Adaptive Iterative Dose Reduction in coronary CT angiography using 320-row CT: Assessment of radiation dose reduction and image quality

被引:42
|
作者
Tomizawa, Nobuo [1 ]
Nojo, Takeshi [1 ]
Akahane, Masaaki [1 ]
Torigoe, Rumiko [2 ]
Kiryu, Shigeru [3 ]
Ohtomo, Kuni [1 ]
机构
[1] Univ Tokyo, Dept Radiol, Bunkyo Ku, Tokyo 1130033, Japan
[2] Toshiba Med Syst Corp, Tokyo Metropolitan Reg Off, Tokyo, Japan
[3] Univ Tokyo, Inst Med Sci, Dept Radiol, Tokyo, Japan
关键词
Coronary CT angiography; Effective dose; Filtered back projection; Iterative reconstruction; 320-row CT; RECONSTRUCTION;
D O I
10.1016/j.jcct.2012.02.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Several methods have been developed to reduce the radiation dose in coronary computed tomography angiography (CTA). OBJECTIVE: The objective of our study was to evaluate the effects of Adaptive Iterative Dose Reduction (MDR) on objective and subjective image quality as well as the radiation dose, compared with conventional filtered back projection (FBP), in coronary CTA. METHODS: We retrospectively reviewed 100 consecutive patients who underwent coronary CTA. En the first 50 patients, a higher tube current was used, and images were reconstructed with FBP. In the last 50 patients, a lower tube current was used, and images were reconstructed with AIM. Subjective and objective image quality (noise, signal-to-noise ratio, contrast-to-noise ratio) were assessed. RESULTS: The median radiation dose of the AIDR group was 22% lower than that of the FBP group (4.2 vs 5.4 niSv; P = 0.0001). No significant difference was found in subjective image quality, noise, signal-to-noise ratio, or contrast-to-noise ratio between the 2 groups. CONCLUSION: AIDR reduced the tube current which resulted in reduction of radiation dose in coronary CTA while maintaining subjective and objective image quality compared with coronary CTA reconstructed with FBP. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:318 / 324
页数:7
相关论文
共 50 条
  • [1] The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography
    Tatsugami, F.
    Matsuki, M.
    Nakai, G.
    Inada, Y.
    Kanazawa, S.
    Takeda, Y.
    Morita, H.
    Takada, H.
    Yoshikawa, S.
    Fukumura, K.
    Narumi, Y.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016): : E378 - E382
  • [2] The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial
    Feger, Sarah
    Rief, Matthias
    Zimmermann, Elke
    Martus, Peter
    Schuijf, Joanne Desiree
    Blobel, Jrog
    Richter, Felicitas
    Dewey, Marc
    [J]. PLOS ONE, 2015, 10 (05):
  • [3] Radiation dose for 320-row dose-modulated dynamic coronary CT angiography
    Izoe, Yukako
    Nagao, Michinobu
    Tokai, Mei
    Hashimoto, Hiroyuki
    Tanaka, Isao
    Chida, Koichi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 307 - 312
  • [4] Coronary computed tomography angiography and endocardial leads - Image quality in 320-row CT using iterative reconstruction
    Garmer, Marietta
    Bonsels, Marc
    Metz, Frauke
    Klein-Wiele, Oliver
    Brandts, Bodo
    Groenemeyer, Dietrich
    [J]. CLINICAL IMAGING, 2018, 50 : 157 - 163
  • [5] Radiation dose reduction in CT coronary angiography
    Shapiro B.P.
    Young P.M.
    Kantor B.
    Choe Y.H.
    McCollough C.H.
    Gerber T.C.
    [J]. Current Cardiology Reports, 2010, 12 (1) : 59 - 67
  • [6] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Chuanchen Zhang
    Zhaoqi Zhang
    Zixu Yan
    Lei Xu
    Wei Yu
    Rui Wang
    [J]. The International Journal of Cardiovascular Imaging, 2011, 27 : 1059 - 1068
  • [7] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Zhang, Chuanchen
    Zhang, Zhaoqi
    Yan, Zixu
    Xu, Lei
    Yu, Wei
    Wang, Rui
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07): : 1059 - 1068
  • [8] REDUCTION OF RADIATION DOSE OF 320-ROW CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY THROUGH PRIOR CORONARY CALCIUM SCANNING
    Dewey, Marc
    Zimmermann, Elke
    Wollenberg, Ulrike
    Rief, Matthias
    Greupner, Johannes
    Hamm, Bernd
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [9] Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study
    Leipsic, Jonathon
    LaBounty, Troy M.
    Heilbron, Brett
    Min, James K.
    Mancini, G. B. John
    Lin, Fay Y.
    Taylor, Carolyn
    Dunning, Allison
    Earls, James P.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 655 - 660
  • [10] Image quality and radiation dose of renal perfusion CT with low-dose contrast agent: a comparison with conventional CT using a 320-row system
    Asayama, Y.
    Nishie, A.
    Ishigami, K.
    Ushijima, Y.
    Kakihara, D.
    Fujita, N.
    Morita, K.
    Ishimatsu, K.
    Takao, S.
    Honda, H.
    [J]. CLINICAL RADIOLOGY, 2019, 74 (08) : 650.e13 - 650.e18