Image quality guided iterative reconstruction for low-dose CT based on CT image statistics

被引:5
|
作者
Duan, Jiayu [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Image Proc & Pattern Recognit, Xian 710049, Shaanxi, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 18期
基金
中国国家自然科学基金;
关键词
the regularization parameter; CT IQA; image quality guided reconstruction; REGULARIZATION PARAMETERS; FACTORIZATION; OPTIMIZATION; SURE;
D O I
10.1088/1361-6560/ac1b1b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Iterative reconstruction frameworks show predominance in low dose and incomplete data situations. In the iterative reconstruction framework, there are two components, i.e., the fidelity term aims to maintain the structure details of the reconstructed object, and the regularization term uses prior information to suppress the artifacts such as noise. A regularization parameter balances them, aiming to find a good trade-off between noise and resolution. Currently, the regularization parameters are selected as a rule of thumb or some prior knowledge assumption is required, which limits practical uses. Furthermore, the computation cost of regularization parameter selection is also heavy. In this paper, we address this problem by introducing CT image quality assessment (IQA) into the iterative reconstruction framework. Several steps are involved during the study. First, we analyze the CT image statistics using the dual dictionary (DDL) method. Regularities are observed and concluded, revealing the relationship among the regularization parameter, iterations, and CT image quality. Second, with derivation and simplification of DDL procedure, a CT IQA metric named SODVAC is designed. The SODVAC locates the optimal regularization parameter that results in the reconstructed image with distinct structures and with no noise or little noise. Thirdly, we introduce SODVAC into the iterative reconstruction framework and then propose a general image-quality-guided iterative reconstruction (QIR) framework and give a specific framework example (sQIR) by introducing SODVAC into the iterative reconstruction framework. sQIR simultaneously optimizes the reconstructed image and the regularization parameter during the iterations. Results confirm the effectiveness of the proposed method. No prior information is needed and the low computation cost are the advantages of our method compared with existing state-of-the-art L-curve and ZIP selection strategies.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Caruso, Damiano
    De Santis, Domenico
    Del Gaudio, Antonella
    Guido, Gisella
    Zerunian, Marta
    Polici, Michela
    Valanzuolo, Daniela
    Pugliese, Dominga
    Persechino, Raffaello
    Cremona, Antonio
    Barbato, Luca
    Caloisi, Andrea
    Iannicelli, Elsa
    Laghi, Andrea
    EUROPEAN RADIOLOGY, 2024, 34 (04) : 2384 - 2393
  • [32] Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality
    Rivers-Bowerman, Michael D.
    Shankar, Jai Jai Shiva
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2014, 41 (05) : 620 - 625
  • [33] MOMENTUM-NET FOR LOW-DOSE CT IMAGE RECONSTRUCTION
    Ye, Siqi
    Long, Yong
    Chun, Il Yong
    2020 54TH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS, AND COMPUTERS, 2020, : 1405 - 1409
  • [34] Low-Dose CT Image Reconstruction With a Deep Learning Prior
    Park, Hyoung Suk
    Kim, Kyungsang
    Jeon, Kiwan
    IEEE ACCESS, 2020, 8 : 158647 - 158655
  • [35] Objective assessment of image quality and dose reduction in CT iterative reconstruction
    Vaishnav, J. Y.
    Jung, W. C.
    Popescu, L. M.
    Zeng, R.
    Myers, K. J.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [36] Preliminary study of dose reduction and image quality of adult pelvic low-dose CT scan with adaptive statistical iterative reconstruction
    Li, Wei
    Zhang, Cheng-Qi
    Li, Ai-Yin
    Deng, Kai
    Shi, Hao
    ACTA RADIOLOGICA, 2015, 56 (10) : 1222 - 1229
  • [37] Clinical impact of model-based type iterative reconstruction with fast reconstruction time on image quality of low-dose screening chest CT
    Yuki, Hideaki
    Oda, Seitaro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Namimoto, Tomohiro
    Katahira, Kazuhiro
    Honda, Keiichi
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    ACTA RADIOLOGICA, 2016, 57 (03) : 295 - 302
  • [38] Iterative reconstruction of low-dose CT based on differential sparse
    Lu, Siyu
    Yang, Bo
    Xiao, Ye
    Liu, Shan
    Liu, Mingzhe
    Yin, Lirong
    Zheng, Wenfeng
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [39] Data-driven Adversarial Learning for Sinogram-based Iterative Low-Dose CT Image Reconstruction
    Vizitiu, Anamaria
    Puiu, Andrei
    Reaungamornrat, Sureerat
    Itu, Lucian Mihai
    2019 23RD INTERNATIONAL CONFERENCE ON SYSTEM THEORY, CONTROL AND COMPUTING (ICSTCC), 2019, : 668 - 674
  • [40] Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study
    Grosser, Oliver S.
    Kupitz, Dennis
    Ruf, Juri
    Czuczwara, Damian
    Steffen, Ingo G.
    Furth, Christian
    Thormann, Markus
    Loewenthal, David
    Ricke, Jens
    Amthauer, Holger
    PLOS ONE, 2015, 10 (09):