Development of a Deformable Lung Phantom for the Evaluation of Deformable Registration

被引:0
|
作者
Chang, J. [1 ]
Lee, D. [2 ]
Suh, T. [1 ]
机构
[1] Catholic Univ, Coll Med, Dept Biomed Engn, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Nucl Med, Seoul 110744, South Korea
关键词
Deformable phantom; Deformable registration algorithm; Evaluation; TECHNICAL NOTE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to develop a deformable lung phantom prototype for the evaluation of a deformable image registration algorithm. The phantom consisted of an acryl cylinder filled with water and a latex balloon located in the inner space of the cylinder. This latex balloon simulated the thoracic cavity, and it was filled with sponges and targets, which were embedded in the sponges. A silicon membrane was attached to the inferior end of the phantom. The silicon membrane was designed to simulate a real lung diaphragm and to reduce motor workload. This specific design was able to reduce the motor size of the phantom. Verification of deformable registration was based on peak exhale and peak inhale breathing phases. The isocenters of the targets on the Coreplan radiation planning system (Seoul C&J, KR) were compared for quantitative registration evaluation. The registration differences ranged from 0.85 mm to 1.47 mm, and accuracy was determined according to target deformation. This phantom was able to simulate the features and deformation of real human lung and has the potential for wide application in 4D treatment planning.
引用
收藏
页码:635 / 637
页数:3
相关论文
共 50 条
  • [1] Development of a deformable lung phantom for the evaluation of deformable registration
    Chang, Jina
    Suh, Tae-Suk
    Lee, Dong-Soo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 281 - 286
  • [2] Development of a Deformable Lung Phantom for the Evaluation of Deformable Registration
    Chang, J.
    Suh, T.
    Lee, D.
    Cho, G.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Development of An Anthropomorphic Deformable Lung Phantom
    Shin, D.
    Kang, S.
    Kim, K.
    Kim, T.
    Kim, D.
    Yoon, D.
    Yamamoto, T.
    Suh, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3300 - 3300
  • [4] Development of a dynamic deformable thorax phantom for the quality management of deformable image registration
    Sugawara, Yasuharu
    Kadoya, Noriyuki
    Kotabe, Kazuki
    Nakajima, Yujiro
    Ikeda, Ryutaro
    Tanabe, Shunpei
    Ohashi, Haruna
    Jingu, Keiichi
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 100 - 107
  • [5] Evaluation of the accuracy of deformable image registration on MRI with a physical phantom
    Wu, Richard Y.
    Liu, Amy Y.
    Yang, Jinzhong
    Williamson, Tyler D.
    Wisdom, Paul G.
    Bronk, Lawrence
    Gao, Song
    Grosshan, David R.
    Fuller, David C.
    Gunn, Gary B.
    Ronald Zhu, X.
    Frank, Steven J.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 166 - 173
  • [6] Comparison of two deformable registration software using an in-house "deformable phantom"
    Koutsouvelis, N.
    Rouzaud, M.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 838 - 839
  • [7] An Anthropopathic Deformable Phantom for Geometric and Dose Accumulation Accuracy Validation of Deformable Image Registration
    Liao, Y.
    Chen, H.
    Chen, J.
    Gu, X.
    Zhen, X.
    Zhou, L.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3884 - 3884
  • [8] A Three-Dimensional Thermoplastic Prostate Phantom for Evaluation of Deformable Image Registration
    Reber, C.
    Neo, A.
    Schoenhoff, E.
    Kirby, N.
    Singhrao, K.
    Pouliot, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Evaluation of Diffeomorphic Demons Algorithm for Deformable Image Registration Using Virtual Phantom
    Reiazi, R.
    Mohammadi, R.
    Mahdavi, S. R.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228
  • [10] Intra and Intermodality Validation of Registration Algorithms On a Deformable Phantom
    Vincent, S. D.
    Archambault, L.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)