Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CT

被引:16
|
作者
Hwang, Hye Jeon [1 ,2 ]
Seo, Joon Beom [1 ,2 ]
Lee, Jin Seong [1 ,2 ]
Song, Jae-Woo [1 ,2 ]
Kim, Song Soo [3 ]
Lee, Hyun Joo [1 ,2 ]
Lim, Chae Hun [1 ,2 ,4 ]
机构
[1] Univ Ulsan, Coll Med, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Res Inst Radiol, Asan Med Ctr, Seoul 138736, South Korea
[3] Chungnam Natl Univ, Sch Med, Chungnam Natl Univ Hosp, Dept Radiol, Taejon 301721, South Korea
[4] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Radiol, Seoul 137701, South Korea
关键词
Iterative reconstruction in image space; Chest CT; Radiation dose reduction; Image quality; COMPUTED-TOMOGRAPHY; EXPOSURE; THORAX;
D O I
10.3348/kjr.2012.13.6.711
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine whether the image quality (IQ) is improved with iterative reconstruction in image space (IRIS), and whether IRIS can be used for radiation reduction in chest CT. Materials and Methods: Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying a dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from a single tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Objective noise was measured. The subjective IQ was evaluated by radiologists for the followings: noise, contrast and sharpness of mediastinum and lung. Results: Objective noise was significantly lower in H-IRIS than in F-FBP (p < 0.01). In both SDCT and LDCT, the IQ scores were highest in F-IRIS, followed by F-FBP, H-IRIS and H-FBP, except those for sharpness of mediastinum, which tended to be higher in FBP. When comparing CT images between the same dose and different reconstruction (F-IRIS/F-FBP and H-IRIS/H-FBP) algorithms, scores tended to be higher in IRIS than in FBP, being more distinct in half-dose images. However, despite the use of IRIS, the scores were lower in H-IRIS than in F-FBP. Conclusion: IRIS generally helps improve the IQ, being more distinct at the reduced radiation. However, reduced radiation by half results in IQ decrease even when using IRIS in chest CT.
引用
收藏
页码:711 / 719
页数:9
相关论文
共 50 条
  • [31] Potential dose reduction and image quality improvement in chest CT with a photon-counting CT compared to a new dual-source CT
    Greffier, Joel
    Dabli, Djamel
    Faby, Sebastian
    Pastor, Maxime
    de Oliveira, Fabien
    Croisille, Cedric
    Erath, Julien
    Beregi, Jean-Paul
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 127
  • [32] Adaptive Iterative Dose Reduction in coronary CT angiography using 320-row CT: Assessment of radiation dose reduction and image quality
    Tomizawa, Nobuo
    Nojo, Takeshi
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 318 - 324
  • [33] Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique
    Kim, Jun-Hwee
    Kim, Myung-Joon
    Kim, Ha Yan
    Lee, Mi-Jung
    CLINICAL IMAGING, 2014, 38 (05) : 710 - 714
  • [34] CT colonography with spectral filtration and advanced modeled iterative reconstruction in the thirdgeneration dual-source CT: image quality, radiation dose and performance in clinical utility
    Liu, Jing-juan
    Xue, Hua-dan
    Liu, Wei
    Yan, Jing
    Pan, Wei-dong
    Li, Bin
    Xu, Kai
    Wang, Yun
    Li, Ping
    Xiao, Yi
    Jin, Zheng-yu
    ACADEMIC RADIOLOGY, 2021, 28 (05) : E127 - E136
  • [35] Image Quality and Dose Reduction Evaluation of a New CT Iterative Reconstruction Algorithm Using Model Observers
    Tseng, H.
    Fan, J.
    Kupinski, M.
    Sainath, P.
    Hsieh, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [36] Image quality guided iterative reconstruction for low-dose CT based on CT image statistics
    Duan, Jiayu
    Mou, Xuanqin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [37] Comparison study of image quality between filtered back projection and iterative reconstruction algorithm for dose reduction in chest CT
    Son, Junyoung
    Lee, Donghoon
    Jeon, Pil-Hyun
    Choi, Sunghoon
    Kim, Hyemi
    Kim, Hee-Joung
    INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [38] Image quality and radiation dose of CT venography with double dose reduction using model based iterative reconstruction: comparison with conventional CT venography using filtered back projection
    Jeong, Yeo-Jin
    Choo, Ki Seok
    Nam, Kyung Jin
    Lee, Ji Won
    Kim, Jin You
    Jung, Hyuk Jae
    Lim, Soo Jin
    ACTA RADIOLOGICA, 2018, 59 (05) : 546 - 552
  • [39] Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies
    Paprottka, Karolin J.
    Kupfer, Karina
    Schultz, Vivian
    Beer, Meinrad
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    Sollmann, Nico
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [40] Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies
    Karolin J. Paprottka
    Karina Kupfer
    Vivian Schultz
    Meinrad Beer
    Claus Zimmer
    Thomas Baum
    Jan S. Kirschke
    Nico Sollmann
    Scientific Reports, 13