Image quality guided iterative reconstruction for low-dose CT based on CT image statistics

被引:5
|
作者
Duan, Jiayu [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Image Proc & Pattern Recognit, Xian 710049, Shaanxi, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 18期
基金
中国国家自然科学基金;
关键词
the regularization parameter; CT IQA; image quality guided reconstruction; REGULARIZATION PARAMETERS; FACTORIZATION; OPTIMIZATION; SURE;
D O I
10.1088/1361-6560/ac1b1b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Iterative reconstruction frameworks show predominance in low dose and incomplete data situations. In the iterative reconstruction framework, there are two components, i.e., the fidelity term aims to maintain the structure details of the reconstructed object, and the regularization term uses prior information to suppress the artifacts such as noise. A regularization parameter balances them, aiming to find a good trade-off between noise and resolution. Currently, the regularization parameters are selected as a rule of thumb or some prior knowledge assumption is required, which limits practical uses. Furthermore, the computation cost of regularization parameter selection is also heavy. In this paper, we address this problem by introducing CT image quality assessment (IQA) into the iterative reconstruction framework. Several steps are involved during the study. First, we analyze the CT image statistics using the dual dictionary (DDL) method. Regularities are observed and concluded, revealing the relationship among the regularization parameter, iterations, and CT image quality. Second, with derivation and simplification of DDL procedure, a CT IQA metric named SODVAC is designed. The SODVAC locates the optimal regularization parameter that results in the reconstructed image with distinct structures and with no noise or little noise. Thirdly, we introduce SODVAC into the iterative reconstruction framework and then propose a general image-quality-guided iterative reconstruction (QIR) framework and give a specific framework example (sQIR) by introducing SODVAC into the iterative reconstruction framework. sQIR simultaneously optimizes the reconstructed image and the regularization parameter during the iterations. Results confirm the effectiveness of the proposed method. No prior information is needed and the low computation cost are the advantages of our method compared with existing state-of-the-art L-curve and ZIP selection strategies.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Patient dose and image quality in low-dose abdominal CT: a comparison between iterative reconstruction and filtered back projection
    Kataria, Bharti
    Smedby, Orjan
    ACTA RADIOLOGICA, 2013, 54 (05) : 540 - 548
  • [22] Application of low-dose CT in image-guided radiotherapy based on CT-linac
    Yang, Jingru
    Liang, Yongguang
    Yang, Bo
    Zhang, Wenjun
    Leng, Lingxuan
    Wang, Jiaxin
    Zhu, Heling
    He, Shumeng
    Liao, Can
    Qiu, Jie
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (03)
  • [23] Iterative CT reconstruction in abdominal low-dose CT used for hybrid SPECT-CT applications: effect on image quality, image noise, detectability, and reader's confidence
    Grosser, Oliver S.
    Ruf, Juri
    Kupitz, Dennis
    Czuczwara, Damian
    Loewenthal, David
    Thormann, Markus
    Furth, Christian
    Ricke, Jens
    Denecke, Timm
    Pech, Maciej
    Kreissl, Michael C.
    Amthauer, Holger
    ACTA RADIOLOGICA OPEN, 2019, 8 (06):
  • [24] Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    So Won Lee
    Yookyung Kim
    Sung Shine Shim
    Jeong Kyong Lee
    Seok Jeong Lee
    Yon Ju Ryu
    Jung Hyun Chang
    European Radiology, 2014, 24 : 817 - 826
  • [25] Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    Lee, So Won
    Kim, Yookyung
    Shim, Sung Shine
    Lee, Jeong Kyong
    Lee, Seok Jeong
    Ryu, Yon Ju
    Chang, Jung Hyun
    EUROPEAN RADIOLOGY, 2014, 24 (04) : 817 - 826
  • [26] Deep Learning-Based Reconstruction Improves the Image Quality of Low-Dose CT Colonography
    Chen, Yanshan
    Huang, Zixuan
    Feng, Lijuan
    Zou, Wenbin
    Kong, Decan
    Zhu, Dongyun
    Dai, Guochao
    Zhao, Weidong
    Zhang, Yuanke
    Luo, Mingyue
    ACADEMIC RADIOLOGY, 2024, 31 (08) : 3191 - 3199
  • [27] Low-dose CT Reconstruction Assisted by a Global CT Image Manifold Prior
    Shen, Chenyang
    Ma, Guoyang
    Jia, Xun
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [28] An efficient low-dose CT reconstruction technique using partial derivatives based guided image filter
    Pathak, Yadunath
    Arya, K. V.
    Tiwari, Shailendra
    MULTIMEDIA TOOLS AND APPLICATIONS, 2019, 78 (11) : 14733 - 14752
  • [29] An efficient low-dose CT reconstruction technique using partial derivatives based guided image filter
    Yadunath Pathak
    K. V. Arya
    Shailendra Tiwari
    Multimedia Tools and Applications, 2019, 78 : 14733 - 14752
  • [30] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Damiano Caruso
    Domenico De Santis
    Antonella Del Gaudio
    Gisella Guido
    Marta Zerunian
    Michela Polici
    Daniela Valanzuolo
    Dominga Pugliese
    Raffaello Persechino
    Antonio Cremona
    Luca Barbato
    Andrea Caloisi
    Elsa Iannicelli
    Andrea Laghi
    European Radiology, 2024, 34 : 2384 - 2393