Water-cooled air-conditioning systems for energy and power saving

被引:0
|
作者
Suri, R.K. [1 ]
Al-Marafie, A.M.R. [1 ]
Maheshwari, G.P. [1 ]
机构
[1] Energy Dep, Kuwait
关键词
Buildings--Air Conditioning;
D O I
暂无
中图分类号
学科分类号
摘要
The paper presents the results of an experimental investigation to compare the performance of water-cooled and air-cooled air-conditioning systems. Two identical chilled water air-conditioning systems, incorporating air-cooled and water-cooled condensers, were used independently to supply the cooling demand of a space. All other components of the two chillers were identical and of the same make. The chillers were operated on alternate days and their cooling production, power and energy needs were measured for the 24 hour period on a day-to-day basis during the summer of 1988. The results show that the water-cooled system requires 40% less peak power and 25% lower electrical energy. The energy requirements can be reduced further if seawater is used for condenser cooling in place of desalinated seawater.
引用
收藏
页码:123 / 128
相关论文
共 50 条
  • [1] AIR-CONDITIONING SYSTEMS FOR ENERGY SAVING
    TOCHIMOTO, K
    MIYAZAKI, K
    TAKAKUSAGI, A
    [J]. JAPAN TELECOMMUNICATIONS REVIEW, 1979, 21 (04): : 391 - 401
  • [2] The Power Simulation of Water-Cooled Central Air-Conditioning System Based on Demand Response
    Kang, Ligai
    Wang, Gang
    Wang, Yongzhen
    An, Qingsong
    [J]. IEEE ACCESS, 2020, 8 : 67396 - 67407
  • [3] A study on the energy performance of three schemes for widening application of water-cooled air-conditioning systems in Hong Kong
    Yik, FWH
    Burnett, J
    Prescott, I
    [J]. ENERGY AND BUILDINGS, 2001, 33 (02) : 167 - 182
  • [4] AIR-CONDITIONING AND PARTICLE FILTRATION SYSTEMS FOR ENERGY SAVING
    TAKENAMI, T
    OHMI, T
    FUKUDA, S
    [J]. SOLID STATE TECHNOLOGY, 1989, 32 (04) : 161 - 168
  • [5] Application of water-cooled air-conditioning for high-rise residential buildings
    Chen Hua
    Di Qianqian
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 8, 2010, : 27 - 36
  • [6] Energy saving through evaporatively cooled condenser air in conventional air-conditioning units
    [J]. Mathur, A.C., 1600, Publ by Ambient Press Ltd, Lutterworth, United Kingdom (15):
  • [7] Energy-saving technology of air-conditioning systems for datacenters
    [J]. Udagawa, Y., 1600, Nippon Telegraph and Telephone Corp. (12):
  • [8] A dynamic mathematical model of a direct expansion (DX) water-cooled air-conditioning plant
    Deng, SM
    [J]. BUILDING AND ENVIRONMENT, 2000, 35 (07) : 603 - 613
  • [9] Economic comparison of direct evaporative and common water-cooled central air-conditioning system
    Guan, WJ
    Li, LP
    Wang, SL
    [J]. ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 1072 - 1074
  • [10] PERSONAL CONDITIONING WITH AIR AND WATER-COOLED SUITS
    SHORT, BC
    BEENY, MJ
    CAMP, G
    [J]. ERGONOMICS, 1968, 11 (04) : 408 - &