 3 : 63 - 73
  • [8] The Energy Consumption Investigation of the Hotel Central Air-conditioning System and the Research of Energy Saving Measures
    Ni, Jiajia
    Tao, Li
    Wang, Yijun
    Wu, Jinlei
    [J]. ADVANCES IN MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-4, 2013, 712-715 : 1614 - 1618
  • [9] Research on Air-conditioning Operation Energy Saving in Internet Data Center
    Cai, Jiaxing
    Yu, Wenhong
    Xu, Weiwei
    Wang, Kuan
    [J]. 2022 8TH INTERNATIONAL CONFERENCE ON HYDRAULIC AND CIVIL ENGINEERING: DEEP SPACE INTELLIGENT DEVELOPMENT AND UTILIZATION FORUM, ICHCE, 2022, : 1273 - 1276
  • [10] Water-cooled air-conditioning systems for energy and power saving
    Suri, R.K.
    Al-Marafie, A.M.R.
    Maheshwari, G.P.
    [J]. International Journal of Ambient Energy, 1989, 10 (03) : 123 - 128