Application of low-dose CT in image-guided radiotherapy based on CT-linac

被引:0
|
作者
Yang, Jingru [1 ]
Liang, Yongguang [1 ]
Yang, Bo [1 ]
Zhang, Wenjun [1 ]
Leng, Lingxuan [1 ]
Wang, Jiaxin [1 ]
Zhu, Heling [1 ]
He, Shumeng [2 ]
Liao, Can [3 ]
Qiu, Jie [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[2] United Imaging Res Inst Intelligent Imaging, Beijing 100094, Peoples R China
[3] Shanghai United Imaging Healthcare Co Ltd, Shanghai 201807, Peoples R China
关键词
Fan-beam CT; Image-guided radiotherapy; Low-dose CT; Image quality; ITERATIVE RECONSTRUCTION;
D O I
10.1016/j.jrras.2024.101034
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Image-guided radiation therapy (IGRT) involves online medical imaging systems. CT-guided imaging systems not only have high image quality but also allow for direct dose calculation for radiation treatment planning, making it an ideal image guidance method. However, the imaging dose from CT images may pose additional risks to patients. Therefore, the aim of this study was to evaluate the substitutability of using low-dose CT images for IGRT. Materials and methods: The CIRS-062 phantom, Catphan 604 phantom, CT dose index phantom were used to obtain the conversion curves of the CT values to the relative electron density (RED), image quality, and imaging dose of the low-dose CT, respectively. Catphan 604 phantom and clinical cases were used to analyze the feasibility of low-dose CT for dose calculation. Results: No significant differences were observed in the conversion curves of CT values to RED between low-dose and standard-dose CT scans. In terms of image quality, the geometric distortion of low-dose CT was 0.1 mm, which was the same as that of standard-dose CT. The spatial resolution of the images was 0.42-0.45 lp/mm, which was slightly better than that of standard-dose CT (0.40-0.44 lp/mm). The image uniformity was 98.4%- 99.0%, slightly worse than that of standard-dose CT (99.4%-99.5%), but still met the clinical requirements. The imaging dose was 2.96-4.62 mGy, significantly lower than that of standard-dose CT (9.71-26.68 mGy), especially for head CT protocol. In terms of dose calculation, the gamma passing rates were not lower than 98% for either the Catphan 604 phantom or the clinical cases. Conclusion: Low-dose CT can significantly reduce the imaging dose without a significant loss of image quality and can be directly used for dose calculation in radiation treatment planning, providing a safer and more effective image guidance method for IGRT.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Image quality guided iterative reconstruction for low-dose CT based on CT image statistics
    Duan, Jiayu
    Mou, Xuanqin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [2] Low dose cone beam CT for paediatric image-guided radiotherapy: how much dose is enough?
    Bryce-Atkinson, A.
    De Jong, R.
    Marchant, T.
    Whitfield, G.
    Aznar, M. C.
    Bel, A.
    van Herk, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S588 - S589
  • [3] Low dose cone beam CT for paediatric image-guided radiotherapy: Image quality and practical recommendations
    Bryce-Atkinson, Abigail
    De Jong, Rianne
    Marchant, Tom
    Whitfield, Gillian
    Aznar, Marianne C.
    Bel, Arjan
    van Herk, Marcel
    RADIOTHERAPY AND ONCOLOGY, 2021, 163 : 68 - 75
  • [4] simulation of low-dose cone beam CT for paediatric image-guided proton beam therapy
    Lindsay, J.
    Bryce-Atkinson, A.
    Meara, S.
    Lines, D.
    van Herk, M.
    Aznar, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1402 - S1404
  • [5] The Dosimetric Performance of Online Adaptive Radiotherapy Based On CT-LINAC for Cervical Cancer
    Jiang, D.
    Yang, C.
    Mei, Z.
    Gong, J.
    Liu, H.
    Qiu, H.
    Wang, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E714 - E715
  • [6] Virtual CT-LINAC combination for extracranial stereotactic radiosurgery and radiotherapy
    Wurm, RE
    Scheffler, D
    Schlenger, L
    Ahlswede, J
    Pfaender, M
    Sommer, B
    RADIOLOGY, 2001, 221 : 223 - 223
  • [7] Patient dose in KV cone-beam CT image-guided radiotherapy
    Islam, M
    Purdie, T
    Moseley, D
    Alasti, H
    Norrlinger, B
    Sharpe, M
    Siewerdsen, J
    Jaffray, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1830 - 1830
  • [8] Quantitative evaluation of ultra-low dose paediatric cone beam CT for image-guided radiotherapy
    Bryce-Atkinson, A.
    De Jong, R.
    Bel, A.
    Aznar, M. C.
    Whitfield, G.
    Van Herk, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S965 - S966
  • [9] Enhanced Guided Image Filtering for the Processing of the Low-Dose CT Images
    Long B.-Y.
    Li K.
    Lü F.-J.
    Lü Z.-W.
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2019, 47 (07): : 1490 - 1496
  • [10] Deep learning-based projection synthesis for low-dose CBCT imaging in image-guided radiotherapy
    Zhao, Xuzhi
    Du, Yi
    Yue, Haizhen
    Wang, Ruoxi
    Zhou, Shun
    Wu, Hao
    Wang, Wei
    Peng, Yahui
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 231 - 250