Image quality guided iterative reconstruction for low-dose CT based on CT image statistics

被引:5
|
作者
Duan, Jiayu [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Image Proc & Pattern Recognit, Xian 710049, Shaanxi, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 18期
基金
中国国家自然科学基金;
关键词
the regularization parameter; CT IQA; image quality guided reconstruction; REGULARIZATION PARAMETERS; FACTORIZATION; OPTIMIZATION; SURE;
D O I
10.1088/1361-6560/ac1b1b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Iterative reconstruction frameworks show predominance in low dose and incomplete data situations. In the iterative reconstruction framework, there are two components, i.e., the fidelity term aims to maintain the structure details of the reconstructed object, and the regularization term uses prior information to suppress the artifacts such as noise. A regularization parameter balances them, aiming to find a good trade-off between noise and resolution. Currently, the regularization parameters are selected as a rule of thumb or some prior knowledge assumption is required, which limits practical uses. Furthermore, the computation cost of regularization parameter selection is also heavy. In this paper, we address this problem by introducing CT image quality assessment (IQA) into the iterative reconstruction framework. Several steps are involved during the study. First, we analyze the CT image statistics using the dual dictionary (DDL) method. Regularities are observed and concluded, revealing the relationship among the regularization parameter, iterations, and CT image quality. Second, with derivation and simplification of DDL procedure, a CT IQA metric named SODVAC is designed. The SODVAC locates the optimal regularization parameter that results in the reconstructed image with distinct structures and with no noise or little noise. Thirdly, we introduce SODVAC into the iterative reconstruction framework and then propose a general image-quality-guided iterative reconstruction (QIR) framework and give a specific framework example (sQIR) by introducing SODVAC into the iterative reconstruction framework. sQIR simultaneously optimizes the reconstructed image and the regularization parameter during the iterations. Results confirm the effectiveness of the proposed method. No prior information is needed and the low computation cost are the advantages of our method compared with existing state-of-the-art L-curve and ZIP selection strategies.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Impact of iterative reconstruction on image quality of low-dose CT of the lumbar spine
    Alshamari, Muhammed
    Geijer, Mats
    Norrman, Eva
    Liden, Mats
    Krauss, Wolfgang
    Jendeberg, Johan
    Magnuson, Anders
    Geijer, Hakan
    ACTA RADIOLOGICA, 2017, 58 (06) : 702 - 709
  • [2] Image Quality Assessment of Low-Dose CT using Hybrid Iterative Reconstruction
    Zhang, Qiao
    Sheng, Jinhua
    Chen, Bin
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2021, 65 (06)
  • [3] Investigation of iterative image reconstruction in low-dose breast CT
    Bian, Junguo
    Yang, Kai
    Boone, John M.
    Han, Xiao
    Sidky, Emil Y.
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2659 - 2685
  • [4] Low-dose CT iterative reconstruction based on image block classification and dictionary learning
    Gui, Yunjia
    Zhao, Xia
    Bai, Yunjiao
    Zhao, Rongge
    Li, Wenqiang
    Liu, Yi
    SIGNAL IMAGE AND VIDEO PROCESSING, 2023, 17 (02) : 407 - 415
  • [5] Low-dose CT iterative reconstruction based on image block classification and dictionary learning
    Yunjia Gui
    Xia Zhao
    Yunjiao Bai
    Rongge Zhao
    Wenqiang Li
    Yi Liu
    Signal, Image and Video Processing, 2023, 17 : 407 - 415
  • [6] Pediatric low-dose head CT: Image quality improvement using iterative model reconstruction
    Rabinowich, Aviad
    Shendler, Genady
    Ben-Sira, Liat
    Shiran, Shelly, I
    NEURORADIOLOGY JOURNAL, 2023, 36 (05): : 555 - 562
  • [7] CT for evaluation of urolithiasis: image quality of ultralow-dose (Sub mSv) CT with knowledge-based iterative reconstruction and diagnostic performance of low-dose CT with statistical iterative reconstruction
    Joonho Hur
    Sung Bin Park
    Jong Beum Lee
    Hyun Jeong Park
    In Ho Chang
    Jong Kyou Kwon
    Yang Soo Kim
    Abdominal Imaging, 2015, 40 : 2432 - 2440
  • [8] CT for evaluation of urolithiasis: image quality of ultralow-dose (Sub mSv) CT with knowledge-based iterative reconstruction and diagnostic performance of low-dose CT with statistical iterative reconstruction
    Hur, Joonho
    Park, Sung Bin
    Lee, Jong Beum
    Park, Hyun Jeong
    Chang, In Ho
    Kwon, Jong Kyou
    Kim, Yang Soo
    ABDOMINAL IMAGING, 2015, 40 (07): : 2432 - 2440
  • [9] CT FOR EVALUATION OF UROLITHIASIS: IMAGE QUALITY OF ULTRALOW-DOSE (SUB MSV) CT WITH KNOWLEDGE-BASED ITERATIVE RECONSTRUCTION AND DIAGNOSTIC PERFORMANCE OF LOW-DOSE CT WITH STATISTICAL ITERATIVE RECONSTRUCTION
    Kim, Jin Wook
    Moon, Young Tae
    Kim, Kyung Do
    Kim, Tae-Hyoung
    Myung, Soon Chul
    Ahn, Seung Hyun
    Choi, Jae Duck
    Kim, Jung Hoon
    Kim, Min Soo
    Lee, Shin Young
    Chi, Byung Hoon
    Chang, In Ho
    JOURNAL OF UROLOGY, 2016, 195 (04): : E1079 - E1079
  • [10] Image quality improvement in low-dose chest CT with deep learning image reconstruction
    Tian, Qian
    Li, Xinyu
    Li, Jianying
    Cheng, Yannan
    Niu, Xinyi
    Zhu, Shumeng
    Xu, Wenting
    Guo, Jianxin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):