Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CT

被引:16
|
作者
Hwang, Hye Jeon [1 ,2 ]
Seo, Joon Beom [1 ,2 ]
Lee, Jin Seong [1 ,2 ]
Song, Jae-Woo [1 ,2 ]
Kim, Song Soo [3 ]
Lee, Hyun Joo [1 ,2 ]
Lim, Chae Hun [1 ,2 ,4 ]
机构
[1] Univ Ulsan, Coll Med, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Res Inst Radiol, Asan Med Ctr, Seoul 138736, South Korea
[3] Chungnam Natl Univ, Sch Med, Chungnam Natl Univ Hosp, Dept Radiol, Taejon 301721, South Korea
[4] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Radiol, Seoul 137701, South Korea
关键词
Iterative reconstruction in image space; Chest CT; Radiation dose reduction; Image quality; COMPUTED-TOMOGRAPHY; EXPOSURE; THORAX;
D O I
10.3348/kjr.2012.13.6.711
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine whether the image quality (IQ) is improved with iterative reconstruction in image space (IRIS), and whether IRIS can be used for radiation reduction in chest CT. Materials and Methods: Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying a dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from a single tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Objective noise was measured. The subjective IQ was evaluated by radiologists for the followings: noise, contrast and sharpness of mediastinum and lung. Results: Objective noise was significantly lower in H-IRIS than in F-FBP (p < 0.01). In both SDCT and LDCT, the IQ scores were highest in F-IRIS, followed by F-FBP, H-IRIS and H-FBP, except those for sharpness of mediastinum, which tended to be higher in FBP. When comparing CT images between the same dose and different reconstruction (F-IRIS/F-FBP and H-IRIS/H-FBP) algorithms, scores tended to be higher in IRIS than in FBP, being more distinct in half-dose images. However, despite the use of IRIS, the scores were lower in H-IRIS than in F-FBP. Conclusion: IRIS generally helps improve the IQ, being more distinct at the reduced radiation. However, reduced radiation by half results in IQ decrease even when using IRIS in chest CT.
引用
收藏
页码:711 / 719
页数:9
相关论文
共 50 条
  • [21] The impact of iterative reconstruction on image quality and radiation dose in thoracic and abdominal CT
    Kalmar, Peter I.
    Quehenberger, Franz
    Steiner, Juergen
    Lutfi, Andre
    Bohlsen, Dennis
    Talakic, Emina
    Hassler, Eva Maria
    Schoellnast, Helmut
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (08) : 1416 - 1420
  • [22] Optimization of Radiation Dose and Image Quality in Musculoskeletal CT: Emphasis on Iterative Reconstruction Techniques (Part 1)
    Omoumi, Patrick
    Becce, Fabio
    Ott, Julien G.
    Racine, Damien
    Verdun, Francis R.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (05) : 415 - 421
  • [23] Sinogram-Affirmed Iterative Reconstruction of Low-Dose Chest CT: Effect on Image Quality and Radiation Dose
    Kalra, Mannudeep K.
    Woisetschlaeger, Mischa
    Dahlstroem, Nils
    Singh, Sarabjeet
    Digumarthy, Subbarao
    Do, Synho
    Pien, Homer
    Quick, Petter
    Schmidt, Bernhard
    Sedlmair, Martin
    Shepard, Jo-Anne O.
    Persson, Anders
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) : W235 - W244
  • [24] Dose reduction and image quality in CT examinations using an iterative reconstruction algorithm: a phantom study
    Guariglia, S.
    Meliado, G.
    Zivelonghi, E.
    Pinali, L.
    Montemezzi, S.
    Cavedon, C.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [25] Hybrid iterative reconstruction algorithm in brain CT: a radiation dose reduction and image quality assessment study
    Love, Askell
    Siemund, Roger
    Hoglund, Peter
    Van Westen, Danielle
    Stenberg, Lars
    Petersen, Cecilia
    Bjorkman-Burtscher, Isabella M.
    ACTA RADIOLOGICA, 2014, 55 (02) : 208 - 217
  • [26] Cranial CT with Adaptive Statistical Iterative Reconstruction: Improved Image Quality with Concomitant Radiation Dose Reduction
    Rapalino, O.
    Kamalian, Shervin
    Kamalian, Shahmir
    Payabvash, S.
    Souza, L. C. S.
    Zhang, D.
    Mukta, J.
    Sahani, D. V.
    Lev, M. H.
    Pomerantz, S. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) : 609 - 615
  • [27] Evaluation of image quality and radiation dose by adaptive statistical iterative reconstruction technique level for chest CT examination
    Hong, Sun Suk
    Lee, Jong-Woong
    Seo, Jeong Beom
    Jung, Jae-Eun
    Choi, Jiwon
    Kweon, Dae Cheol
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (02) : 163 - 171
  • [28] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Haesung Yoon
    Myung-Joon Kim
    Choon-Sik Yoon
    Jiin Choi
    Hyun Joo Shin
    Hyun Gi Kim
    Mi-Jung Lee
    Pediatric Radiology, 2015, 45 : 337 - 344
  • [29] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Yoon, Haesung
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Choi, Jiin
    Shin, Hyun Joo
    Kim, Hyun Gi
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (03) : 337 - 344
  • [30] Image reconstruction and image quality evaluation for a dual source CT scanner
    Flohr, T. G.
    Bruder, H.
    Stierstorfer, K.
    Petersilka, M.
    Schmidt, B.
    McCollough, C. H.
    MEDICAL PHYSICS, 2008, 35 (12) : 5882 - 5897