Application of low-dose CT in image-guided radiotherapy based on CT-linac

被引:0
|
作者
Yang, Jingru [1 ]
Liang, Yongguang [1 ]
Yang, Bo [1 ]
Zhang, Wenjun [1 ]
Leng, Lingxuan [1 ]
Wang, Jiaxin [1 ]
Zhu, Heling [1 ]
He, Shumeng [2 ]
Liao, Can [3 ]
Qiu, Jie [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Radiat Oncol, Beijing, Peoples R China
[2] United Imaging Res Inst Intelligent Imaging, Beijing 100094, Peoples R China
[3] Shanghai United Imaging Healthcare Co Ltd, Shanghai 201807, Peoples R China
关键词
Fan-beam CT; Image-guided radiotherapy; Low-dose CT; Image quality; ITERATIVE RECONSTRUCTION;
D O I
10.1016/j.jrras.2024.101034
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Image-guided radiation therapy (IGRT) involves online medical imaging systems. CT-guided imaging systems not only have high image quality but also allow for direct dose calculation for radiation treatment planning, making it an ideal image guidance method. However, the imaging dose from CT images may pose additional risks to patients. Therefore, the aim of this study was to evaluate the substitutability of using low-dose CT images for IGRT. Materials and methods: The CIRS-062 phantom, Catphan 604 phantom, CT dose index phantom were used to obtain the conversion curves of the CT values to the relative electron density (RED), image quality, and imaging dose of the low-dose CT, respectively. Catphan 604 phantom and clinical cases were used to analyze the feasibility of low-dose CT for dose calculation. Results: No significant differences were observed in the conversion curves of CT values to RED between low-dose and standard-dose CT scans. In terms of image quality, the geometric distortion of low-dose CT was 0.1 mm, which was the same as that of standard-dose CT. The spatial resolution of the images was 0.42-0.45 lp/mm, which was slightly better than that of standard-dose CT (0.40-0.44 lp/mm). The image uniformity was 98.4%- 99.0%, slightly worse than that of standard-dose CT (99.4%-99.5%), but still met the clinical requirements. The imaging dose was 2.96-4.62 mGy, significantly lower than that of standard-dose CT (9.71-26.68 mGy), especially for head CT protocol. In terms of dose calculation, the gamma passing rates were not lower than 98% for either the Catphan 604 phantom or the clinical cases. Conclusion: Low-dose CT can significantly reduce the imaging dose without a significant loss of image quality and can be directly used for dose calculation in radiation treatment planning, providing a safer and more effective image guidance method for IGRT.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Investigation of uncertainties in image registration of cone beam CT to CT on an image-guided radiotherapy system
    Sykes, J. R.
    Brettle, D. S.
    Magee, D. R.
    Thwaites, D. I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (24): : 7263 - 7283
  • [12] Feasability Study of Low-dose Intra-operative Cone-beam CT for Image-guided Surgery
    Han, Xiao
    Shi, Shuanghe
    Bian, Junguo
    Helm, Patrick
    Sidky, Emil Y.
    Pan, Xiaochuan
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [13] Phantom validation of coregistration of PET and CT for image-guided radiotherapy
    Lavely, WC
    Scarfone, C
    Cevikalp, H
    Li, R
    Byrne, DW
    Cmelak, AJ
    Dawant, B
    Price, RR
    Hallahan, DE
    Fitzpatrick, JM
    MEDICAL PHYSICS, 2004, 31 (05) : 1083 - 1092
  • [14] Investigation of linac-based image-guided hypofractionated prostate radiotherapy
    Pawlicki, Todd
    Kim, Gwe-Ya
    Hsu, Annie
    Cotrutz, Cristian
    Boyer, Arthur L.
    Xing, Lei
    King, Christopher R.
    Luxton, Gary
    MEDICAL DOSIMETRY, 2007, 32 (02) : 71 - 79
  • [15] Image-guided radiotherapy workflow for dose based patient verification using cone-beam CT scans
    Marchant, T.
    Moore, C.
    Rowbottom, C.
    MacKay, R.
    Williams, P.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S172 - S172
  • [16] An image-based approach to low-dose CT simulation
    Kim, Chang Won
    Kim, Jong Hyo
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [17] Application of dose compensation in image-guided radiotherapy of prostate cancer
    Wu, QW
    Liang, J
    Yan, D
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : 1405 - 1419
  • [18] Dose verification for image-guided radiotherapy
    Kapatoes, J
    Ruchala, K
    Olivera, G
    Forrest, L
    Turek, M
    Mackie, T
    Welsh, J
    Jaradat, H
    Balog, J
    Lu, W
    Jeraj, R
    Reckwerdt, P
    MEDICAL PHYSICS, 2003, 30 (06) : 1418 - 1419
  • [19] Low dose cone beam CT protocols for image-guided breast and pediatric treatments
    Falk, M.
    Vorbau, R.
    Westermark, M.
    Hulthen, M.
    Gagliardi, G.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1391 - S1392
  • [20] From image-guided radiotherapy to dose-guided radiotherapy
    Cazoulat, G.
    Lesaunier, M.
    Simon, A.
    Haigron, P.
    Acosta, O.
    Louvel, G.
    Lafond, C.
    Chajon, E.
    Leseur, J.
    de Crevoisier, R.
    CANCER RADIOTHERAPIE, 2011, 15 (08): : 691 - 698