Application of low-dose CT in image-guided radiotherapy based on CT-linac

被引:0
|
作者
Yang, Jingru [1 ]
Liang, Yongguang [1 ]
Yang, Bo [1 ]
Zhang, Wenjun [1 ]
Leng, Lingxuan [1 ]
Wang, Jiaxin [1 ]
Zhu, Heling [1 ]
He, Shumeng [2 ]
Liao, Can [3 ]
Qiu, Jie [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[2] United Imaging Res Inst Intelligent Imaging, Beijing 100094, Peoples R China
[3] Shanghai United Imaging Healthcare Co Ltd, Shanghai 201807, Peoples R China
关键词
Fan-beam CT; Image-guided radiotherapy; Low-dose CT; Image quality; ITERATIVE RECONSTRUCTION;
D O I
10.1016/j.jrras.2024.101034
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Image-guided radiation therapy (IGRT) involves online medical imaging systems. CT-guided imaging systems not only have high image quality but also allow for direct dose calculation for radiation treatment planning, making it an ideal image guidance method. However, the imaging dose from CT images may pose additional risks to patients. Therefore, the aim of this study was to evaluate the substitutability of using low-dose CT images for IGRT. Materials and methods: The CIRS-062 phantom, Catphan 604 phantom, CT dose index phantom were used to obtain the conversion curves of the CT values to the relative electron density (RED), image quality, and imaging dose of the low-dose CT, respectively. Catphan 604 phantom and clinical cases were used to analyze the feasibility of low-dose CT for dose calculation. Results: No significant differences were observed in the conversion curves of CT values to RED between low-dose and standard-dose CT scans. In terms of image quality, the geometric distortion of low-dose CT was 0.1 mm, which was the same as that of standard-dose CT. The spatial resolution of the images was 0.42-0.45 lp/mm, which was slightly better than that of standard-dose CT (0.40-0.44 lp/mm). The image uniformity was 98.4%- 99.0%, slightly worse than that of standard-dose CT (99.4%-99.5%), but still met the clinical requirements. The imaging dose was 2.96-4.62 mGy, significantly lower than that of standard-dose CT (9.71-26.68 mGy), especially for head CT protocol. In terms of dose calculation, the gamma passing rates were not lower than 98% for either the Catphan 604 phantom or the clinical cases. Conclusion: Low-dose CT can significantly reduce the imaging dose without a significant loss of image quality and can be directly used for dose calculation in radiation treatment planning, providing a safer and more effective image guidance method for IGRT.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Image-Guided Percutaneous Calvarial Biopsy with Low-Dose CT-Fluoroscopy: Technique, Safety, and Utility in 12 Patients
    Sundararajan, Sri Hari
    Cox, Mougnyan
    Sedora-Roman, Neda
    Ranganathan, Srirajkumar
    Hurst, Robert
    Pukenas, Bryan
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (01) : 134 - 136
  • [22] Image-Guided Percutaneous Calvarial Biopsy with Low-Dose CT-Fluoroscopy: Technique, Safety, and Utility in 12 Patients
    Sri Hari Sundararajan
    Mougnyan Cox
    Neda Sedora-Roman
    Srirajkumar Ranganathan
    Robert Hurst
    Bryan Pukenas
    CardioVascular and Interventional Radiology, 2022, 45 : 134 - 136
  • [23] SPATIALLY VARYING RIEMANNIAN ELASTICITY REGULARIZATION: APPLICATION TO THORACIC CT REGISTRATION IN IMAGE-GUIDED RADIOTHERAPY
    Bjerre, T.
    Fogtmann, M. O.
    Aznar, M.
    af Rosenschoeld, P. Munck
    Specht, L.
    Larsen, R.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1224 - 1227
  • [24] Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CT
    Zucca, Sergio
    Carau, Barbara
    Solla, Ignazio
    Garibaldi, Elisabetta
    Farace, Paolo
    Lay, Giancarlo
    Meleddu, Gianfranco
    Gabriele, Pietro
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 473 - 478
  • [25] Clinical introduction of image-guided radiotherapy, IGRT with cone beam CT
    Sorcini, B
    Odh, R
    Näfstadius, P
    Näslund, I
    Wersäll, P
    Tilikidis, A
    Severin, AC
    Isoz, A
    Fjällman, P
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S103 - S103
  • [26] Low-Dose Techniques in CT-guided Interventions
    Sarti, Marc
    Brehmer, William P.
    Gay, Spencer B.
    RADIOGRAPHICS, 2012, 32 (04) : 1109 - +
  • [27] Personalized organ dose assessment of cone-beam CT imaging for image-guided thoracic radiotherapy
    Zhang, Y.
    Wu, H.
    Chen, Z.
    Knisely, J.
    Nath, R.
    Feng, Z.
    Bao, S.
    Deng, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S266 - S266
  • [28] An efficient low-dose CT reconstruction technique using partial derivatives based guided image filter
    Pathak, Yadunath
    Arya, K. V.
    Tiwari, Shailendra
    MULTIMEDIA TOOLS AND APPLICATIONS, 2019, 78 (11) : 14733 - 14752
  • [29] An efficient low-dose CT reconstruction technique using partial derivatives based guided image filter
    Yadunath Pathak
    K. V. Arya
    Shailendra Tiwari
    Multimedia Tools and Applications, 2019, 78 : 14733 - 14752
  • [30] Investigation of the radiation dose from cone-beam CT for image-guided radiotherapy: A comparison of methodologies
    Buckley, Jarryd G.
    Wilkinson, Dean
    Malaroda, Alessandra
    Metcalfe, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 174 - 183