A novel deformable lung phantom with programably variable external and internal correlation

被引:7
|
作者
Ranjbar, Maida [1 ]
Sabouri, Pouya [1 ]
Repetto, Carlo [1 ]
Sawant, Amit [1 ]
机构
[1] Univ Maryland, Dept Radiat Oncol, Sch Med, Baltimore, MD 21201 USA
基金
美国国家卫生研究院;
关键词
deformable lung phantom; programmable; respiratory motion management; surrogate-based lung motion model; variable correlation; REAL-TIME TUMOR; RESPIRATORY MOTION; GATED RADIOTHERAPY; IMAGE REGISTRATION; QUALITY-ASSURANCE; LOCALIZATION; VERIFICATION; MOVEMENT; SYSTEM; CANCER;
D O I
10.1002/mp.13507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Lung motion phantoms used to validate radiotherapy motion management strategies have fairly simplistic designs that do not adequately capture complex phenomena observed in human respiration such as external and internal deformation, variable hysteresis and variable correlation between different parts of the thoracic anatomy. These limitations make reliable evaluation of sophisticated motion management techniques quite challenging. In this work, we present the design and implementation of a programmable, externally and internally deformable lung motion phantom that allows for a reproducible change in external-internal and internal-internal correlation of embedded markers. Methods An in-house-designed lung module, made from natural latex foam was inserted inside the outer shell of a commercially available lung phantom (RSD, Long Beach, CA, USA). Radiopaque markers were placed on the external surface and embedded into the lung module. Two independently programmable high-precision linear motion actuators were used to generate primarily anterior-posterior (AP) and primarily superior-inferior (SI) motion in a reproducible fashion in order to enable (a) variable correlation between the displacement of interior volume and the exterior surface, (b) independent changes in the amplitude of the AP and SI motions, and (c) variable hysteresis. The ability of the phantom to produce complex and variable motion accurately and reproducibly was evaluated by programming the two actuators with mathematical and patient-recorded lung tumor motion traces, and recording the trajectories of various markers using kV fluoroscopy. As an example application, the phantom was used to evaluate the performance of lung motion models constructed from kV fluoroscopy and 4DCT images. Results The phantom exhibited a high degree of reproducibility and marker motion ranges were reproducible to within 0.5 mm. Variable correlation was observed between the displacements of internal-internal and internal-external markers. The SI and AP components of motion of a specific marker had a correlation parameter that varied from -11 to 17. Monitoring a region of interest on the phantom's surface to estimate internal marker motion led to considerably lower uncertainties than when a single point was monitored. Conclusions We successfully designed and implemented a programmable, externally and internally deformable lung motion phantom that allows for a reproducible change in external-internal and internal-internal correlation of embedded markers.
引用
收藏
页码:1995 / 2005
页数:11
相关论文
共 50 条
  • [1] An Externally and Internally Deformable Lung Motion Phantom with Programmable, Variable External-Internal Correlation
    Ranjbar, M.
    Sabouri, P.
    Repetto, C.
    Sawant, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E661 - E661
  • [2] Development of a deformable lung phantom for the evaluation of deformable registration
    Chang, Jina
    Suh, Tae-Suk
    Lee, Dong-Soo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 281 - 286
  • [3] Development of a Deformable Lung Phantom for the Evaluation of Deformable Registration
    Chang, J.
    Suh, T.
    Lee, D.
    Cho, G.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [4] Development of a Deformable Lung Phantom for the Evaluation of Deformable Registration
    Chang, J.
    Lee, D.
    Suh, T.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 635 - 637
  • [5] A novel deformable lung phantom for 4D radiotherapy verification
    Margeanu, M.
    Stroian, G.
    Heath, E.
    Seuntjens, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2649 - 2649
  • [6] Development of An Anthropomorphic Deformable Lung Phantom
    Shin, D.
    Kang, S.
    Kim, K.
    Kim, T.
    Kim, D.
    Yoon, D.
    Yamamoto, T.
    Suh, T.
    MEDICAL PHYSICS, 2017, 44 (06) : 3300 - 3300
  • [7] A Novel Abdominal Phantom with Deformable Organs
    Maldonado, C.
    Wang, G.
    Min, G.
    Faruquee, S.
    Huff, G.
    Dean, J.
    Brown, K.
    Buchsbaum, W.
    Yadav, P.
    O'Neill, D.
    MEDICAL PHYSICS, 2024, 51 (10) : 7970 - 7970
  • [8] Evaluation of tumour motion and internal/external correlation in lung SABR
    Ali, Asmaa M.
    Greenwood, Jason B.
    Walls, Gerard M.
    Belshaw, Louise
    Agnew, Christina E.
    Mcaleese, Jonathan
    Whitten, Glenn
    Irvine, Denise M.
    Hounsell, Alan R.
    Mcgarry, Conor K.
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1149):
  • [9] An externally and internally deformable, programmable lung motion phantom
    Cheung, Yam
    Sawant, Amit
    MEDICAL PHYSICS, 2015, 42 (05) : 2585 - 2593
  • [10] ON THE CORRELATION OF INTERNAL AND EXTERNAL IN PSYCHOLOGY
    CHUDNOVSKY, VE
    PSIKHOLOGICHESKII ZHURNAL, 1993, 14 (05) : 3 - 12